Search:

Type: Posts; User: bdx

Search: Search took 0.00 seconds.

  1. Thread: Tekmar programming

    by bdx
    Replies
    0
    Views
    541

    Tekmar programming

    I recently purchased a home with a tekmar D512 thermostat on a viessmann hyrdonic system.

    I have no idea how to program it. If anyone has any advise I would appreciate it.

    Thx BDX
  2. Thread: Fresh air ducting

    by bdx
    Replies
    4
    Views
    590

    I have a 2 zone AC system in my house (no...

    I have a 2 zone AC system in my house (no heating). There are many cool evenings I would like to be able to take air from outside and distribute in my house. I know there are some commercial...
  3. Replies
    3
    Views
    825

    What should I be doing to assure my AC system is...

    What should I be doing to assure my AC system is 'winternzed'? I see some people cover the compressors or disconnect the power to the system but not sure this is value added. I have a totally...
  4. Replies
    10
    Views
    1,265

    Thx again, I will check it out.BDX

    Thx again, I will check it out.BDX
  5. Replies
    10
    Views
    1,265

    Thanks for the reply. Unfortunately, I was not...

    Thanks for the reply.

    Unfortunately, I was not home when this was installed, I will call the person tomorrow, but how can I check to see if I have a humistat and if not installed, where would it...
  6. Replies
    10
    Views
    1,265

    I recently upgraded my air handler to a variable...

    I recently upgraded my air handler to a variable speed York (4ton). It was installed this week and the tech did an outstanding job installing and hanging the unit.. a work of art and the unit runs...
  7. Replies
    8
    Views
    1,700

    I had to deal with a similar issue with new...

    I had to deal with a similar issue with new construction. The interesting issue was the electricial and plummer that were sub contracted were first rate. The ac guy was third rate. After getting...
  8. Replies
    9
    Views
    1,004

    thanks, found it and it was plugged solid with...

    thanks, found it and it was plugged solid with dust and dirt...
  9. Replies
    9
    Views
    1,004

    ok thx... if you don't mind, please tell me what...

    ok thx... if you don't mind, please tell me what the filer is/does.
  10. Replies
    9
    Views
    1,004

    I was wondering why my house was not getting cool...

    I was wondering why my house was not getting cool after the ac was running for several hours. Looking at the compressor and at first glance it looked like the refrigerant piping was pvc, however...
  11. Replies
    4
    Views
    617

    thx for the reply, why would dampers cause a...

    thx for the reply, why would dampers cause a variable speed unit motor to burn out?
    thx
  12. Replies
    4
    Views
    617

    recently purchased home and found the lower level...

    recently purchased home and found the lower level air handler was undersize as installed. The contractor that came and evaluated the system also identified need to put dampers in each take off for...
  13. Replies
    17
    Views
    1,446

    working with a top notch contractor is worth a...

    working with a top notch contractor is worth a premium I am happy to pay for top notch professionals that take pride in every single thing they do.

    My only relief on price I ask for is a discount...
  14. Replies
    6
    Views
    1,218

    Can someone tell me the benfits of one over the...

    Can someone tell me the benfits of one over the other. Unit I am needing to replace is AC only, not for heating. Thx
  15. Replies
    2
    Views
    889

    Moved into a new home and following some cooling...

    Moved into a new home and following some cooling issues on the first floor, a HVAC evaluation uncovered an undersized air handler that services the first floor (two zone system one for second. ...
  16. Replies
    56
    Views
    6,908

    I took a hammer to the last digital t-stat I had...

    I took a hammer to the last digital t-stat I had and went back to honeywell analog and have not had a problem since
  17. Thread: Burnham Furnaces

    by bdx
    Replies
    3
    Views
    1,395

    Burnham

    Burnham has a pretty good website that may be able to answer your question. http://www.burnham.com/
  18. Replies
    7
    Views
    789

    thanks tinknocker ,,,, are dampers someting to...

    thanks tinknocker ,,,, are dampers someting to install in the attic correct? I have flexible runs up there now. Any specs or product you like?

    thx for the response.BDX
  19. Thread: Whats my worth

    by bdx
    Replies
    34
    Views
    2,665

    There are several dimensions to what you're...

    There are several dimensions to what you're worth. There is what your boss charges your time out for and what you make on an hourly basis. In NYC this may be 10 times where you are now based on...
  20. Replies
    7
    Views
    789

    yes, two separate units, with one zone upstairs...

    yes, two separate units, with one zone upstairs and one down. The system is only one season old but with out any data...the downstairs unit seems undersized.

    thanks for the response doc
  21. Replies
    7
    Views
    789

    Hi, I recently purchased a new home with two...

    Hi,

    I recently purchased a new home with two zone ac one covers the upper levels and one covers the lower level. I have been having an issue balancing the lower level unit airflow. One room is...
Results 1 to 21 of 21