The 90-150 (EAB-0150) is a MT12/LT502 compressor...
The 90-150 (EAB-0150) is a MT12/LT502 compressor as I stated but the LT502 use is an alternative application for which I cannot find any btuh specs.
Based on it's CFH and the S.W.A.G theory I... -
02-25-2013, 01:09 PM
- Replies
- 13
- Views
- 355
Is this a Copeland semi-hermetic compressor? If...
Is this a Copeland semi-hermetic compressor? If so it is from the 60's with that part number 90-150. The current compressor number is an EAB?-015A-??? which is a MT12 or LT502 compressor.
-
02-22-2013, 10:43 PM
Thread: Marvin's forced retirement
by powell- Replies
- 7
- Views
- 1,179
I posted this today in the memorial section....
I posted this today in the memorial section. Marvin has passed on.
http://hvac-talk.com/vbb/showthread.php?1266331-Marvin-Greene-has-passed -
02-22-2013, 01:52 PM
Thread: Marvin Greene has passed
by powell- Replies
- 12
- Views
- 1,329
Marvin Greene has passed
Marvin Greene "Marvin" passed away last night here in Las Vegas.
At this time I do not know the cause of death.
I always enjoyed talking with him on the counter or phone. He was an excellent... -
10-19-2012, 05:42 PM
Thread: Walk In Cooler Equipment Question?
by powell- Replies
- 13
- Views
- 1,359
This is a true statement because the air is not...
This is a true statement because the air is not blown directly on unwrapped produce or flowers. But, a low velocity evap is about twice the cost versus a regular evap. This is the reason (as one...
-
10-19-2012, 12:52 PM
- Replies
- 9
- Views
- 991
There's just one little problem, the...
There's just one little problem, the ERF2-0310-CAB is a H22/M502 compressor. It's not rated for R12.:whistle:
-
08-12-2012, 03:30 PM
Thread: walk in rebuild
by powell- Replies
- 5
- Views
- 633
The model of the box doesn't help. Give us the...
The model of the box doesn't help. Give us the compressor model number and the evaporator model number.
-
08-10-2012, 11:38 PM
- Replies
- 17
- Views
- 1,317
After a few years the liquid line will leak due...
After a few years the liquid line will leak due to it rubbing together. I repaired quite a few of these in the 80's in Atlanta.
-
07-30-2012, 09:16 PM
Thread: copeland discus oil pressure
by powell- Replies
- 37
- Views
- 1,716
Ah, it uses the "Moduload" type unloader. It...
Ah, it uses the "Moduload" type unloader. It unloads based on compression ratio. It will be easier for you to understand if you read the AE bulletin from Copeland.
Here's the link
... -
07-30-2012, 09:02 PM
Thread: copeland discus oil pressure
by powell- Replies
- 37
- Views
- 1,716
Is it a single head compressor, 3D model?
Is it a single head compressor, 3D model?
-
07-27-2012, 04:28 PM
Thread: Used condensing unit.. High head pressure
by powell- Replies
- 12
- Views
- 1,926
Compressor model numbers are required for us to...
Compressor model numbers are required for us to help you.:yes:
-
07-25-2012, 08:16 PM
Thread: Walk-in-Freezer Help with compressor
by powell- Replies
- 21
- Views
- 1,901
Glad I could help. It is very similar to the...
Glad I could help.
It is very similar to the LAHA-031A-TAC -
07-10-2012, 12:28 AM
Thread: Water cooled walk in
by powell- Replies
- 11
- Views
- 808
I doubt there is no water regulating vlaves,...
I doubt there is no water regulating vlaves, unless someone screwed up. It's not about EWT, it's about head pressure.
-
07-10-2012, 12:18 AM
Thread: Water cooled walk in
by powell- Replies
- 11
- Views
- 808
[QUOTE=VTP99;13684631] K and E bodies
K and E bodies
-
07-09-2012, 12:49 AM
Thread: Condenser fan broke?
by powell- Replies
- 4
- Views
- 1,147
Hey! That aint duct tape!
Hey! That aint duct tape!
-
07-08-2012, 01:55 AM
Thread: Redneck A/C
by powell- Replies
- 3
- Views
- 626
It's a dry heat out here in the desert.
It's a dry heat out here in the desert.
-
07-08-2012, 01:46 AM
Thread: internal bypass
by powell- Replies
- 13
- Views
- 1,009
Air in the system, low side leak.:.02:
Air in the system, low side leak.:.02:
-
07-05-2012, 04:28 PM
Thread: New compressor...struggling to cool
by powell- Replies
- 15
- Views
- 1,125
I agree with you. I don't like to go less on the...
I agree with you. I don't like to go less on the BtuH unless I know the design of the system.
-
07-05-2012, 02:07 PM
Thread: New compressor...struggling to cool
by powell- Replies
- 15
- Views
- 1,125
Here's another possibility: Copeland has...
Here's another possibility:
Copeland has consolidated many of their CR models and the CR26 does cross to a CR24. The difference is about a nominal 2000 (8%) BtuH loss in capacity.
If the... -
06-30-2012, 12:58 AM
Thread: Mom passed away today...
by powell- Replies
- 62
- Views
- 3,198
My condolences to you Robin. My mother...
My condolences to you Robin.
My mother passed about 6 years ago from Alzheimer’s. I remember sitting with her near the end while we watched TV. We were watching a music channel where we played... -
06-22-2012, 06:32 PM
Thread: Sub cooling from discharge pressure?
by powell- Replies
- 10
- Views
- 1,127
He is incorrect. You want to measure the liquid...
He is incorrect. You want to measure the liquid line pressure/temp to get subcooling. The term "discharge pressure (compressor hot gas line)" is sometimes referred to as the liquid line pressure in...
-
06-21-2012, 08:59 PM
Thread: Bad Condenser coil
by powell- Replies
- 4
- Views
- 589
uni, As Mikey stated, get the model and serial...
uni,
As Mikey stated, get the model and serial number of the compressor. Measure the condenser coil, get the FPI, rows and tube size. Also state the number of fans and get any numbers at all... -
06-21-2012, 01:49 PM
Thread: Problems with walk-in med temp cooler
by powell- Replies
- 13
- Views
- 943
Miami has a good Copeland supply house, just find...
Miami has a good Copeland supply house, just find the seasoned help who learned by looking in catalogs, not the web.
Or come see me. -
06-21-2012, 01:39 PM
Thread: Problems with walk-in med temp cooler
by powell- Replies
- 13
- Views
- 943
OK, Let's assume the original compressor was...
OK,
Let's assume the original compressor was a:
LAC1-0310-CAB or LACA-031A-CAB
MT12
LT502
It does cross to a LACB-032E-CAB -
06-21-2012, 12:42 PM
Thread: Problems with walk-in med temp cooler
by powell- Replies
- 13
- Views
- 943
Craze, First, you should use paragraphs when...
Craze,
First, you should use paragraphs when writing a post this long. It's difficult to read and comprehend the way it's written.
The LAL does not cross to a LAH. It is still a current model...