  1. Replies
    40
    Views
    3,753

    Just wondering when you had the air handlers...

    Just wondering when you had the air handlers hooked to B & C then moved to A & B you did move the line set from C to A I hope.
  2. Replies
    31
    Views
    2,550

    Dam What a Hack!!!!!

    Dam What a Hack!!!!!
  3. Replies
    40
    Views
    3,753

    If you do not have any of the wires from the air...

    If you do not have any of the wires from the air handlers crossed up I would be looking at the grounding. All mini splits can and do get stupid if not grounded properly.
  4. Replies
    40
    Views
    3,753

    The led will stop and start again. Number of...

    The led will stop and start again. Number of blinks after stop is the fault code.
  5. Replies
    40
    Views
    3,753

    What are the flash code on the Operation LED and...

    What are the flash code on the Operation LED and on the Timer LED?
  6. Replies
    40
    Views
    3,753

    OK check on the earth grounding to the system. We...

    OK check on the earth grounding to the system. We have in the past had to add an earth ground with in 3' of the condenser. Best of luck.
  7. Replies
    40
    Views
    3,753

    You may have to cut power to the condenser and...

    You may have to cut power to the condenser and hold untill all leds go out for the computer to reset. When fujisu is powered up it runs a scan to know what it hooked up to it.
  8. Replies
    40
    Views
    3,753

    Did you ever wonder why they are marked A B C?

    Did you ever wonder why they are marked A B C?
  9. Replies
    21
    Views
    2,743

    Is the LG cooling only or Inverter ?

    Is the LG cooling only or Inverter ?
  10. Replies
    4
    Views
    611

    looks like you have found the problem. hook up...

    looks like you have found the problem. hook up recovery. Keep learning.
  11. Replies
    43
    Views
    2,398

    Check with Heil for 24" back sweep fan blade lot...

    Check with Heil for 24" back sweep fan blade lot less sound. AT 71dba you have a long way to go to get 40. Good luck
  12. Replies
    2
    Views
    438

    Yes it keeps the sman3 from getting beat up in...

    Yes it keeps the sman3 from getting beat up in the van.
  13. Replies
    28
    Views
    1,605

    Sman 3 Love it.

    Sman 3 Love it.
  14. Replies
    10
    Views
    3,723

    Go to www.forwardthinking.honeywell.com As I...

    Go to www.forwardthinking.honeywell.com As I remember from the webcast with Nordyne the gateway is like any wireless hub.
  15. Replies
    3
    Views
    416

    R 4.5 or 2" in conditioned area and R 8 or 3" in...

    R 4.5 or 2" in conditioned area and R 8 or 3" in unconditioned.
  16. Thread: UTL Ductless

    by tcktech
    Replies
    2
    Views
    1,160

    Check your install manual. The inverter type unit...

    Check your install manual. The inverter type unit has high voltage from outdoor to indoor. We use 14/4. High voltage Low amp.
  17. Replies
    6
    Views
    584

    Have had mine for about 30 days not one problem....

    Have had mine for about 30 days not one problem. I love working with it.
  18. Replies
    5
    Views
    758

    Just got my new Sman3 from supply house Monday...

    Just got my new Sman3 from supply house Monday Noland Co. $320.00 +tax. Nice set up.
  19. Replies
    6
    Views
    622

    Hoping the Sman3 is all you guys say it is. Still...

    Hoping the Sman3 is all you guys say it is. Still wating for mine to get hear. Supply co. ordered me one, said I might have it by Christmas Ha Ha.
  20. Replies
    32
    Views
    2,512

    Are you talking about Inverter type unit?

    Are you talking about Inverter type unit?
  21. Thread: Wire size

    by tcktech
    Replies
    29
    Views
    2,465

    Run two 6awg and one 8awg ground. on a 50 amp....

    Run two 6awg and one 8awg ground. on a 50 amp. cya.
  22. Replies
    13
    Views
    4,442

    I have been using a pullzall from warn works that...

    I have been using a pullzall from warn works that I bought from tractor supply. 115v only 15lb. with a 15ft wire rope does a fine job on compressors and lifting air handlers in to the attic.
  23. :eek:From the look of the blower and motor end...

    :eek:From the look of the blower and motor end that unit needs a full clean by a HAVC Pro. The Coil will be pig dirty. Cleaning crews have no clue as to AC work. It will be costing you on elect....
  24. Replies
    45
    Views
    2,581

    Have a Pro come out and do a full chem. clean on...

    Have a Pro come out and do a full chem. clean on your system, check charge, air flow and all. A lot of home owners do not think about maintance on the AC untill it does not work. If your unit is 3-4...
  25. Thread: Water temp

    by tcktech
    Replies
    95
    Views
    9,260

    :confused:Are your two systems runing off of one...

    :confused:Are your two systems runing off of one well system, or are there two? If the two are runing off one are check valves and flow valves installed at each set of pumps? I would still be looking...