Search:

Type: Posts; User: Rmarshall

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    1
    Views
    434

    Ductless Heat Pump question

    Hello group,

    Ductless Heat Pump question. I was on the horn with Sanyo the other day on a multi split system we put in, and they told me they superheat requirement at the service valve and I...
  2. Replies
    1
    Views
    228

    Merry Christmas Everyone

    Wanted to wish everyone a Merry Christmas and Happy New Year. Thanks to everyone for all the help throughout the year

    Rob

    www.AdvancedHeatingpdx.com
  3. Replies
    4
    Views
    1,696

    Never mind I fixed it :) this new system was just...

    Never mind I fixed it :) this new system was just a little intimidating is all working on a system for the first time, while all the control guys wanted to change out boards for thousands of dollars....
  4. Replies
    1
    Views
    532

    Never mind I fixed it :) this new system was just...

    Never mind I fixed it :) this new system was just a little intimidating is all working on a system for the first time, while all the control guys wanted to change out boards for thousands of dollars....
  5. Replies
    2
    Views
    737

    Differential pressure switch that makes sense...

    Differential pressure switch that makes sense from multiple locations that easily explains why it's there in the burner box. Thanks bro
  6. Replies
    1
    Views
    532

    York Millenium Metasys system.... Help

    Hey Guys I previously posted a thread on help with this York JCI system, and first time working on this type of system so I'm in above my head, and I hate asking questions only to learn a little more...
  7. Replies
    2
    Views
    737

    Carrier 58sx furnace

    Hey group question on a Carrier furnace. Lines coming off pressure switch. Pressure switch on bottom and line connects to box by IM which closes switch. Bit there's another line that comes on...
  8. Replies
    4
    Views
    1,696

    Thanks Basparky. Berg it's a York gas pack...

    Thanks Basparky. Berg it's a York gas pack #Z23an22n7kavcma and there is 13 vav boxes Johnson Control # tsseh with auxiliary heat. Now we had the JC guy out and the software wasn't reading any...
  9. Replies
    4
    Views
    1,696

    Johnson Control Metasys system

    Hey Guys,

    I'm wanting to learn about the Metasys Control system, and I don't have a clue. I was on a job yesterday with a York gas pack with 13 vav boxes tied into a Metasys system and wanting...
  10. Replies
    4
    Views
    713

    Trane A/H m#tam7aoc36h31saa help

    Hey guys,

    I'm not a Trane dealer and can't find lick about this air handler on there site. Anyone help? Is this just a standard air handler? Anything communicating on this? Sub contactor of mine...
  11. Replies
    13
    Views
    977

    Ya Dan tgatsalrwady been established by earlier...

    Ya Dan tgatsalrwady been established by earlier posts. Brain fart answer I didn't word my question right
  12. Replies
    13
    Views
    977

    Ya thanks JP that makes sense. I was like shoot...

    Ya thanks JP that makes sense. I was like shoot how do u check it? It's cause they never seem to break in any way other than open windings or a dead short and anything else is loud noise and amps....
  13. Replies
    13
    Views
    977

    Oh ya no **** lol! I should wake up before I post...

    Oh ya no **** lol! I should wake up before I post stuff lol. What's the best way to check a scroll that's operating vorrectly
  14. Replies
    13
    Views
    977

    Checking the valves on a scroll

    Morning guys. How do I check the valaves on a scroll compressor? And exactly why does suction pressure come right up compared to a regular compressor?

    Thanks guys

    RIP Al Davis
  15. Replies
    2
    Views
    1,229

    Thanks Vegas. Ya I got the starting off backwards...

    Thanks Vegas. Ya I got the starting off backwards and delay. The cob webs and pine needles surrounding the motor sure seem like it hasn't ran in a while :) I'll get that fitting from my supply house...
  16. Replies
    2
    Views
    1,229

    Trane xl 15i condenser fan motor issue

    Hey guys, can anyone give me a 101 on ECM condenser fan motors? Don't know much bout them and had a call today on a Trane that wasn't working. It was 3pm and didn't put that much effort into it ;) it...
  17. Replies
    24
    Views
    6,805

    Sensor

    Got it. Called distributor Red=X Black=Fan Blue= common. Dis regard previous posting thats what I get for listening to someone elses posting on here :)
  18. Replies
    24
    Views
    6,805

    Sensor

    Oops bue-common red-fan Black termination
  19. Replies
    24
    Views
    6,805

    Sensor

    Guys,

    Can you tell me what the leads are on this sensor? Red Blue, & Black? And my supplier has another sensor red, blue & brown? Both the same. Sorry if Im late on this posting

    Thanks
  20. Replies
    9
    Views
    1,944

    1 of the 2 :) I gotta see if there is support and...

    1 of the 2 :) I gotta see if there is support and thanks for your help much appreciated
  21. Replies
    9
    Views
    1,944

    Any chance you have a troubleshooting guide for a...

    Any chance you have a troubleshooting guide for a hfe1009ndf-ul head?

    Thanks for your help
  22. Replies
    9
    Views
    1,944

    Ya I know. Number wasn't any good on fedders...

    Ya I know. Number wasn't any good on fedders operation book and no info at all online except fedders is the bottom of the barrel when it comes to mini splits. I guess I'll wait till tomorrow and try...
  23. Replies
    28
    Views
    2,198

    I understand the difference on fixed orfice/...

    I understand the difference on fixed orfice/ superheat vs txv/ sub cooling now :) just takes me a minute or two to think about how the refrigeration systems works and the txv and how it affects the...
  24. Replies
    9
    Views
    1,944

    Thanks Bebe I should of mentioned model #s...

    Thanks Bebe I should of mentioned model #s hfc1009n2ful And hfe1009ndful it's a 6wire control system not a 4 wire. I can't find any info and heck the number doesn't even work to call them
  25. Replies
    9
    Views
    1,944

    Fedders ductless Heat Pump help

    Working on a fedders ductless heat pump, first time on this brand. Different then regular ductless I work on. This has 6 control wires from HP going to indoor head vs normal 3 I usually see. But it's...
Results 1 to 25 of 47
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event