Search:

Type: Posts; User: incontrol

Page 1 of 17 1 2 3 4

Search: Search took 0.02 seconds.

  1. That may be your first problem. Have you seriusly...

    That may be your first problem. Have you seriusly reviewed other manufacturers and rejected them for some reasons? You didn't mention what type of system is there now. It looks like you are getting...
  2. Replies
    6
    Views
    417

    Viewbuilder? Where can I find out more.

    Viewbuilder? Where can I find out more.
  3. Thread: union

    by incontrol
    Replies
    28
    Views
    811

    Well they did. I don't know what to tell you. ...

    Well they did. I don't know what to tell you. I'm not blindly bashing unions; my point was there are very few rules on what they can and can't do. There is no rule you can't make techs pay for oil...
  4. Replies
    0
    Views
    67

    Niagara R2 log question

    In Workplace Pro I can right click on a log link and get go> Log Graph, Log Table options. When I look at it through a browser I don't get those options, only clear. Is there any fix. Version 522
  5. Thread: union

    by incontrol
    Replies
    28
    Views
    811

    Well if you are interested I will tell you why I...

    Well if you are interested I will tell you why I was not thrilled. I had always known that we nonunion people have always had to pay higher prices for things because of the unions, so it cost me...
  6. Thread: union

    by incontrol
    Replies
    28
    Views
    811

    I was in it and will bash it all day long. Scabs...

    I was in it and will bash it all day long. Scabs heal.
  7. Replies
    2
    Views
    189

    How is the ASD wired? Does it go to a jace or a...

    How is the ASD wired? Does it go to a jace or a GCM? If there are any PEMS on the bus ut has to be slowed to 9600 baud.
  8. Replies
    7
    Views
    380

    You'll find out when you apply for jobs. I don't...

    You'll find out when you apply for jobs. I don't know if a DV matters too much. The sex offender may have restrictions on it.
  9. Thread: union

    by incontrol
    Replies
    28
    Views
    811

    You can probably expect to be held back at a...

    You can probably expect to be held back at a lower level as long as they can keep you there. The more you make the less they work you.
  10. What is the exact current configuration? Is...

    What is the exact current configuration? Is there glycol? Do they go around and drain them for the winter? when and how do the pumps currently operate?
  11. Replies
    1
    Views
    137

    shower plate question

    I know, techincally it's not a plumbing site but I can't find a replacement for this shower plate and the HVACTALK crowd is so smart I though someone might know what brand it is or where I can get...
  12. Replies
    2
    Views
    216

    What do you use XIF files for?

    I've been doing programming for several years and have never used one.
  13. Replies
    5
    Views
    280

    Those switches are perfect!

    Those switches are perfect!
  14. Replies
    6
    Views
    372

    That's why we're all here Bro. Someone was...

    That's why we're all here Bro. Someone was looking for an ethernet to headphone cable because they didn't have a sound card. Doh!
  15. Replies
    0
    Views
    155

    Anybody know what Seasuite is doing?

    seasuite.com Anybody know what Seasuite is doing from a harware or programming level? I saw them on tastytrade.com
  16. Replies
    27
    Views
    1,224

    You can polish a turd. ...

    You can polish a turd. https://www.youtube.com/watch?v=3rax27_ZIVM
  17. Replies
    20
    Views
    2,497

    you may try...

    you may try http://ipaddress/ord?spy:/sysManagers/licenseManager I believe *=open
  18. Replies
    1
    Views
    144

    R2 resetable reset

    Is there a way the customer can change his hot water reset in R2? The math Reset block is fixed and cannot accept a setpoint.
  19. Replies
    117
    Views
    2,764

    That's why you get 120 to ground and 208 between...

    That's why you get 120 to ground and 208 between the two legs. They are 120 degrees apart. Pythagorean magic.
  20. Replies
    27
    Views
    951

    I was on-call one night and got called to a...

    I was on-call one night and got called to a factory recip chiller down. Replaced the contactor and fired it up. WHOA you want to talk about Niagara Falls flooding. The discharge had ice on it! I...
  21. Replies
    5
    Views
    280

    Having hard time finding strapon limit

    I need a strapon limit switch about 120 degrees to strap to a pipe. Electrical leads a plus instead of terminals. I'm trying to avoid the big name boxes with remote capillarys. Something in the...
  22. Replies
    117
    Views
    2,764

    When using 2 wires of the 3 hots available you...

    When using 2 wires of the 3 hots available you are using ONE (single)phase. A-B is one phase, B-C is one phase, and A-C is one phase. Your load is not using the neutral so it doesn't count. These 3...
  23. What are you doing with your Bacnet shield terminations?

    Some of our guys insist the shield should be grounded at one end and never terminated on a device. I am sure if I called tech support with a problem one of their first questions will be 'did you...
  24. I sent you an email Neon but it got rejected. Do...

    I sent you an email Neon but it got rejected. Do you have a different email?
  25. Replies
    9
    Views
    287

    I got it now. The bar feature doesn't work with...

    I got it now. The bar feature doesn't work with binaries but the Discrete Area does about the same thing. Thanks!
  26. Replies
    9
    Views
    287

    Nothing under 3.8

    Nothing under 3.8
  27. Replies
    7
    Views
    455

    The fan is running wild? What is your static...

    The fan is running wild? What is your static pressure? I would think the first step would be just put a controller on the duct and wire it straight to the VFD. Later on you can route it to a...
  28. Replies
    9
    Views
    287

    ? The only options are Time Range, Title, Grid...

    ? The only options are Time Range, Title, Grid Lines, and Rollup.
  29. Thread: StruxureWare

    by incontrol
    Replies
    12
    Views
    690

    Can we vote on this? One of their guys called it...

    Can we vote on this? One of their guys called it a Jace. He said it was a java application so that made it a Jace.
  30. Replies
    9
    Views
    287

    I am interested in how to change the binary...

    I am interested in how to change the binary history from a zigzag line to bars.
  31. Replies
    7
    Views
    455

    How in-depth do you want to go? As far as the...

    How in-depth do you want to go? As far as the VFD you don't need any communication at all, you just need a static transmitter. How are they controlling it now? The only issue with no...
  32. Replies
    7
    Views
    277

    I dug this up from tech support a few years...

    I dug this up from tech support a few years ago.....
    ---------------------
    Purchase the B&B Converter with associated power adapter.

    Port Powered RS-232 to RS-485 Converter (Part Number...
  33. Replies
    11
    Views
    1,079

    "to keep other contractors out"

    Quote from our office as to why we are tearing out a newer Niagara system and installing our propriety system for a new addition.
  34. What version are you running and what do you mead...

    What version are you running and what do you mead by 'didn't work very good'? Does the station start? What does the output window say? Are the IPs set as static? Are the necessary ports,...
  35. Replies
    12
    Views
    744

    I just made regular graphics and they look fine...

    I just made regular graphics and they look fine on Iphone or Ipad. You can zoom in for a better look at certain things if needed. It's really cool to be sitting in a mezzanine and watching the...
  36. Replies
    5
    Views
    446

    I've used the LVis before. We put some on...

    I've used the LVis before. We put some on individual ahus. Pretty easy once you get the hang of it. Nice display
  37. Thread: BBMD vs VPN

    by incontrol
    Replies
    43
    Views
    3,221

    We deal with a lot of places like jails and...

    We deal with a lot of places like jails and schools that will not give us VPN privileges. I am trying to set up one school now with BBMD. They have a server address of say 198.xxx.xxx.xxx and the...
  38. Replies
    3
    Views
    395

    What Bacnet spped do you set?

    If I've got a big job should I run it faster to handler more data or slower to help prvent errors? Why would you choose one speed over another?
  39. Replies
    33
    Views
    2,275

    My point a while ago was that if the customer is...

    My point a while ago was that if the customer is not pleased with his system there may be nothing I can do. He may have been told his system was an "open" system because it has some bacnet...
  40. Replies
    12
    Views
    744

    Well that's the reason I'm asking. Everything...

    Well that's the reason I'm asking. Everything looks great and I am just using normal pages. Is there any way an Apple user can have the abillity to change setpoints or overrides?
  41. Replies
    0
    Views
    137

    AX alarm handler has Amnesia

    If the alarm handler is up and running I can get alarms. As soon as I navigate away it looses all the alarms. It used to work ok. Also when an alarm clears I can't tell when it initially went off.
  42. Replies
    12
    Views
    744

    AX Ipad / cell phone users

    Running 3.8. I see there are different Mobile web profiles but I'm not sure what they all do. Does AX know that a mobile is being used and apply that profile? I see there are things like Appliance,...
  43. Replies
    33
    Views
    2,275

    Anything that is not specifically spec'd as...

    Anything that is not specifically spec'd as Tridium will end up some propietary head end and we are going to be back in the same mess we were before. The customers are going to be told they have an...
  44. Replies
    9
    Views
    589

    Think of it as above 35 OA the stat is sent to...

    Think of it as above 35 OA the stat is sent to the valve, below 35 the stat is sent to the bypass.
  45. Replies
    9
    Views
    777

    As an employer that has conducted interviews I...

    As an employer that has conducted interviews I would say attire is not that important. I can't tell you how utterly disgusted I was with the lack of the most basic industry knowledge of applicants....
  46. Replies
    10
    Views
    975

    There are lots of suppliers that offer ' lunch...

    There are lots of suppliers that offer ' lunch and learn' kind of things. Go to those as often as you can. New product demo days are often free. You may want to fork out $ to take a beginner level...
  47. I just want to animate line color in AX.

    I want a boolean to change a line color. Seems like that should be easy enough but when I try to animate it the selection is greyed out.
  48. Thread: PEM Program

    by incontrol
    Replies
    2
    Views
    264

    Where are you gettting this application name...

    Where are you gettting this application name from? I think all pems are manually programmed and there are no supplied standard applications. I can look at it if you email it to me. Have you studied...
  49. Great! I did something like that. When I set...

    Great! I did something like that. When I set the font to 0 it moved up the condition, not allowing space for my temp. I changed the font color to my background to make it disappear.
  50. How can I get rid of the temperature in the AX current conditions?

    If I doubleclick Current Conditions in the weather service it shows a cloud with the temperature and the word Overcast. I like the cloud and condition but I would like to replace the weather service...
Results 1 to 50 of 838
Page 1 of 17 1 2 3 4
Comfortech Show Promo Image