Search:
Type: Posts; User: jaypslugger
Search: Search took 0.01 seconds.
-
05-21-2013, 08:20 AM
- Replies
- 21
- Views
- 445
Did you get your EPA Certification through NYCT?
Did you get your EPA Certification through NYCT?
-
05-06-2013, 02:12 PM
Thread: outdoor coil temp? why do I care?
by jaypslugger- Replies
- 11
- Views
- 402
Outdoor coil temperature is relevant because that...
Outdoor coil temperature is relevant because that is how the heat removed from the conditioned area is released to ambient air.
-
05-02-2013, 01:38 PM
Thread: how likely is injury in hvac?
by jaypslugger- Replies
- 26
- Views
- 934
I don't know your husband's age, but this is a...
I don't know your husband's age, but this is a young man's work. Their is plenty of lifting, climbing, kneeling, and bodily contortion involved. After a number of years, the little nagging injuries...
-
05-01-2013, 10:41 AM
Thread: Leak Checks and Pressure Tests
by jaypslugger- Replies
- 32
- Views
- 1,571
The ability of the unit to hold a vacuum does not...
The ability of the unit to hold a vacuum does not guarantee that the unit is tight. Consider that even under a perfect vacuum (30" hg, 0 psia) the greatest pressure differential between inside the...
-
04-30-2013, 11:03 AM
Thread: the check valve in airconditioning
by jaypslugger- Replies
- 10
- Views
- 405
Also used to prevent liquid migration to the...
Also used to prevent liquid migration to the compressor in an off cycle.
-
04-30-2013, 06:57 AM
Thread: I suppose I read too much..
by jaypslugger- Replies
- 6
- Views
- 452
Often use a heat gun but be careful; they can...
Often use a heat gun but be careful; they can remove paint.
-
04-29-2013, 11:20 AM
- Replies
- 16
- Views
- 661
It's also a real quick way to determine which of...
It's also a real quick way to determine which of the unmarked breakers feeds it:whistle:
-
03-30-2013, 09:46 AM
Thread: Discharge check valve chattering
by jaypslugger- Replies
- 4
- Views
- 314
I agree Pro. But I actually held the check and...
I agree Pro. But I actually held the check and felt it chattering.
-
03-30-2013, 09:45 AM
Thread: Discharge check valve chattering
by jaypslugger- Replies
- 4
- Views
- 314
Thanks Gas. It is a split with the compressor...
Thanks Gas. It is a split with the compressor under the car body and the evap in the interior (passenger compartment) "attic". Also, it is a spring loaded check. Condensing temp was low, but I...
-
03-29-2013, 06:15 AM
Thread: Discharge check valve chattering
by jaypslugger- Replies
- 4
- Views
- 314
Discharge check valve chattering
Greetings all. I have been asked for advice concerning an intermittent discharge check valve chatter on a subway car air conditioner. It is a Carrier Open Drive 10 ton R- 22 unit with a typical...
-
11-20-2012, 10:12 AM
Thread: The GORP is dead...
by jaypslugger- Replies
- 23
- Views
- 1,068
If the Hispanic vote is the marker, aside from...
If the Hispanic vote is the marker, aside from the immigration issue, on the surface it would appear that they would lean toward the RIGHT: generally hard working people, mostly Catholic, family...
-
10-17-2012, 06:39 AM
Thread: Do you remember your first call?
by jaypslugger- Replies
- 56
- Views
- 4,384
was a bit of an a hole...
when I ws a kid. Sent to a no cool (resi) for my first call. Find no 24v to contactor, trace it back to stat. As I'm removing the cover, H/O proudly states that it's only a year old & he did it...
-
09-15-2012, 09:25 AM
- Replies
- 33
- Views
- 2,589
Don't be so rough on yourself. We've all seen...
Don't be so rough on yourself. We've all seen this and did exactly what you did even though the little voice was telling us it might let the smoke come out of the transformer
:gah:
:cheers: -
09-13-2012, 01:41 PM
Thread: Is BHO a Muslim? You decide
by jaypslugger- Replies
- 20
- Views
- 1,150
At least he's kissing cheek at the ANTERIOR...
At least he's kissing cheek at the ANTERIOR end....
-
09-06-2012, 11:46 AM
Thread: Finally! Thanks ol' reliable!
by jaypslugger- Replies
- 4
- Views
- 464
It was marketed under a few names. Mine...
It was marketed under a few names. Mine specifically by GE. It's about 25 years old; still my "OLD RELIABLE". I have never tried it on HFCs because there was no such thing as HFC refrigerant when...
-
09-06-2012, 11:30 AM
Thread: 1500 microns
by jaypslugger- Replies
- 33
- Views
- 3,180
Two points to consider: Even if you were to...
Two points to consider:
Even if you were to attain a 500 micron vacuum, that does not mean you are absolutely leak free. The greatest pressure differential between inside your system and the... -
09-04-2012, 09:54 AM
Thread: Vacuum on package unit
by jaypslugger- Replies
- 14
- Views
- 974
What are you going to pull a vacuum on? The...
What are you going to pull a vacuum on? The system should already be charged and there is no field installed lineset.
-
09-04-2012, 07:29 AM
Thread: Democrat code words
by jaypslugger- Replies
- 3
- Views
- 566
All true. And if you have a job at all, you're...
All true. And if you have a job at all, you're "rich".
-
08-29-2012, 10:05 AM
- Replies
- 13
- Views
- 1,916
Solenoid closed most likely, but were the txv...
Solenoid closed most likely, but were the txv strainers checked? If one clogs, they both will. Since the system is recovered, open the solenoid and remove the "guts" (diaphragm, plunger etc). Put...
-
08-23-2012, 01:54 PM
Thread: New condensing unit-drier question
by jaypslugger- Replies
- 23
- Views
- 1,330
If you experienced multple failures and they have...
If you experienced multple failures and they have all been electrical, an acid condition likely exists. At the very least, an acid test should have been performed in order to prevent condemning the...
-
08-09-2012, 12:53 PM
Thread: Condensate line issues.
by jaypslugger- Replies
- 17
- Views
- 1,110
Dirty evaporator would also make it hard to open...
Dirty evaporator would also make it hard to open a cover.
-
07-30-2012, 11:57 AM
- Replies
- 11
- Views
- 1,992
Typically, the tanks are rated for 50 & 30...
Typically, the tanks are rated for 50 & 30 pounds, so they can (legally) hold 40 & 24 pounds respectively.
-
07-26-2012, 11:03 AM
Thread: a-coil wont get cold enough
by jaypslugger- Replies
- 32
- Views
- 2,208
Is the house very warm inside? Is there a panel...
Is the house very warm inside? Is there a panel open on the air handler? At 80 psig on the low side, you would have a coil temp of close to 50 degrees.
You specified that the a-coil is clean; how... -
07-19-2012, 09:31 AM
Thread: Stuck 3 phase compressor
by jaypslugger- Replies
- 20
- Views
- 2,619
You can try switching legs of the compressor...
You can try switching legs of the compressor (reversing the motor rotation). Sometimes, if you are persistent enough, this will free it. You can also try reversing the rotation and energizing the...
-
04-23-2012, 01:12 PM
Thread: EPA
by jaypslugger- Replies
- 11
- Views
- 1,123
Try www.hvac-pro.org. They have a practice...
Try www.hvac-pro.org.
They have a practice Universal Exam. I refer my students to it. It's not absolutely great, but it gives you an idea what to expect. Good luck!
Results 1 to 25 of 67