  1. The 90-150 (EAB-0150) is a MT12/LT502 compressor...

    The 90-150 (EAB-0150) is a MT12/LT502 compressor as I stated but the LT502 use is an alternative application for which I cannot find any btuh specs.

    Based on it's CFH and the S.W.A.G theory I...
  2. Is this a Copeland semi-hermetic compressor? If...

    Is this a Copeland semi-hermetic compressor? If so it is from the 60's with that part number 90-150. The current compressor number is an EAB?-015A-??? which is a MT12 or LT502 compressor.
  3. Replies
    7
    Views
    1,179

    I posted this today in the memorial section....

    I posted this today in the memorial section. Marvin has passed on.

    http://hvac-talk.com/vbb/showthread.php?1266331-Marvin-Greene-has-passed
  4. Replies
    12
    Views
    1,329

    Marvin Greene has passed

    Marvin Greene "Marvin" passed away last night here in Las Vegas.

    At this time I do not know the cause of death.

    I always enjoyed talking with him on the counter or phone. He was an excellent...
  5. Replies
    13
    Views
    1,359

    This is a true statement because the air is not...

    This is a true statement because the air is not blown directly on unwrapped produce or flowers. But, a low velocity evap is about twice the cost versus a regular evap. This is the reason (as one...
  6. There's just one little problem, the...

    There's just one little problem, the ERF2-0310-CAB is a H22/M502 compressor. It's not rated for R12.:whistle:
  7. Thread: walk in rebuild

    by powell
    Replies
    5
    Views
    633

    The model of the box doesn't help. Give us the...

    The model of the box doesn't help. Give us the compressor model number and the evaporator model number.
  8. After a few years the liquid line will leak due...

    After a few years the liquid line will leak due to it rubbing together. I repaired quite a few of these in the 80's in Atlanta.
  9. Replies
    37
    Views
    1,716

    Ah, it uses the "Moduload" type unloader. It...

    Ah, it uses the "Moduload" type unloader. It unloads based on compression ratio. It will be easier for you to understand if you read the AE bulletin from Copeland.

    Here's the link
    ...
  10. Replies
    37
    Views
    1,716

    Is it a single head compressor, 3D model?

    Is it a single head compressor, 3D model?
  11. Replies
    12
    Views
    1,926

    Compressor model numbers are required for us to...

    Compressor model numbers are required for us to help you.:yes:
  12. Replies
    21
    Views
    1,901

    Glad I could help. It is very similar to the...

    Glad I could help.

    It is very similar to the LAHA-031A-TAC
  13. Replies
    11
    Views
    808

    I doubt there is no water regulating vlaves,...

    I doubt there is no water regulating vlaves, unless someone screwed up. It's not about EWT, it's about head pressure.
  14. Replies
    11
    Views
    808

    [QUOTE=VTP99;13684631] K and E bodies

    K and E bodies
  15. Replies
    4
    Views
    1,147

    Hey! That aint duct tape!

    Hey! That aint duct tape!
  16. Thread: Redneck A/C

    by powell
    Replies
    3
    Views
    626

    It's a dry heat out here in the desert.

    It's a dry heat out here in the desert.
  17. Thread: internal bypass

    by powell
    Replies
    13
    Views
    1,009

    Air in the system, low side leak.:.02:

    Air in the system, low side leak.:.02:
  18. Replies
    15
    Views
    1,125

    I agree with you. I don't like to go less on the...

    I agree with you. I don't like to go less on the BtuH unless I know the design of the system.
  19. Replies
    15
    Views
    1,125

    Here's another possibility: Copeland has...

    Here's another possibility:

    Copeland has consolidated many of their CR models and the CR26 does cross to a CR24. The difference is about a nominal 2000 (8%) BtuH loss in capacity.

    If the...
  20. Replies
    62
    Views
    3,198

    My condolences to you Robin. My mother...

    My condolences to you Robin.

    My mother passed about 6 years ago from Alzheimer’s. I remember sitting with her near the end while we watched TV. We were watching a music channel where we played...
  21. Replies
    10
    Views
    1,127

    He is incorrect. You want to measure the liquid...

    He is incorrect. You want to measure the liquid line pressure/temp to get subcooling. The term "discharge pressure (compressor hot gas line)" is sometimes referred to as the liquid line pressure in...
  22. Replies
    4
    Views
    589

    uni, As Mikey stated, get the model and serial...

    uni,

    As Mikey stated, get the model and serial number of the compressor. Measure the condenser coil, get the FPI, rows and tube size. Also state the number of fans and get any numbers at all...
  23. Replies
    13
    Views
    943

    Miami has a good Copeland supply house, just find...

    Miami has a good Copeland supply house, just find the seasoned help who learned by looking in catalogs, not the web.

    Or come see me.
  24. Replies
    13
    Views
    943

    OK, Let's assume the original compressor was...

    OK,

    Let's assume the original compressor was a:

    LAC1-0310-CAB or LACA-031A-CAB
    MT12
    LT502

    It does cross to a LACB-032E-CAB
  25. Replies
    13
    Views
    943

    Craze, First, you should use paragraphs when...

    Craze,

    First, you should use paragraphs when writing a post this long. It's difficult to read and comprehend the way it's written.

    The LAL does not cross to a LAH. It is still a current model...