04-04-2012, 09:11 PM
Thread: compressor chatter
by bertqc- Replies
- 12
- Views
- 788
What if the tech before you remove the TXV bulb...
What if the tech before you remove the TXV bulb because Suct. pressure was too low, just to test it...after some test, 4h30pm friday, he decided to unplug c2 coil. Never went back there. Restriction...
-
04-04-2012, 09:01 PM
Thread: Lennox L Series Software
by bertqc- Replies
- 3
- Views
- 613
Thanks, i will call Lennox tomorrow. Do you think...
Thanks, i will call Lennox tomorrow. Do you think USOPTL4 from B&B Electonics will do the job for rs-485 to USB? I ask because i already have this converter, i use it when connectiong to a specific...
-
04-04-2012, 08:11 PM
Thread: compressor chatter
by bertqc- Replies
- 12
- Views
- 788
What you mean by "blockage"? An unfasten bulb...
What you mean by "blockage"? An unfasten bulb will not block refrigerant. A loss of charge in bulb will. You're not very curious. Usually when you change a TXV, you have to test it. I suspect TXV was...
-
04-04-2012, 04:27 PM
Thread: Lennox L Series Software
by bertqc- Replies
- 3
- Views
- 613
Lennox L Series Software
I 'm trying to connect my laptop to a lca150 rtu with IMC card. Rtu is not part of a network. I have the L Connection Software found on Lennox website. What else do i need to acheive this at lowest...
-
10-13-2009, 05:32 PM
Thread: Boiling water in service valve
by bertqc- Replies
- 46
- Views
- 2,804
Anyway those valves NEVER leak! :eek2:
Anyway those valves NEVER leak! :eek2:
-
05-02-2008, 12:26 AM
Thread: Demo mini-AHU for Quebec Skills Games
by bertqc- Replies
- 16
- Views
- 2,682
For those who are not working on ahu i'll explain...
For those who are not working on ahu i'll explain how this system is working.
First : ventilation.
You got 2 blowers supply blower and return blower. the supply blower is located down right and... -
04-19-2008, 06:45 PM
Thread: Demo mini-AHU for Quebec Skills Games
by bertqc- Replies
- 16
- Views
- 2,682
Demo mini-AHU for Quebec Skills Games
This is a project we've been working on for several weeks in school ( HVAC/R school ). It has been done by students from a to z. We have done 4 of theses working demo AHU. They will be troubleshooted...
-
01-14-2008, 11:28 PM
Thread: Heat Pump Explosion Forensics!
by bertqc- Replies
- 28
- Views
- 1,833
Kink in liquid line would cause a pump down in...
Kink in liquid line would cause a pump down in cooling.
If set in heating..i agree it could cause high pressure issue since id coil doesn't hold the charge...usually when we say a relief valve is in... -
12-29-2007, 07:27 PM
- Replies
- 21
- Views
- 1,176
Condensate pump will only stop HP..Aux heat will...
Condensate pump will only stop HP..Aux heat will still work..
-
12-28-2007, 03:05 PM
Thread: duct noise driving me crazy
by bertqc- Replies
- 15
- Views
- 1,456
A recording of the sound could help :) just a...
A recording of the sound could help :)
just a joke..
Could be as simple as a noisy relay.. -
12-28-2007, 03:00 PM
- Replies
- 21
- Views
- 1,176
Biggest problems occurs when the clear tube is...
Biggest problems occurs when the clear tube is pinch..other than that they work well.
-
12-28-2007, 02:58 PM
Thread: Condenser Enclosure Heat Removal
by bertqc- Replies
- 17
- Views
- 1,246
Is there a possibility to use a kind of power...
Is there a possibility to use a kind of power exhaust fan to evacuate hot air and a damper to let fresh air enter...
-
12-28-2007, 02:52 PM
Thread: HP lineset insulation
by bertqc- Replies
- 2
- Views
- 452
Don't insulate the liquid line...Should not be...
Don't insulate the liquid line...Should not be critical in heating mode but in cooling you want to be sure to have a good subcooling whick will help eliminate flash-gaz which will lead to a better...
-
12-20-2007, 11:46 PM
Thread: Heat pump not pumping!
by bertqc- Replies
- 7
- Views
- 2,039
I don't install Goodman but i though the...
I don't install Goodman but i though the reversing valve was energized in cooling. It's kind of strange you had AC with 1cool/1heat tstat since they're not supposed to energize O. Maybe White Rogers...
-
12-19-2007, 01:16 AM
Thread: Heat pump not pumping!
by bertqc- Replies
- 7
- Views
- 2,039
Probably not a big problem...to solve Find a...
Probably not a big problem...to solve
Find a good tech with a good multimeter and you're in business. -
12-19-2007, 01:11 AM
- Replies
- 10
- Views
- 5,542
[QUOTE=kwkheat;1703093] The guy who installed the...
[QUOTE=kwkheat;1703093] The guy who installed the thermostat just said to switch over when the temperature stayed below freezing for several days.
I'd say it depends where you live and electricity... -
12-19-2007, 12:57 AM
Thread: HP Defrost operation w/Dual Fuel system
by bertqc- Replies
- 19
- Views
- 1,406
Huh, defrost wiil occur at temp over 35F since...
Huh, defrost wiil occur at temp over 35F since your OD coil is below 32F..and since RH is higher at 35F than 15F as an exemple defrost will happen more often.
To answer the main question, look... -
12-17-2007, 11:23 PM
Thread: Heat Pump Evap coil location
by bertqc- Replies
- 24
- Views
- 1,270
Always better to put the coil in the return Why?...
Always better to put the coil in the return
Why?
- Heat stages will work together. They can't if coil is in the supply because head pressure rise.
- Coil isn't exposed to Aux heat
- No need to... -
12-11-2007, 11:56 PM
Thread: armstrong heat pump problem
by bertqc- Replies
- 8
- Views
- 2,170
I'm also surprised that a service tech doesn't...
I'm also surprised that a service tech doesn't know which tx valve to check. NO DIY.
-
11-09-2007, 12:59 AM
Thread: discharge line freezing
by bertqc- Replies
- 41
- Views
- 3,360
IMPOSSIBLE to freeze on the discharge line. The...
IMPOSSIBLE to freeze on the discharge line. The only thing that could make it freeze is a big restriction...and if you have a restriction anywhere before the condenser your head pressure will go...
-
11-09-2007, 12:47 AM
Thread: Adjusting charge on heat pump
by bertqc- Replies
- 2
- Views
- 587
Superheat can tell ;)
Superheat can tell ;)
-
11-09-2007, 12:45 AM
- Replies
- 27
- Views
- 1,935
I agree it sounds like a defrost. We can hear the...
I agree it sounds like a defrost. We can hear the reversing valve through the piping in the furnace and then your docking help the sound transmission. W1 probably set to work on low speed that's why...
-
09-26-2007, 04:37 PM
Thread: Got a lemon from York
by bertqc- Replies
- 25
- Views
- 1,628
A coil completely frozen means you have enough...
A coil completely frozen means you have enough refrigerant in your system since humidity will be ther only if there is refrigerant changing state. If it the coil is not completely frozen then it may...