  1. Welp this system doesn't work. 1st EIM and IAQ...

    Welp this system doesn't work. 1st EIM and IAQ with the HZ322 tech spend over an hour trying to get to work...no joy but he took my money for the service fee. 2nd tech spend 3 hours between him,...
  2. The thing that got me and him was that is works...

    The thing that got me and him was that is works in test mode, AC, Fan, and Heat all come on
  3. OK the tech spend 3 hours here today and even...

    OK the tech spend 3 hours here today and even replaced the IAQ and EIM and it still doesn't work. It works for testing but will never turn on the AC Condenser in normal operation. I think Honeywell...
  4. The R he wired to the 24VAC dedicated. He ran...

    The R he wired to the 24VAC dedicated.

    He ran the test from the IAQ. He said the zone panel didn't need to run a test because the 2nd Zone stat works.
  5. One Thermostat is wireless so it has a wireless...

    One Thermostat is wireless so it has a wireless unit.
  6. Actually here I took a better picture of the EIM...

    Actually here I took a better picture of the EIM 412811

    Here is the Zone Panel 412821
  7. 412801 Sorry it's sideways. When I removed...

    412801

    Sorry it's sideways. When I removed the cover wires kind of popped everywhere, lol.
  8. Ok So another tech got everything wired and...

    Ok So another tech got everything wired and working, at least for the Test which he showed me. However now it never turns the AC on by itself. I called him back and it worked for the test again and...
  9. well please tell me a tech in the kcmo area...

    well please tell me a tech in the kcmo area because this one played with some wires then took it all down and said it can't be done. The tech was from a very large company that is pretty much all...
  10. Looks like I'm calling a new tech. The Equipment...

    Looks like I'm calling a new tech. The Equipment interface module is there.
  11. VisionPro IAQ EIM to HZ322...can it be done?

    So my tech tried hooking up my VisionPro IAQ thermostat to my HZ322 zone panel and then said it can't be done. So I'm sitting here with a $ thermostat that I can't use. Is it true this can't be...
  12. Replies
    0
    Views
    247

    No condensation from drain line?

    The humidity in the area has been almost non-existent but still I would think my HVAC should have condensation coming from the drain line, am I correct? The house feels great and is cooling,...
  13. Replies
    7
    Views
    634

    Thank you. I blocked it off and the other...

    Thank you. I blocked it off and the other returns aren't loud. The water heater is in a different room so no worries there.
  14. Replies
    7
    Views
    634

    anything? I'm thinking just that the small 8x10...

    anything? I'm thinking just that the small 8x10 return is closer to the return stack so it is the shortest distance (least resistance) and therefore is the first return used. Meaning the longer...
  15. Replies
    7
    Views
    634

    2.5t A/C and 70k VS 2 stage furnace.

    2.5t A/C and 70k VS 2 stage furnace.
  16. Replies
    7
    Views
    634

    ok so no replies. Does anyone need more...

    ok so no replies. Does anyone need more information or is this just one of those maybe maybe not type things?
  17. Replies
    7
    Views
    634

    Return question

    So I have a split level with a finished basement. There is a large 8x24 return in the hallway of the upstairs and a 8x24 return in the lower level. Then in the basement there is a 10x10 return in...
  18. Replies
    2
    Views
    437

    thank you. I will tell him that he needs to make...

    thank you. I will tell him that he needs to make it do that because it can.
  19. Replies
    2
    Views
    437

    Honeywell IAQ

    So I just paid for a IAQ thermostat and the contractor said it won't control the speed of my Goodman VS 2 stage furnace because the AC is only a single stage system. Is that true? I have read on...
  20. Replies
    14
    Views
    1,290

    Ok I'm getting the guy who installed the furnace...

    Ok I'm getting the guy who installed the furnace back out, but I'm going to ask for a comfort specialist to come as well. I have some questions.
    What do I say if he says a 2 stage isn't needed?...
  21. Replies
    14
    Views
    1,290

    OK so the tech recommended upsizing from the...

    OK so the tech recommended upsizing from the 2.5ton single stage AC to a 3 ton single stage Lennox 13ACX036 and upgrading to a VisionPro thermostat. Price was about the cost of a high end fridge. ...
  22. Replies
    14
    Views
    1,290

    I am having the HVAC tech bleed some more airflow...

    I am having the HVAC tech bleed some more airflow off. Any last minute questions I should ask? He'll be here in an hour.
  23. Replies
    14
    Views
    1,290

    OK I have an American Standard "NATE" certified...

    OK I have an American Standard "NATE" certified contractor coming out tomorrow to discuss AC replacement options. Mind you that I have a goodman furnace. What should I ask him in particular? TXV?...
  24. Replies
    14
    Views
    1,290

    George2 - I already have a gas new furnace so I...

    George2 - I already have a gas new furnace so I would have to replace it with a dual heat unit to get a heat pump.

    Dan - I'm going to answer backwards. Yes I am very frugal and my energy...
  25. Replies
    14
    Views
    1,290

    Basement cooling, zoning

    First I want to thank everyone on here for all the advice you have given me. Last fall I upgraded from my old 80% 100k furnace to a 70k Goodman 95% VS 2 stage unit and it is amazing. *some problems...
  26. Replies
    15
    Views
    2,481

    I didn't know that could be done...what has to be...

    I didn't know that could be done...what has to be done for that to happen?
  27. Replies
    15
    Views
    2,481

    NCHeat - HVAC guy said I can't use a barometric...

    NCHeat - HVAC guy said I can't use a barometric bypass because it will confuse the VS blower speed? Something about the barometric bypass opens and closes with cfm and the VS tries to maintain an...
  28. Replies
    15
    Views
    2,481

    Oh ok thanks. Right now there is a 8x8 return. ...

    Oh ok thanks. Right now there is a 8x8 return. The HVAC tech said it was added years ago, probably, when the AC was installed. What he talked about was adding a 10x8 damper that would open when...
  29. Replies
    15
    Views
    2,481

    No load calculation done. He did one for the...

    No load calculation done. He did one for the upstairs when the furnace was installed which is why I went down from 90k to 70k but didn't count the basement. I really don't know what 1000 fpm means...
  30. Replies
    15
    Views
    2,481

    Ok now I'm confused. SBKold - How does Round...

    Ok now I'm confused.

    SBKold - How does Round flow the best? It is cheaper too, but what will it do vs rectangle?

    RyanHughes - a 10" and 8" is not enough? What should I ask for? What is...
  31. Replies
    31
    Views
    4,146

    320921320931 Ok here is a before and after...

    320921320931

    Ok here is a before and after shot. Along with the new furnace I got a larger better intake boot, new exhaust ducting, and gas line. The A-coil had to have a transition made because...
  32. Replies
    15
    Views
    2,481

    Great. Thank you!

    Great. Thank you!
  33. Replies
    10
    Views
    2,814

    This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  34. Replies
    15
    Views
    2,481

    Round or Rectangle ducting?

    Ok so I have a brand new Goodman gmvc95 furnace with Honeywell HZ311 using two zones. I am getting ready to have my third zone installed (basement 550 sqft). So had the HVAC guy out and with the...
  35. Replies
    31
    Views
    4,146

    INSTALLED

    Hey everyone I got the GMVC95070 installed. I moved down from a 90k 80% to 70k 95%. Also I gained two stage and VS. I'll post pictures tonight for you techs to grade the install. I have some...
  36. Replies
    14
    Views
    1,621

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary or ask questions of the OP here. Please apply to the AOPC today, thank you.

    You...
  37. Replies
    31
    Views
    4,146

    Beenthere, thank you I just saw that on his bid,...

    Beenthere, thank you I just saw that on his bid, he said VS at the house but the bid is ECM.

    Ok all so the York equipment and install is just under double the Amana VS 2 stage, which should I...
  38. Replies
    14
    Views
    1,621

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary or ask questions of the OP here. Please apply to the AOPC today, thank you.

    You...
  39. Replies
    14
    Views
    1,621

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary or ask questions of the OP here. Please apply to the AOPC today, thank you.

    You...
  40. Replies
    31
    Views
    4,146

    Ok So the HVAC is going to quote me a 1 stage VS...

    Ok So the HVAC is going to quote me a 1 stage VS 95.5% furnace with humdifier, and 2stage VS 96% furnace. I really want the 2 stage so we'll see price. However because I don't plan to stay here...
  41. Replies
    31
    Views
    4,146

    So I am going with the 2 stage because I can't...

    So I am going with the 2 stage because I can't take advantage of the Mod Furnace...thank you. HVAC tech will be here in 20 minutes. Any last minute advice on questions to ask?
  42. Replies
    31
    Views
    4,146

    Yes the HZ322, what I have, will keep high off...

    Yes the HZ322, what I have, will keep high off until more than one zone calls.
  43. Replies
    31
    Views
    4,146

    jtrammel - ok as honestly and neutral bias as you...

    jtrammel - ok as honestly and neutral bias as you can be, outside price why would anyone take the affinty line of the LX? The TM9V looks awesome, VS 2 stage and 96%!
  44. Replies
    31
    Views
    4,146

    Ok well I will not settle for under 95%, 2 stage,...

    Ok well I will not settle for under 95%, 2 stage, and VS. Does the LX line offer that? The Honeywell panel is the HZ322, with the wireless panel and a 3 stage heat 2 stage cool thermostat for the...
  45. Replies
    31
    Views
    4,146

    York Furnace and Honeywell Zoning

    So I had planned on going with a Goodman 95% 2 stage VS furnace installed by the same tech who did my zoning, however for whatever reason since the zoning install that hvac tech is no longer...
  46. Replies
    14
    Views
    1,783

    TedKidd - once the new furnace is installed I...

    TedKidd - once the new furnace is installed I will take you up on that offer!
  47. Replies
    14
    Views
    1,783

    I've already had an energy audit done, which let...

    I've already had an energy audit done, which let to increased attic insulation, increase attic ventilation, increased wall insulation, adding floor insulation above garage, air sealing, double pane...
  48. Replies
    14
    Views
    1,783

    There is no problem but I want a "energy...

    There is no problem but I want a "energy efficient" system and if new duct was required then so be it. However based on the advice given I will not be doing new duct, especially not in the...
  49. Replies
    14
    Views
    1,783

    Thanks, guess I'll pass on the in attic duct. ...

    Thanks, guess I'll pass on the in attic duct. All the ductwork is sheet metal, so a 10x20 grille has a 10x20 metal duct behind it.

    I'll look into "transfer grilles"
  50. Replies
    14
    Views
    1,783

    Return Ductwork in Attic...or worth it?

    So after my HVAC tech did my zoning system install, which I love, we started speaking about my soon to be new variable speed 2stage goodman/amana furnace and possible addition of return ducts. Right...
Results 1 to 50 of 79