Search:

Type: Posts; User: Dustykyle

Search: Search took 0.00 seconds.

  1. Replies
    21
    Views
    2,145

    Yeah I was non union for 10 years but you just...

    Yeah I was non union for 10 years but you just can't beat the pay 1st year 17.00 hour with a 27.88 dollar package, 2nd year 19.53 with a 31.14 package, and so on until a journeyman 36.17 an hour with...
  2. Replies
    21
    Views
    2,145

    Yeah I was non union for 10 years but you just...

    Yeah I was non union for 10 years but you just can't beat the pay 1st year 17.00 hour with a 27.88 dollar package, 2nd year 19.53 with a 31.14 package, and so on until a journeyman 36.17 an hour with...
  3. Replies
    21
    Views
    2,145

    Yes I will be starting out doing pm's then have...

    Yes I will be starting out doing pm's then have my own truck doing some light duties working under a couple journey men, no pun intended please! Lol.. Have to serve my apprenticeship year after year...
  4. Replies
    10
    Views
    2,475

    New carrier unit installed

    316071316081Over this summer at my families cottage someone stole the condenser. So I thought I would make it a little harder for some one to snatch and grab this one. I started with a 8 inch...
  5. Replies
    21
    Views
    2,145

    Starting at a union shop need some advice

    Well I finally I'm going to start at a union shop doing commercial and industrial maintenance and service. I'm starting from the bottom as a first year apprentice. But I will be on my way to the big...
  6. Replies
    18
    Views
    2,191

    On some units besides the service ports, you may...

    On some units besides the service ports, you may find an extra port...ie pressure tap ,ect.
  7. Replies
    18
    Views
    2,191

    Self piercing valves are for DIY home owners,...

    Self piercing valves are for DIY home owners, under bid jobs, or lazy techs. They do not exist in refrigeration systems.
  8. Thanks for the link, bro:grin2:

    Thanks for the link, bro:grin2:
  9. Replies
    8
    Views
    1,921

    Did you charge the system with more freon,...

    Did you charge the system with more freon, generally a new condenser only comes factory charged with enough freon for a15 foot line set. And if you did what was your super heat and sub cooling. Under...
  10. Replies
    19
    Views
    3,247

    I know I installed a mini split that was a...

    I know I installed a mini split that was a ceiling mount, can't really rember the name brand tho. But they are out their :cheers:
  11. Replies
    10
    Views
    1,228

    Try lowering down the fan speed if you haven't...

    Try lowering down the fan speed if you haven't done so already, should loose humitity so the house will feel less muggy. Factory set system should have been high cool, check and confirm. If so change...
  12. Replies
    26
    Views
    4,775

    Just picked up the jb super nova, tho if the blue...

    Just picked up the jb super nova, tho if the blue vac was available I would have liked to have that one. I like the leak rate indicator feature.
  13. Replies
    9
    Views
    1,102

    First he should be made aware of the cost, then...

    First he should be made aware of the cost, then make the customer sing an invoice,that should implement a lein clause in the invoice if not paid with in 30 days. Add an extra 2 percent to the bill...
  14. Replies
    41
    Views
    3,298

    Also I think I never had a problem to begin with...

    Also I think I never had a problem to begin with my pressures we all weird because the txv bulb was just in the wrong location. And the txv was not opening all the way. I will find out tomorrow. Only...
  15. Replies
    27
    Views
    2,201

    That's a big 10-4, appreciate your thoughts.

    That's a big 10-4, appreciate your thoughts.
  16. Replies
    27
    Views
    2,201

    :whistle: Thanks

    :whistle:

    Thanks
  17. Replies
    41
    Views
    3,298

    Really thanks for all the feed back guys, I think...

    Really thanks for all the feed back guys, I think i just need to chill out pull a nice long vac charge up the system get my super heat and sub- cooling and go from their.
  18. Replies
    27
    Views
    2,201

    I mean it's the only adjustment I could make...

    I mean it's the only adjustment I could make right.
  19. Replies
    27
    Views
    2,201

    Ok not to sound like a complete idiot but getting...

    Ok not to sound like a complete idiot but getting the sub-cooling up. You would just have to add more freon correct.
  20. Replies
    27
    Views
    2,201

    Glad to get all the feed back from this site, I...

    Glad to get all the feed back from this site, I hope one day I can contribute to someone less experienced, such as myself.
  21. Replies
    27
    Views
    2,201

    Sometimes I just over think things, and make it...

    Sometimes I just over think things, and make it harder than it really is. I don't have a long enough service background. Mostly just installs, so when a problem occurs I freak. Like I don't know what...
  22. Replies
    27
    Views
    2,201

    Yeah I think you are right, just got off the...

    Yeah I think you are right, just got off the phone with a friend from Arizona. He suggests I put a hard start kit on the condenser. He thinks that the compressor is not giving the txv enough boost to...
  23. Replies
    27
    Views
    2,201

    The compressor is brand new. High efffecent with...

    The compressor is brand new. High efffecent with the big coils.
  24. Replies
    27
    Views
    2,201

    The lines that were their we're three quarter and...

    The lines that were their we're three quarter and three eights. My condenser size was five eights so I ended up makeing all my custom bends with five eights about three feet or so then slipping the...
  25. Replies
    27
    Views
    2,201

    So you are suggesting to put more freon in the...

    So you are suggesting to put more freon in the system, and that should raise my sub-cooling. Yes humitity is present.
  26. Replies
    27
    Views
    2,201

    Are you refering to the valves off the condenser...

    Are you refering to the valves off the condenser they are fully open.
  27. Replies
    27
    Views
    2,201

    Condenser is a carrier and the coil is a match it...

    Condenser is a carrier and the coil is a match it said a 1.5 to 3 ton coil
  28. Replies
    27
    Views
    2,201

    Yeah new condenser and coil.

    Yeah new condenser and coil.
  29. Replies
    27
    Views
    2,201

    High suction?

    Installed a new r22 w/txv used old line set. Only got a 520 micron pull on system. Went to start up the unit. I only got a 10 degree difference in temp.

    The low side was at 100 psi witch is around...
  30. Replies
    41
    Views
    3,298

    Right on man thanks

    Right on man thanks
  31. Replies
    41
    Views
    3,298

    No man its a brand new pump, and it pulls down it...

    No man its a brand new pump, and it pulls down it just does not hold a vac when the pump is turned off and valved off.
  32. Replies
    41
    Views
    3,298

    Yeah but with brand new hoses. I mean what the f....

    Yeah but with brand new hoses. I mean what the f. I will hook up micron gauge directly to pump with a brand new 5 inch hoses that has a valve on it. When I get down past 500 and turn valve off to...
  33. Replies
    41
    Views
    3,298

    Well I recovered the charge changed the liquid...

    Well I recovered the charge changed the liquid line filter replaced, picked up a new micron gauge, with a new compound gauge set. But that micron gauge didn't even hold under 500 hooked up directly...
  34. Replies
    41
    Views
    3,298

    When I recover the 410 a should I reuse the same...

    When I recover the 410 a should I reuse the same freon or start with virgin stuff?
  35. Replies
    41
    Views
    3,298

    Copy that!

    Copy that!
  36. Replies
    41
    Views
    3,298

    Thanks for the reply six you made me able to...

    Thanks for the reply six you made me able to sleep tonight. I rather look like a fool then have to replace a condenser.
  37. Replies
    41
    Views
    3,298

    I dont know something just did not seem right I...

    I dont know something just did not seem right I think I would feel better just buy a new micron gauge and just starting over. Don't want to chance it. I dont think I have any leaks in the system...
  38. Replies
    41
    Views
    3,298

    Thanks for the fast reply, I never did a drive by...

    Thanks for the fast reply, I never did a drive by yank of a disconnect before. It ran for about 26 hours do you think I did any damage?
  39. Replies
    41
    Views
    3,298

    Well when I pulled a vac i only got down to 600...

    Well when I pulled a vac i only got down to 600 microns I opened the valves and went and turned the system on. Now the unit isn't cooling properly on about 12 degrees differantal. I'm thinking my...
  40. Replies
    41
    Views
    3,298

    I think I got air in the system

    How bad is it for a system to run with air in it, do you think it would be ok if the system ran for a wile? with out damaging the equipment?
  41. Replies
    3
    Views
    776

    Micron gage not holding

    I just noticed today I tested my micron gage with brand new hoses, valved off the gage after 500 and the dam thing didnt hold, would you say I have a leak in my gage? It's a supco.
Results 1 to 41 of 41