Search:

Type: Posts; User: mujtaba12

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    15
    Views
    2,626

    I will see if I can find one for you...

    I will see if I can find one for you...
  2. Replies
    0
    Views
    415

    Trane Bacnet Integration

    Hi Guys,

    I would really appreciate help if somebody can help me with the trane sequence. I successfully integrated that trane unit BCI-R controller to my system over bacnet MSTP I just need a help...
  3. Replies
    7
    Views
    909

    Series and Parallel FBP

    Does anyone know the difference between seies and parallel fan powered vav box its disadvantages/advantages and control strategy as well...thanks in advance
  4. Replies
    0
    Views
    373

    Satchwell Touchscreen

    Have anyone has worked on Satchwell touchscreen.. I need to know if I need to configure its points..


    Thanks

    Mujtaba
  5. Replies
    18
    Views
    1,400

    I would suggest try by changing different baud...

    I would suggest try by changing different baud rates while connecting through serial tunneling may be 1200 or 2400.. I have had this problem but make sure your ASD is ok..
  6. Replies
    4
    Views
    1,365

    control men do u have anyidea from where I can...

    control men do u have anyidea from where I can downlaod its setup file obviously I have to purchase a license then for working with the controllers...
  7. Replies
    4
    Views
    1,365

    hi, really thanks for the reply actually I am...

    hi,
    really thanks for the reply

    actually I am stuck with the integration of satchwell touch screen ''MN 50 TSP LON'' I have commissioned the device with unc-520 in Niagara r2 but I am not been...
  8. Replies
    4
    Views
    1,365

    VisiSat Satechwell software

    Does anyone know form where I can get visisat software from satchwell....
  9. Replies
    0
    Views
    327

    MN-50-TSP-Lon from satchwel

    Hi,

    I need help in for commissiong of MN50 tsp lon device. How I have to configure the snvts and how we have set its display..thanks in advance..
  10. from the version u have installed th os in unc

    from the version u have installed th os in unc
  11. goto service...then right click on lonworks...

    goto service...then right click on lonworks services to the lon device manager....then there will be a local lon device at the top..just goto properties of that device and assign the neuron id...
  12. the impedance is 150 ohm if we switched to ma...

    the impedance is 150 ohm if we switched to ma...
  13. Its a tac humidity sensor.. I dont know its...

    Its a tac humidity sensor.. I dont know its impedance
  14. ok suppose if I need 0-10 vdc to 0-20ma then what...

    ok suppose if I need 0-10 vdc to 0-20ma then what can I do??[QUOTE=BACnet;11271172]It's a whole lot easier to convert a current to a voltage than it is the other way around.

    It would seem that you...
  15. cant we achieve this by using a simple...

    cant we achieve this by using a simple resistance??in series or in parallel??
  16. how we have to connect parralel to the volatage...

    how we have to connect parralel to the volatage terminal coming out from the transducer..normally we have a 4-20 ma signal and if we need to convert it to voltage we use 500 ohm resistance in...
  17. only 4-20 ma signal

    only 4-20 ma signal
  18. converting 0-10 vdc signal to 4-20 ma signal

    Hi,

    I need to ask if some one has ever converted 0-10vdc signal to 4-20 ma signal.. has anybody tried this my sensor is giving 0-10 vdc output but my controller accepts 4-20 ma signal...
  19. Replies
    3
    Views
    1,151

    if you can please also share some knowledge about...

    if you can please also share some knowledge about staircase pressurization as well the manuals are very useful which u shared
  20. Replies
    3
    Views
    1,151

    Concepts of DCV

    What are the concepts of demand control ventilation??
  21. Replies
    0
    Views
    432

    Venturi Valve

    If any one could help me in venturie valve connections with fume hood monitor...the manuals are attached.. I have done the same as described in page 4 of accel valve literature.. The literautre for...
  22. Replies
    2
    Views
    451

    RS-485 Modbus address list

    I require mod bus address list for multitek 550...If anyone can provide me
  23. Replies
    6
    Views
    2,820

    give me ur e-mail address..I will send u the...

    give me ur e-mail address..I will send u the manuals..I dnt know y people ask for the charges just for the manuals...
  24. Replies
    20
    Views
    2,002

    I think we are here to share the knowledge and to...

    I think we are here to share the knowledge and to help each other I dont know why did you think in that way..anyways if u not wish to tell then u r not allowed to comment actually
  25. Replies
    20
    Views
    2,002

    still waiting...u have to ask with ur experts

    still waiting...u have to ask with ur experts
Results 1 to 25 of 175