Search:

Type: Posts; User: reliablehvac

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    49
    Views
    5,706

    Yep I use the Precendent ....choice of...

    Yep I use the Precendent ....choice of electromechanical or microprocessor
  2. Replies
    33
    Views
    3,441

    yep just dealing with the basic summer...

    yep just dealing with the basic summer overcharge....;)
  3. Replies
    49
    Views
    5,706

    ok that's good.... talking installation ease and...

    ok that's good.... talking installation ease and pricing as main factors
  4. Replies
    33
    Views
    3,441

    essentially the suction line will be about the...

    essentially the suction line will be about the same temp. give or take 5degreesF (that's why I say no difference) r22 at 70psi sat temp is 40F with 10degree superheat 50F r22 overcharged to 85psi...
  5. Replies
    3
    Views
    412

    :mad: I want access to pro forum ......{while...

    :mad: I want access to pro forum ......{while banging on the door} :)
  6. Replies
    204
    Views
    26,519

    6 in 1 or 10 in 1 whichever I grab first..... the...

    6 in 1 or 10 in 1 whichever I grab first..... the must have of all jobs and it definitely lightens the old tool load. :)
  7. Replies
    33
    Views
    3,441

    that's the superheat maybe ur reading it from...

    that's the superheat maybe ur reading it from wrong direction... u add refrig to lower superheat and remove refrig. to raise Superheat
  8. Replies
    49
    Views
    5,706

    no that's exactly the type of info I wanna...

    no that's exactly the type of info I wanna hear.... in fact I'll call our Lennox supplier tomorrow and see if he can sell me on it ..:) at least get an estimate ..at this point price may be the...
  9. Replies
    10
    Views
    429

    didnt know your questions was saying it had to be...

    didnt know your questions was saying it had to be superheated before entering....generally if u ask a simple question asking what key component is responsible for superheating the refrigerant (how I...
  10. Replies
    10
    Views
    429

    lol evaporator maybe :p you really cant be...

    lol evaporator maybe :p you really cant be confused on that
  11. Replies
    49
    Views
    5,706

    I'm not to high on Lennox residential what's make...

    I'm not to high on Lennox residential what's make the Lennox L better as a RTU..(oh these have the normal accesories smoke detector, economizer, roof curbs)
  12. Replies
    33
    Views
    3,441

    I didnt say suction line would be cooler....said...

    I didnt say suction line would be cooler....said pressures would be higher.. as far as the sub cooling ...with the system in a flooded state you would have most of the vapor condensing into a...
  13. Replies
    17
    Views
    938

    I've worked on the solar heating system(hot...

    I've worked on the solar heating system(hot water, heating) but never seen a solar energy system .... would want to hear more if anyone has info on it
  14. Replies
    10
    Views
    751

    Dont know about here in Ga but I did a job in NC...

    Dont know about here in Ga but I did a job in NC where I was told I was responsible as the licensed contractor to make sure everything was to code.
  15. Replies
    10
    Views
    751

    Bad Architect - what should I do?

    I've caught a couple of different errors on the blueprints that the architect had to replace. I've talked to him a couple of times and I'm not confident in his knowledge. Should I go back over...
  16. Replies
    49
    Views
    5,706

    Trane best RTU or are there better?

    Hi I'm in the process of an installation with 3 6-tons 150kbtu gas pack roof top units... I normally use Trane. Is this the best or are there better RTU's price or quality just wanna know?
  17. how long?

    How long does it generally takes ....between applying for pro mem. and getting it.
  18. Replies
    33
    Views
    3,441

    subcooling would be higher but that's on the...

    subcooling would be higher but that's on the liquid line and the op was asking if the suction line would be cooler .... one thing to keep in mind with an overcharge the pressures would be higher...
  19. assuming your fan motor is multi speed - cooling...

    assuming your fan motor is multi speed - cooling runs on higher speed, heating at lower speed (generally) with t-stat set to auto
  20. Replies
    4
    Views
    494

    Sounds like to me he was asking about outdoor air...

    Sounds like to me he was asking about outdoor air requirements/effects on unit.
    versus air flow restrictions or fresh air for combustion (because if he meant these I think he may have mentioned...
  21. Replies
    27
    Views
    2,005

    The answer is going to be call an HVAC...

    The answer is going to be call an HVAC professional to check out the situation and to do load calculations to size duct work properly
  22. Replies
    3
    Views
    345

    yep as long as it's set up to do that it should...

    yep as long as it's set up to do that it should work otherwise there is a problem with the ac system in general not the tonnage/design
  23. Replies
    20
    Views
    1,444

    That definitely seems high.... I'm currently...

    That definitely seems high.... I'm currently doing a job with an occupancy of 138 people blueprints has 3 4ton units with OA req. 2760cfm (table 403.3). This is a kids play business 7,000sq/ft....
  24. I'm not talking about a specific bid. No one...

    I'm not talking about a specific bid. No one would throw out a rule of thumb bid. What I'm looking for are some rules of thumbs for eyeballing jobs when you're looking through hundreds of them. I...
  25. Replies
    4
    Views
    1,021

    no just mixed up blueprints running gas lines to...

    no just mixed up blueprints running gas lines to packaged heat pumps
Results 1 to 25 of 52
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event