  1. Replies
    12
    Views
    317

    Box next to the furnace is a 16x25x5 filter. ...

    Box next to the furnace is a 16x25x5 filter. Little thumbscrew at the top of the box, whole front comes off as the door. Custom made, insulated…. Put on on every system we do.
  2. Replies
    12
    Views
    317

    I did run new hose to the pump.

    I did run new hose to the pump.
  3. Replies
    12
    Views
    317

    I changed it less than a year ago. Sure I reused...

    I changed it less than a year ago. Sure I reused it.
  4. Replies
    12
    Views
    317

    I got the evaporator out of the return.

    Just another changeout. Old system had the coil in the filter side of the old furnace before the york was put in.

    https://farm4.staticflickr.com/3801/13911586254_0b40b61584_b.jpg

    ...
  5. Scratch and dent at my supply house means it got...

    Scratch and dent at my supply house means it got dropped and then ran over.
    Install looks nice.
  6. Replies
    45
    Views
    2,894

    Reason enough to go with Triangle tube boilers. ...

    Reason enough to go with Triangle tube boilers. At least when you call them about servicing and warranty they don't tell you you're S.O.L.

    Navien is a horrible company to deal with.
  7. Thread: W/W geo

    by jimmyed
    Replies
    13
    Views
    1,226

    Nice metal work!

    Nice metal work!
  8. Replies
    9
    Views
    647

    I find ones like used above sometimes don't have...

    I find ones like used above sometimes don't have enough water in them. Seen them on bigger systems pull water up enough to make the trap "dry" and then not drain right. I like EZtraps but still...
  9. Replies
    9
    Views
    647

    Too much flex. Don't like P traps. Nice install. ...

    Too much flex. Don't like P traps. Nice install. More time could have been spent on it, say the same about all of mine. I don't do many geo's, they require a lot of time. I hate geo's, try to never...
  10. Replies
    6
    Views
    1,001

    I got a secret. Cut out your metal. Find a piece...

    I got a secret. Cut out your metal. Find a piece of cardboard or carpet. Lay metal face down on carpet or cardboard, lay a straight edge from corner to corner. Take straight screw driver and run...
  11. Replies
    47
    Views
    3,833

    Nice to see someone takes pride in there work…...

    Nice to see someone takes pride in there work… Things I would have done different, Not used honeywell zoning. Too many failures with their products. Not a fan of goodman, even their new stuff. ...
  12. Replies
    24
    Views
    3,080

    Needs to get above freezing and I need to get...

    Needs to get above freezing and I need to get home before dark.
  13. Replies
    3
    Views
    892

    Another Infinity...

    Took out a Heil fan coil. Replaced everything but ductwork and line set. Increased return drop from 20x8 to 20x12. 3 ton system. 20x20x5 media filter. All ductwork made prior to showing up to do...
  14. Replies
    12
    Views
    1,392

    Meh I didn't think his work was that...

    Meh I didn't think his work was that spectacular...
  15. Replies
    12
    Views
    1,392

    Theres a 4 or 5" thick filter in that short way...

    Theres a 4 or 5" thick filter in that short way 90?
  16. Replies
    12
    Views
    1,392

    Media filters! :gah: Sell one with every job. ...

    Media filters! :gah: Sell one with every job. Don't even give them the option. No dirty coils, seldom a clogged drain....
  17. Replies
    4
    Views
    1,066

    Lol Said nothing about return upstairs… Thats an...

    Lol Said nothing about return upstairs… Thats an evolution furnace, probably outdoor, not even hooked to an evolution stat… What hacks and what a waste of nice equipment.
  18. Replies
    10
    Views
    1,701

    Why not hard pipe gas?

    Why not hard pipe gas?
  19. Replies
    20
    Views
    3,819

    Who makes the compressor?

    Who makes the compressor?
  20. Put your filter drier inside!!!!!! Especially...

    Put your filter drier inside!!!!!! Especially since you're in the "rain belt"
  21. Replies
    34
    Views
    4,604

    Base is 24ga and not cross broke. Plenty strong...

    Base is 24ga and not cross broke. Plenty strong to hold the furnace and coil up.
  22. Replies
    12
    Views
    1,130

    5" thick merv 11 filter. Sheetmetal shop makes...

    5" thick merv 11 filter. Sheetmetal shop makes the filter boxes. Insulated on all 4 sides. Many different configurations. We put them on every system. Yeah it is just a plastic thing, a "shop...
  23. Replies
    12
    Views
    1,130

    Comes with the breakered heat packs.

    Comes with the breakered heat packs.
  24. Replies
    12
    Views
    1,130

    Yeah, it has an eztrap on it down near the floor.

    Yeah, it has an eztrap on it down near the floor.
  25. Replies
    12
    Views
    1,130

    Could but his intentions were to move the laundry...

    Could but his intentions were to move the laundry to the garage "eventually"… Stuck a trash can in there for now.