    I've seen plenty of neg superheat on low temp...

    I've seen plenty of neg superheat on low temp racks during flood back situations!
  3. I would check LLSV. Start compressor (only the...

    I would check LLSV. Start compressor (only the troubled one) let it run for awhile. Then raise set point and watch it. See if it pumps down correctly.
  4. Replies
    12
    Views
    3,328

    Where are you located? Looks like maybe jersey?...

    Where are you located? Looks like maybe jersey? Too little unless it's managing a few techs then you could moonlight to make up the difference:grin2:
  5. Replies
    12
    Views
    3,328

    Where are you located? Looks like maybe jersey?...

    Where are you located? Looks like maybe jersey? Too little unless it's managing a few techs then you could moonlight to make up the difference
  6. Replies
    23
    Views
    2,008

    sporland rcw-42....look it up

    sporland rcw-42....look it up
  7. Replies
    23
    Views
    2,008

    Ok....If I have a contaminated system IE(.Burn...

    Ok....If I have a contaminated system IE(.Burn out), I use the appropriate suction line filter drier and replace in a few days. They make them specifically for high moisture and acid exposed systems....
  8. Replies
    23
    Views
    2,065

    Still a bit low on charge I would say. Subcooling?

    Still a bit low on charge I would say. Subcooling?
  9. Replies
    23
    Views
    2,008

    I hate to answer a question with a question but...

    I hate to answer a question with a question but why do they make both suction AND liquid line filter driers?
  10. Replies
    23
    Views
    2,008

    NO!!!

    NO!!!
  11. Replies
    3
    Views
    927

    All the ones Ive worked on have been ccw to lower...

    All the ones Ive worked on have been ccw to lower psi. That said, it's not a set in stone rule just my experience.
  12. Replies
    14
    Views
    1,759

    3/8" makes a difference for larger systems. A 2...

    3/8" makes a difference for larger systems. A 2 or 3lb system 1/4" is fine. I work mostly on 50-1000lb systems so 3/8" is in my hands often. Core removal is also a must on recovery of large...
  13. Replies
    35
    Views
    2,484

    Ok I give up. Just do it anyway you would like....

    Ok I give up. Just do it anyway you would like. Not mad but don't know how else to explain pumping down a system into the RECEIVER not CONDENSER.
  14. Replies
    35
    Views
    2,484

    If you close the outlet of the receiver it all...

    If you close the outlet of the receiver it all has to at some point go through the condenser.

    Think about the cycle it'll work perfectly. I can pump a 400# rack down 99% in just a few min then...
  15. Replies
    35
    Views
    2,484

    As I said, I meant no offense. Just don't wanna...

    As I said, I meant no offense. Just don't wanna step by step a consumer.

    I still stand by my method of pumping it down to the receiver. Simply close the outlet to the receiver and let it pump...
  16. Replies
    35
    Views
    2,484

    I see no reason why the refrigerant can't be...

    I see no reason why the refrigerant can't be condensed. The OP simply asked the quickest way to pump out a condenser.

    Now if he asked the quickest way to pump out a condenser without fans.....
  17. Replies
    35
    Views
    2,484

    ^^^^ No offense but you don't have pro status...

    ^^^^ No offense but you don't have pro status thus I'm not walking you through step by step.

    I can assure you though that IF you get pro status come back and your questions can be answered.
  18. Replies
    35
    Views
    2,484

    use compressor to pump into receiver. No faster...

    use compressor to pump into receiver. No faster way imho.
  19. Replies
    39
    Views
    3,469

    Most likely infiltration

    Most likely infiltration
  20. Replies
    26
    Views
    3,005

    Totally normal..... on a -20 rack:whistle: ...

    Totally normal..... on a -20 rack:whistle:

    http://i1094.photobucket.com/albums/i453/2002vinny/frostly.jpg
  21. ^^^^ agree^^^^^ I replace mine with o rings from...

    ^^^^ agree^^^^^ I replace mine with o rings from lowes or HD and works fine.

    On another note, I think using analog is good to start off. New techs need to think about whats going on with the...
  22. Replies
    30
    Views
    2,925

    Installed a few and no complaints so far.

    Installed a few and no complaints so far.
  23. Replies
    30
    Views
    2,925

    paragon has a new digital timer that replaces all...

    paragon has a new digital timer that replaces all the 8000 series so no need to carry multiple timers for paragon replacement. Also had a memory program that has 10 hrs of life after power outages....
  24. Replies
    24
    Views
    4,273

    80k????? Thats a bad bad year:pileon:

    80k????? Thats a bad bad year:pileon:
  25. Just a guess.... 17-20/hr

    Just a guess.... 17-20/hr
Results 1 to 25 of 361
Page 1 of 15 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event