  1. make sense!

    make sense!
  2. Replies
    8
    Views
    745

    Why they cut it?it realy look like same size pipe...

    Why they cut it?it realy look like same size pipe to me,just have to make 90 turn to angel it need ?
  3. Replies
    8
    Views
    745

    Wow!somebody must point a gun to they head make...

    Wow!somebody must point a gun to they head make them rush to finish that job,Ray Charles can do better then that!as far as flu air flow concern,somebody have better knowledge can help u with that!i...
  4. Replies
    17
    Views
    1,003

    Ur second tech sounds like he got some...

    Ur second tech sounds like he got some knowledge,but he make the wrong choice mess around other things,he should replace txv and drier first and check liquid line restriction with pressure u...
  5. why manufactury get cheaper copper product save...

    why manufactury get cheaper copper product save tons of money,but our equipment price still keep going up each year???
  6. when u measure the current must measure one to...

    when u measure the current must measure one to common another to terminal u want to check to get voltage reading !
  7. Replies
    140
    Views
    6,398

    Sorry didnt read the long post,condenser can be...

    Sorry didnt read the long post,condenser can be 13 seer with variable speed air handler make it 14 seer!hope i am correct!
  8. Replies
    17
    Views
    822

    extent lineset and voltage wires,done!

    extent lineset and voltage wires,done!
  9. Thread: Makes it rough

    by pony
    Replies
    5
    Views
    378

    It happen to most peoples,supply house worker can...

    It happen to most peoples,supply house worker can make mistake also,and i know they mistake allways cost us money and labor,not blaming them make mistake,but blaming them knowing they made a mistake...
  10. Replies
    15
    Views
    1,927

    More freon!

    More freon!
  11. Thread: X13 motors

    by pony
    Replies
    23
    Views
    10,095

    What about lennox CBX27 x13 motor,heard anything...

    What about lennox CBX27 x13 motor,heard anything bad about it?
  12. Old evap coil with r410a pressure,i rather go...

    Old evap coil with r410a pressure,i rather go with lower pressure r22 unit!
  13. Like to try it one day in tight spot!

    Like to try it one day in tight spot!
  14. Replies
    19
    Views
    1,478

    Dont worry!u will get better !

    Dont worry!u will get better !
  15. Replies
    10
    Views
    819

    I usually tell then it take little time to...

    I usually tell then it take little time to circlaire the hot air out before they even open they mouth after i fix it!Lol!i would said about 99% of the customer can feel the cold air cause they have...
  16. Replies
    20
    Views
    745

    if u have proper charge SC should be around...

    if u have proper charge SC should be around 10-12F,do u?
  17. Replies
    20
    Views
    745

    what is SC?

    what is SC?
  18. Thread: what's going on?

    by pony
    Replies
    9
    Views
    594

    sounds like restriction!

    sounds like restriction!
  19. Replies
    140
    Views
    6,398

    Why discontinue dry R22?they are few r22...

    Why discontinue dry R22?they are few r22 replacement refrigerant ozone friendly can put in R22 unit?if goverment concern about seer rating,txv or X13 motor will increase seer rating maybe even 1/2...
  20. Replies
    56
    Views
    2,093

    Mr Udarrell,honor be on the same post with u,read...

    Mr Udarrell,honor be on the same post with u,read a lots of ur online hvac trouble shooting information back when i first start this line of work,thank u!
  21. Replies
    56
    Views
    2,093

    How do u get refrigerant out before u change coil...

    How do u get refrigerant out before u change coil and condenser?if u change wrong indoor coil,u will find out real quick with refrigerant all over ur face when u cut the cooper line indoor coil?so it...
  22. Thread: "A" coil sideways

    by pony
    Replies
    14
    Views
    639

    up and down flow coil ok sideway if u have...

    up and down flow coil ok sideway if u have to,horizontal coil dont think have drain pan on side,so have to install drain pan on the bottom!
  23. Replies
    29
    Views
    1,145

    bad board will be my first guess!

    bad board will be my first guess!
  24. Thread: Bryant txv

    by pony
    Replies
    188
    Views
    14,646

    Not big fan of txv valve just like ECM motor,to...

    Not big fan of txv valve just like ECM motor,to many fail for different reason,if u install by the book,purge nitro while braze,dons't mean txv not goona mulfuction !cost more money for customer and ...
  25. If i am not mistaken,u r talking about use...

    If i am not mistaken,u r talking about use manifold gauge bring refrigerant from highside to low side cause ur txv was bad clogged?it is good idea ,but first verify the txv is clogged,hook u gauge...