03-25-2010, 04:54 AM
Thread: flaring/swival Tee on 410a?
by harley91- Replies
- 2
- Views
- 357
Thank You So Much Have A Great Day
Thank You So Much Have A Great Day
-
03-24-2010, 05:58 PM
Thread: flaring/swival Tee on 410a?
by harley91- Replies
- 2
- Views
- 357
flaring/swival Tee on 410a?
Have not worked on many 410a systems,Need to know if you can use a swival tee or is this a no no?And can you use flare fittingsin the high /low lines.have to install a water regulator,Johnson V246,No...
-
02-27-2010, 08:29 AM
Thread: York ZB4K1 compressor Torque specs?
by harley91- Replies
- 1
- Views
- 843
York ZB4K1 compressor Torque specs?
Does anyone out there have the compressor Torque specs and clearances on a york ZB4K1 compressor? Thanks
-
01-19-2010, 05:09 PM
Thread: Can't Humidity UP problem
by harley91- Replies
- 11
- Views
- 528
Can't Humidity UP problem
Have a 2850 sf 3 year old house,Installed a 9 gal per day true steam Humidifier,started up ,Running now for 3 weeks .Humidistat set at 40% can only get house to 32% out side temp between 10 and...
-
08-27-2009, 06:14 AM
- Replies
- 7
- Views
- 858
Evacuation on chiller/Vac drops with pump off
Hi
had a situation ,pulled vac on centrifugal [no R11 in system]pulled down to 26 in ".Used 3 vac pumps.felt presure comming out of pumps,isolated pumps turned off pumps ,let sit ,had thermal... -
07-16-2009, 05:41 AM
Thread: Bad Suction Accumulator
by harley91- Replies
- 7
- Views
- 1,106
Bad Suction Accumulator
Has Anyone come acoss a bad suction accumulator? Not sure what can go wrong,Have a small chiller ,Floading back,low low load ,has accumulator,R22,suction 20lb,low temp compresor discus.Want to know...
-
05-03-2009, 08:45 AM
Thread: Sniffer for chiller bundle with glycal?
by harley91- Replies
- 7
- Views
- 603
Thanks,You guys are GREAT
Time to buy a Halide
-
05-01-2009, 06:29 PM
Thread: Sniffer for chiller bundle with glycal?
by harley91- Replies
- 7
- Views
- 603
Sniffer for chiller bundle with glycal?
I think I may have a leaking tube in a small chiller ,The water has glycal mix,I was told electronic detectors pick up glycal,is this true? If so what would you use to sniff for R22?
... -
04-19-2009, 07:50 AM
Thread: RTAA Chiller-270/370 Question (100*sec)
by harley91- Replies
- 4
- Views
- 388
RTAA Chiller-270/370 Question (100*sec)
What it definition of term - 100*seconds
If entering water temp drops 2* below leaving water temp for more than 100* seconds - indicates loss of water through chiller evap.Thanks -
04-18-2009, 09:03 AM
Thread: Sanyo split problem with [temp control]
by harley91- Replies
- 1
- Views
- 319
Sanyo split problem with [temp control]
Have a older sanyo split M#ch182 The temp is over shooting set set point [will not shut off]-you can shut unit off and on through remote.but remote will not auto turn off unit at setpoint. you must...
-
04-13-2009, 06:15 AM
Thread: Tube Supports York YSDC Screw
by harley91- Replies
- 7
- Views
- 493
Hay guys I got the manual on machine from york, ...
Hay guys I got the manual on machine from york, Cooler -Horizontal,flooded,shell and tube type,distrabution system consisting of -distribution trugh to give uniform distrabution throughout the shell...
-
04-09-2009, 05:48 AM
Thread: Tube Supports York YSDC Screw
by harley91- Replies
- 7
- Views
- 493
Thanks Klove
Thanks Klove
-
04-08-2009, 08:58 PM
Thread: Tube Supports York YSDC Screw
by harley91- Replies
- 7
- Views
- 493
Tube Supports York YSDC Screw
Does anyone know what the tube supports in the cooler and the condenser are made of are M#YSDCDBS3-CMCS?Thanks
-
04-06-2009, 08:57 PM
- Replies
- 11
- Views
- 912
HI GRAHAM
Thank you very much ,That was a...
HI GRAHAM
Thank you very much ,That was a wonderfull Explanation.Sounds like that would be the best way to make shure its right.Thanks again -
04-06-2009, 07:22 PM
- Replies
- 11
- Views
- 912
Thanks for the input chillr dude.That helps
Thanks for the input chillr dude.That helps
-
04-06-2009, 07:20 PM
- Replies
- 11
- Views
- 912
Hi graham
Thanks for your inpute!
With out...
Hi graham
Thanks for your inpute!
With out writing a book,I do know about moisture in the system and megging,Im not asking about any clean up issues.Ive cleaned up many systems ! I try to do things... -
04-06-2009, 05:57 AM
- Replies
- 11
- Views
- 912
The oil tested low acidic,and it looks...
The oil tested low acidic,and it looks dirty,sight glass is still green.I am megging motors This is a prosses chiller Cant Leave off long,trying to buy time.
-
04-06-2009, 05:28 AM
- Replies
- 11
- Views
- 912
RTAA screw Chiller-Changing oil & filters
Does anyone have steps on changing oil on RTAA 370 air cooled screws-The book does not have info.
Anyone done it out there?Thanks -
04-04-2009, 12:57 PM
Thread: Obama haters need not respond
by harley91- Replies
- 312
- Views
- 7,280
new member having trouble postin question can you...
new member having trouble postin question can you help harley91
Results 1 to 19 of 23