Search:

Type: Posts; User: EjBreeze

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Compressors on roofs or steamer boiler tanks. ...

    Compressors on roofs or steamer boiler tanks. They all make you feel old.
  2. Replies
    13
    Views
    3,086

    Yes exactly. Have you ever been on a cruise ship...

    Yes exactly. Have you ever been on a cruise ship standing in line to toast your bagel with three lines on the card? It's painful.
  3. Replies
    13
    Views
    3,086

    Pop ups are slow. I would look towards...

    Pop ups are slow. I would look towards Toastmaster or Hobart for the highest wattage available. Anything else is for home use. The number of element card lines will set the toast time.
  4. Replies
    13
    Views
    3,086

    If your talking a conveyor toaster which Holman...

    If your talking a conveyor toaster which Holman makes I would prefer a Savory or a Hatco. Why mess with glass elements?
  5. Replies
    18
    Views
    1,558

    Crimp a stainless connector of your choice on the...

    Crimp a stainless connector of your choice on the end with a proper crimper. Been doing it for 30 years. Just fixed one the other day I crimped 15 years ago :)
  6. Replies
    13
    Views
    3,086

    Actually they are at the low end of the appliance...

    Actually they are at the low end of the appliance chain. Many items they sell parts are not available.
  7. Replies
    13
    Views
    3,086

    Waring is a throw away product. They have no...

    Waring is a throw away product. They have no purpose in a commercial kitchen.
  8. Replies
    18
    Views
    1,558

    No I usually crimp a connector to the end. Works...

    No I usually crimp a connector to the end. Works the same.
  9. Replies
    14
    Views
    1,006

    I would check from the love joy on up. If the...

    I would check from the love joy on up. If the bearing assy going through the bottom of the machine is not true then it will do this.
  10. Replies
    1
    Views
    1,064

    Is the thermostat cycling off at 325 degrees? I...

    Is the thermostat cycling off at 325 degrees? I don't see any Magic Chefs in commercial kitchens so not sure of the controls. If it is a kx thermostat with the center screw then you should be able...
  11. Replies
    41
    Views
    15,352

    You my man should work for yourself. You will...

    You my man should work for yourself. You will blow the competition away. This is the way I have been running my business for 23 years. Try asking a Hobart, GCS, or a Service Solutions man to...
  12. Replies
    24
    Views
    7,085

    Good techs don't replace part after part until...

    Good techs don't replace part after part until they find the problem. There are exceptions but a filter ain't one of them.
  13. Replies
    4
    Views
    1,835

    It depends if the frame of the ceramic burner got...

    It depends if the frame of the ceramic burner got torched/welded to the receiver slide of the fry tank. You will need to remove the blower fan and the insulation and blower box that you see in front...
  14. Replies
    5
    Views
    2,523

    For others that is a TS valve with pilot in/out. ...

    For others that is a TS valve with pilot in/out. You just need to know your two inlet /outlet sizes. The pilot comes in both 1/8 or 1/4 inch. The main line can be several different sizes.
  15. Replies
    2
    Views
    1,622

    This should be fairly easy to identify. Follow...

    This should be fairly easy to identify. Follow the cord to the terminal block and check your voltage from the cord. Now check your voltage at the outlet. They should be the same. If they are...
  16. Replies
    24
    Views
    7,085

    After you slide your pan over the inlet where the...

    After you slide your pan over the inlet where the two o-rings are take some saran wrap and wrap the inlet connection good and tight. Now try it.
  17. Replies
    24
    Views
    7,085

    Place your finger on the pickup and see if your...

    Place your finger on the pickup and see if your getting suction. This should tell you if the problem is in the pan/pickup or the motor/return lines.
  18. Replies
    5
    Views
    2,005

    If your going to replumb it then why not place...

    If your going to replumb it then why not place clean out ports where you can snake out the drain when it gets plugged.
  19. Thread: southbend

    by EjBreeze
    Replies
    4
    Views
    2,186

    Replace the module with the new style fenwall...

    Replace the module with the new style fenwall module has worked well for me.
  20. Replies
    2
    Views
    1,432

    http://berkelsalesservice.com/PDFs/PM20.pdf

    http://berkelsalesservice.com/PDFs/PM20.pdf
  21. Replies
    2
    Views
    1,278

    Make sure your pilot flame is proper size and the...

    Make sure your pilot flame is proper size and the electrode wire connectors are clean and secure.
  22. Replies
    6
    Views
    2,824

    The "p" is for pilot adjustment which you are not...

    The "p" is for pilot adjustment which you are not using. "B" is for BYPASS (MINIMUM BURNER FLAME) ADJUSTMENT. Check to see on the side what type of FD valve you have. I have seen some FD valves...
  23. Replies
    6
    Views
    2,824

    If you have a bypass screw adjustment on that...

    If you have a bypass screw adjustment on that thermostat check to see if it is set to wide open.

    http://www.icca.invensys.com/uniline/e/e38.pdf
  24. Replies
    14
    Views
    3,545

    You need to identify were the problem is. You...

    You need to identify were the problem is. You have looked at the obvious. This will tell you what direction the problem lies.
  25. Replies
    14
    Views
    3,545

    When you had the regulator off did you open up...

    When you had the regulator off did you open up the water line to visually inspect the flow?
  26. Replies
    14
    Views
    3,545

    I don't think you have a pressure problem rather...

    I don't think you have a pressure problem rather a flow problem since your static pressure after the regulator is reading 25 psi. I think I would want to start removing these fittings to see what is...
  27. Replies
    14
    Views
    3,545

    Did you check the line strainer or any check...

    Did you check the line strainer or any check valves inline with the solenoid? Have you taken the solenoid apart to check scale/dirt conditions?
  28. Replies
    14
    Views
    3,545

    Your description sounds like a classic failing...

    Your description sounds like a classic failing regulator. The flow is reduced from usually scale build up and dirt.
  29. Thread: Yellow Flames

    by EjBreeze
    Replies
    12
    Views
    3,632

    Poor air to gas ratio (not enough air mixed with...

    Poor air to gas ratio (not enough air mixed with gas for complete combustion of fuel)
    Dirt, rust, dust,grease, (any obstruction that has restricted the venturi section of your burner where air and...
  30. Replies
    2
    Views
    2,152

    Check the stop switch to make sure it is N/C.

    Check the stop switch to make sure it is N/C.
  31. Nalco announces merger agreement with Ecolab

    Nalco has announced that it will be merging with Ecolab, a provider of cleaning, sanitising, food safety and infection prevention products and services.

    The agreement has been unanimously ratified...
  32. Replies
    5
    Views
    2,257

    Good job! You had me thinking they were stating...

    Good job! You had me thinking they were stating to make throw away equipment :)
  33. Replies
    5
    Views
    2,257

    The 3646410 is thermostatic controlled. The...

    The 3646410 is thermostatic controlled. The 36464 is infinite switch controlled. Does the ball valve screwed on at the bottom hold the out cover on? If it becomes to much of a hassle you can...
  34. Replies
    4
    Views
    1,778

    Why not just change the regulator part of the...

    Why not just change the regulator part of the valve. Check with Allpoints. It should only be a few dollars.
  35. What parts? Float assy or relay?

    What parts? Float assy or relay?
  36. It sounds like someone converted it. The float...

    It sounds like someone converted it. The float controls water and heat. The pair of black wires coming out of it is the bottom float that is normally open. The pair of red wires is the upper float...
  37. Replies
    12
    Views
    4,453

    X2, But if you want replace the thermostat,...

    X2, But if you want replace the thermostat, high limit, and gas valve
  38. Thread: hobart parts

    by EjBreeze
    Replies
    27
    Views
    7,895

    If your walking up to the parts counter ask to...

    If your walking up to the parts counter ask to see their manual of the model you are working on. If they give you that look or sigh when you ask then ask for the parts manager. That's what I do and...
  39. Replies
    5
    Views
    2,919

    Those pilot heads needs to be super hot with a...

    Those pilot heads needs to be super hot with a red glow to make the pilot safety stay open. In the past I have tried cleaning out the orifice with no luck. Blue burns isn't hot enough. Replace the...
  40. I never have liked fryer modules or built in...

    I never have liked fryer modules or built in pumps. They are a grease catcher and a PIA to work on. If for some reason the customer has to buy a new fryer then they must replace the whole unit. ...
  41. Replies
    28
    Views
    7,702

    So you don't work on electrics? You have never...

    So you don't work on electrics? You have never seen a older frymaster, annets, dean wired this way? Never came across a missed wired fryer? I have never assumed anything when working on a piece of...
  42. Replies
    28
    Views
    7,702

    Hi hope you checked the hi limit is wired into...

    Hi hope you checked the hi limit is wired into the pilot circuit and not inline with the thermostat. Been a pro....25 years and 6 figures.
  43. Replies
    28
    Views
    7,702

    Again how would that test a hi limit that fails...

    Again how would that test a hi limit that fails at lets say 300 degrees?
  44. Replies
    28
    Views
    7,702

    Why would you jump out the hi limit? I would...

    Why would you jump out the hi limit? I would want to see if it is failing at a lower temp also. As long as it doesn't fail under the highest setting on the tstat then what is the point?
  45. Replies
    28
    Views
    7,702

    It was a millivolt control fryer. If the pilot...

    It was a millivolt control fryer. If the pilot isn't strong enough to heat up the thermopile to generate the proper millivolt to open the gas valve then it will not work but will still keep the...
  46. Replies
    11
    Views
    2,874

    You can start both ovens up at the same time and...

    You can start both ovens up at the same time and observe which oven cycles off first. Having two temp meters makes this fairly simple. If the slower oven doesn't cycle off close to the other I would...
  47. Thread: hobart parts

    by EjBreeze
    Replies
    27
    Views
    7,895

    What discounts off list are you seeing?

    What discounts off list are you seeing?
  48. Replies
    7
    Views
    3,912

    You will want to start out with the schematic for...

    You will want to start out with the schematic for the Liquid Level Board . That will give you the wiring for your fill solenoid, low water light if you have one and pass the control circuit voltage...
  49. Thread: cooking

    by EjBreeze
    Replies
    18
    Views
    2,687

    Look at drawing number 105881. Most likely your...

    Look at drawing number 105881. Most likely your problem is here.

    http://www.clevelandrange.com/docs/uploaded/cle/CRManuals/24CGA10_Parts.pdf
  50. Replies
    6
    Views
    2,910

    The way I handle these mixers is to have a parts...

    The way I handle these mixers is to have a parts breakdown on hand and remove piece by piece in order unless you can obviously see the problem.
Results 1 to 50 of 56
Page 1 of 2 1 2