    So first off let me say thanks for all the great...

    So first off let me say thanks for all the great info second before i mess with the txv i would like to clean the condensor. From the info i have gathered here no seems to remember the last time the...
  2. Replies
    39
    Views
    2,273

    Before putting out this thread i knew to get all...

    Before putting out this thread i knew to get all my ducks in a row. I went back to the PT CHART and can not believe i made that mistake. To answer a few questions i am right out of school working in...
  3. Replies
    39
    Views
    2,273

    walk in freezer

    The call was evaporator all froze up. The unit had its fans turned off to the evaporator so i defroster the evaporator and turned the unit on but it seems to me the system is overcharged. The unit is...
  4. Replies
    10
    Views
    633

    so i am getting 0 superheat at the evaporator and...

    so i am getting 0 superheat at the evaporator and 80 degrees at the compressor.
  5. Replies
    10
    Views
    633

    box temp right now is 0 degrees suction pressure...

    box temp right now is 0 degrees suction pressure is 5" evaporator outlet temp 0 high side pressure is 112 high side temp before the condensor is 170 outlet temp of the condensor is 68 water into the...
  6. Replies
    10
    Views
    633

    you know your right i took these measurements to...

    you know your right i took these measurements to quickly after startup. I had the compressor off for an hour or two to make sure of no frost. The box temp was probably 10f and on the way up when i...
  7. Replies
    10
    Views
    633

    low temp freezer

    Little nervous doing a low temp freezer first time using MP-66. The suction pressure is 2"hg discharge pressure is 112.
    temp out of the evaporator is 28 discharge temp out of the condensor is 77....
  8. Replies
    14
    Views
    2,296

    thanks

    thanks
  9. Replies
    14
    Views
    2,296

    went looking for a wiring diagram and of course...

    went looking for a wiring diagram and of course there is none to be found i have e-mailed the manufactor to get one. To answer a few questions that i left out when i got there the pressure control...
  10. Replies
    14
    Views
    2,296

    reach in cooler

    First post so i will try to give as much information as i can. It is a Traulsen reach in double door cooler it is using R-22. The call i recieved was the unit had frozen the cheese in the cooler. My...
  11. Replies
    8
    Views
    790

    found small leak by the txv.

    found small leak by the txv.
  12. Replies
    8
    Views
    790

    warm freezer

    working on a meat freezer normal temp -10 it is now running at 20. the unit has mp-66 in it with a water cooled condensor. what should i be looking for low side and high side pressures right now it...
  13. Replies
    3
    Views
    459

    will do i replaced it but i just did not want to...

    will do i replaced it but i just did not want to throw it away with out investigating the why.
  14. Replies
    3
    Views
    459

    honeywell t-stat

    i have a honeywell pnuematic t-stat, when set temp and desired air temp match i get a very high pitch noise. do i replace or can i clean one of the air ports in it.
  15. Replies
    7
    Views
    843

    pump down

    building engineer who sort of inherited this problem. closed reciever valve suction pressure would not hold, so do i shut the sucion valve to figure out if its the pump down or the valves on the...
  16. Replies
    7
    Views
    843

    cycling time

    I have a walk in vegtable cooler it runs on mp 39 the systems runs extremely well until you get down to temperature, then it starts to cycle badly. It has a snap acting temp control in the box and...
  17. Replies
    1
    Views
    534

    cycling time

    I have a large vegtable cooler, it runs off MP_39. Everything runs fine until it gets down to temperature then it starts to short cycle. It has a snap acting temp control that closes when it reaches...
  18. Thread: confused

    by justtrying
    Replies
    4
    Views
    685

    confused

    I will try to explain this best i can. I have two small refrigerators both with there own txv and evaporators. They share the same compressor and condensor. one of them is running at 36 degrees the...