  1. Check the temperature split between the return...

    Check the temperature split between the return air temp and supply air temp. If its more than 20 you need more airflow.
  2. Replies
    1
    Views
    63

    Put it on a scale and see if it weighs 4000 lbs....

    Put it on a scale and see if it weighs 4000 lbs. I bought a 5 tom for my house. It was supposed to weigh 10,000 lbs. It only weighed 560 lbs. I took it back and told them they cheated me.
  3. Replies
    183
    Views
    3,786

    All I know is what I see. The info I presented is...

    All I know is what I see. The info I presented is what was in front of me. All I can say.
  4. We do bare copper through a pitch pocket....

    We do bare copper through a pitch pocket. Insulate before and after.
  5. Replies
    6
    Views
    110

    What was your superheat and subcooling?

    What was your superheat and subcooling?
  6. Replies
    15
    Views
    467

    At home all I had was a 1625 1/2. LoL I had the...

    At home all I had was a 1625 1/2. LoL I had the most noisy fan on my street. I didnt leave it that way. Its all I had on the truck and I didn't want to drive to the warehouse.
  7. Is the air coming out "Beer can cold"?

    Is the air coming out "Beer can cold"?
  8. As stated above. Be sure all the vents are open...

    As stated above. Be sure all the vents are open in the offices, check return grills and filters to be sure they are clean. Check the blower wheel and be sure the cups are not full of dirt and old...
  9. Replies
    9
    Views
    333

    49 degrees yesterday morning! i was just waiting...

    49 degrees yesterday morning! i was just waiting for a furnace call.
  10. i personally prefer copeland any day over...

    i personally prefer copeland any day over everything else.
  11. Replies
    15
    Views
    467

    I have put 1075's on 810 and 825 rpm units. Never...

    I have put 1075's on 810 and 825 rpm units. Never noticed any ill effects. Probably improves subcooling on hotter days and better heat scavenging on heat pumps.
  12. I have one in a store. I converted it to R22 a...

    I have one in a store. I converted it to R22 a while back when the we changed the compressor and txv's. We are using a paragon timer defrosting 4 times per day for 50 min. It keeps most of the ice...
  13. Replies
    35
    Views
    820

    Put a potential relay and a 1,0000000000000 uf...

    Put a potential relay and a 1,0000000000000 uf cap will start it lol
  14. Replies
    15
    Views
    467

    A 1/4-1/2 1075 fixes everything.

    A 1/4-1/2 1075 fixes everything.
  15. I have changed out a few embraco compressors....

    I have changed out a few embraco compressors. Never had any trouble with them. Installed properly they should be trouble free.
  16. Replies
    10
    Views
    513

    Restricted

    Restricted
  17. Replies
    27
    Views
    733

    Lol

    Lol
  18. Replies
    43
    Views
    838

    We have some cold nights on the forecast. I have...

    We have some cold nights on the forecast. I have several compressor changes. Will give us a break from the norm hopefully.
  19. Replies
    27
    Views
    733

    That's definitely beer can cold. If the dew point...

    That's definitely beer can cold. If the dew point is too low keep adding gas lol.
  20. There will always be enough fixed speed motors...

    There will always be enough fixed speed motors etc available. No worries.
  21. Replies
    41
    Views
    705

    Driers make good cap tubes....have some moisture...

    Driers make good cap tubes....have some moisture in the system and add leak stopper. Keep adding leak stop until your superheat comes up to where you want it.
  22. Replies
    3
    Views
    128

    Its a split system for sure. The coil has two txv...

    Its a split system for sure. The coil has two txv 's split off a 1/2" Liquid line and 1 1/8" suction.

    I believe it is 7.5 tons.

    I am 99.99 % sure.

    Its strange that the system is setup that...
  23. Don't worry. The hacks will be sure 14 seer units...

    Don't worry. The hacks will be sure 14 seer units operate like a 9 seer.
  24. Replies
    3
    Views
    128

    BDP 707coo090000MAAA coil

    Is this a 90,000 btu evaporator?
    It is sitting atop a pair of twinned 90% Payne furnaces connected to a single condenser with a ZR94 scroll compressor.
  25. I push customers hard to do it right. When they...

    I push customers hard to do it right. When they do not have the $$$$ , they don't have it. It is a choice of no air conditioning vs air conditioning that does not run efficiently and no warranty.