    Outdoor coil temperature is relevant because that...

    Outdoor coil temperature is relevant because that is how the heat removed from the conditioned area is released to ambient air.
  3. Replies
    26
    Views
    934

    I don't know your husband's age, but this is a...

    I don't know your husband's age, but this is a young man's work. Their is plenty of lifting, climbing, kneeling, and bodily contortion involved. After a number of years, the little nagging injuries...
  4. Replies
    32
    Views
    1,571

    The ability of the unit to hold a vacuum does not...

    The ability of the unit to hold a vacuum does not guarantee that the unit is tight. Consider that even under a perfect vacuum (30" hg, 0 psia) the greatest pressure differential between inside the...
  5. Replies
    10
    Views
    405

    Also used to prevent liquid migration to the...

    Also used to prevent liquid migration to the compressor in an off cycle.
  6. Replies
    6
    Views
    452

    Often use a heat gun but be careful; they can...

    Often use a heat gun but be careful; they can remove paint.
  7. It's also a real quick way to determine which of...

    It's also a real quick way to determine which of the unmarked breakers feeds it:whistle:
  8. Replies
    4
    Views
    314

    I agree Pro. But I actually held the check and...

    I agree Pro. But I actually held the check and felt it chattering.
  9. Replies
    4
    Views
    314

    Thanks Gas. It is a split with the compressor...

    Thanks Gas. It is a split with the compressor under the car body and the evap in the interior (passenger compartment) "attic". Also, it is a spring loaded check. Condensing temp was low, but I...
  10. Replies
    4
    Views
    314

    Discharge check valve chattering

    Greetings all. I have been asked for advice concerning an intermittent discharge check valve chatter on a subway car air conditioner. It is a Carrier Open Drive 10 ton R- 22 unit with a typical...
  11. Replies
    23
    Views
    1,068

    If the Hispanic vote is the marker, aside from...

    If the Hispanic vote is the marker, aside from the immigration issue, on the surface it would appear that they would lean toward the RIGHT: generally hard working people, mostly Catholic, family...
  12. Replies
    56
    Views
    4,384

    was a bit of an a hole...

    when I ws a kid. Sent to a no cool (resi) for my first call. Find no 24v to contactor, trace it back to stat. As I'm removing the cover, H/O proudly states that it's only a year old & he did it...
  13. Don't be so rough on yourself. We've all seen...

    Don't be so rough on yourself. We've all seen this and did exactly what you did even though the little voice was telling us it might let the smoke come out of the transformer
    :gah:
    :cheers:
  14. Replies
    20
    Views
    1,150

    At least he's kissing cheek at the ANTERIOR...

    At least he's kissing cheek at the ANTERIOR end....
  15. Replies
    4
    Views
    464

    It was marketed under a few names. Mine...

    It was marketed under a few names. Mine specifically by GE. It's about 25 years old; still my "OLD RELIABLE". I have never tried it on HFCs because there was no such thing as HFC refrigerant when...
  16. Replies
    33
    Views
    3,180

    Two points to consider: Even if you were to...

    Two points to consider:
    Even if you were to attain a 500 micron vacuum, that does not mean you are absolutely leak free. The greatest pressure differential between inside your system and the...
  17. Replies
    14
    Views
    974

    What are you going to pull a vacuum on? The...

    What are you going to pull a vacuum on? The system should already be charged and there is no field installed lineset.
  18. Replies
    3
    Views
    566

    All true. And if you have a job at all, you're...

    All true. And if you have a job at all, you're "rich".
  19. Solenoid closed most likely, but were the txv...

    Solenoid closed most likely, but were the txv strainers checked? If one clogs, they both will. Since the system is recovered, open the solenoid and remove the "guts" (diaphragm, plunger etc). Put...
  20. Replies
    23
    Views
    1,330

    If you experienced multple failures and they have...

    If you experienced multple failures and they have all been electrical, an acid condition likely exists. At the very least, an acid test should have been performed in order to prevent condemning the...
  21. Replies
    17
    Views
    1,110

    Dirty evaporator would also make it hard to open...

    Dirty evaporator would also make it hard to open a cover.
  22. Typically, the tanks are rated for 50 & 30...

    Typically, the tanks are rated for 50 & 30 pounds, so they can (legally) hold 40 & 24 pounds respectively.
  23. Replies
    32
    Views
    2,208

    Is the house very warm inside? Is there a panel...

    Is the house very warm inside? Is there a panel open on the air handler? At 80 psig on the low side, you would have a coil temp of close to 50 degrees.
    You specified that the a-coil is clean; how...
  24. Replies
    20
    Views
    2,619

    You can try switching legs of the compressor...

    You can try switching legs of the compressor (reversing the motor rotation). Sometimes, if you are persistent enough, this will free it. You can also try reversing the rotation and energizing the...
  25. Thread: EPA

    by jaypslugger
    Replies
    11
    Views
    1,123

    Try www.hvac-pro.org. They have a practice...

    Try www.hvac-pro.org.

    They have a practice Universal Exam. I refer my students to it. It's not absolutely great, but it gives you an idea what to expect. Good luck!