  1. Replies
    14
    Views
    1,320

    Yes, it is a retrofit. And the boiler is very...

    Yes, it is a retrofit. And the boiler is very old. We are replacing pneumatic system.
  2. Replies
    14
    Views
    1,320

    I do monitor HW supply temp and alarm it. In the...

    I do monitor HW supply temp and alarm it. In the spec I should provide boiler status and flame failure in addition to water temperature monitoring..
  3. Replies
    14
    Views
    1,320

    Thank you all for your replies. I like the idea...

    Thank you all for your replies. I like the idea of using relay. I'm not sure about current switch: it is really not too much current and the switch could be faulty. I will definitely research both...
  4. Replies
    14
    Views
    1,320

    I see that the working range is 90 - 130 . It...

    I see that the working range is 90 - 130 . It doesn't look that this stat would work.
  5. Replies
    14
    Views
    1,320

    Flue gas sensor

    I need to get a boiler status and flame failure alarm. These point are not available from the boiler. My plan is to install flue gas sensor (or switch) and with some logic indicate required values on...
  6. Thread: Oscilloscope

    by eparizher
    Replies
    17
    Views
    2,499

    By the way, how can you connect one channel scope...

    By the way, how can you connect one channel scope to the com trunk? My understanding that when you connect scope ground to the com wire (that is not ground), you can break the communication because...
  7. Thread: Oscilloscope

    by eparizher
    Replies
    17
    Views
    2,499

    I like Picoscope 2205. What is your opinion?

    I like Picoscope 2205. What is your opinion?
  8. Thread: Oscilloscope

    by eparizher
    Replies
    17
    Views
    2,499

    What model do you have?

    What model do you have?
  9. Thread: Oscilloscope

    by eparizher
    Replies
    17
    Views
    2,499

    The main purpose for the oscilloscope is to see...

    The main purpose for the oscilloscope is to see what is a signal shape, square or sinus wave, level of noise. All basic tasks that allow me to troubleshoot if I have electrical, hardware failure or...
  10. Thread: Oscilloscope

    by eparizher
    Replies
    17
    Views
    2,499

    Oscilloscope

    I'm planning to get a USB (computer based) oscilloscope for troubleshooting BACnet MS/TP, Modbus and Lon networks.
    Can you advise me what parameters should I select for this task.
    So far I think...
  11. Replies
    0
    Views
    554

    Baldor VS1 VFD Modbus Integration

    We have a very fast truck project (Niagara AX) with a lot of integrations.
    Everything is fine except Modbus integration with Baldor VFD drive. I'm getting wrong values or points are in fault.
    Maybe...
  12. Replies
    26
    Views
    1,576

    Thank you, I will take a look.

    Thank you, I will take a look.
  13. Replies
    26
    Views
    1,576

    I don't want to control BO from 50 different...

    I don't want to control BO from 50 different algorithms. I want to create interface that allows to make programming easier, more graphical. After full configuration of the controller the station will...
  14. Replies
    26
    Views
    1,576

    This is just an example. For this particular...

    This is just an example. For this particular object BO it could be about 50 different properties. The same approach applied to other objects with total number of possible properties about 100...
  15. Replies
    26
    Views
    1,576

    My idea to write interface that replace NBPro as...

    My idea to write interface that replace NBPro as much as possible. The reason for this is because if I need to debug a program almost every time I have to do reverse engineering. The same about...
  16. Replies
    26
    Views
    1,576

    Since NBPro is not very user friendly, I try to...

    Since NBPro is not very user friendly, I try to make partial substitution for this tool. Obviously solution with AVs and BVs won't work: too many properties. Also I can't use SPL for anything not...
  17. Replies
    26
    Views
    1,576

    It's exactly what I need. The only thing I still...

    It's exactly what I need. The only thing I still can't write this value from AX. I tried numeric and enum points.
    Getting error
    Property:Invalid Data Type
  18. Replies
    26
    Views
    1,576

    I see some misunderstanding. If I need to read...

    I see some misunderstanding. If I need to read point, I can discover and add point to the database as any type and it doesn't conflict with the controller data type. For example I can add binary...
  19. Replies
    26
    Views
    1,576

    First of all it's not a bag. Whole Automatrix...

    First of all it's not a bag. Whole Automatrix programming based on proprietary properties.
    The point can be discovered as a text in AX if Niagara doesn't know the data type. All other proprietary...
  20. Replies
    26
    Views
    1,576

    My question is how to add writable point to the...

    My question is how to add writable point to the AX to be able to change value from AX. I.e. change input property in the PID object from AI-1 to AI-2.
  21. Replies
    26
    Views
    1,576

    Automatrix proprietary properties

    I try to add AAM proprietary property in Niagara, that has two values in the same property. For example: Analog Output 1 Auto-Stuffing Input object will be AI-1 53041. I can discover this property as...
  22. Replies
    14
    Views
    1,243

    How the communication is established between...

    How the communication is established between controller and the front end? I was under impression that it is a BACnet communication. Am I right or some proprietary property/protocol allows to see the...
  23. Replies
    14
    Views
    1,243

    Thank you. It's what thought. Just curious, why...

    Thank you. It's what thought. Just curious, why make open protocol points private? What stands behind this approach?
  24. Replies
    14
    Views
    1,243

    ALC Integration

    I have to integrate Automated Logic site. There is no problem discovering all controllers (BACnet over IP), but I can't see any points in the controllers. Only system objects and alarms. Also I can...
  25. Replies
    59
    Views
    7,686

    No experience yet, we just plan to have a...

    No experience yet, we just plan to have a training this year and do some small installations.
  26. Replies
    59
    Views
    7,686

    New management level controller/front end....

    New management level controller/front end. Replacement for Tridium JACE/Supervisor.
  27. Replies
    11
    Views
    978

    I've forwarded it to you.

    I've forwarded it to you.
  28. Replies
    11
    Views
    978

    Thank you!

    Thank you!
  29. Replies
    11
    Views
    978

    This module written by Gareth Johnson. I don't...

    This module written by Gareth Johnson. I don't have remote access to the site.
  30. Replies
    11
    Views
    978

    AX globalUser.jar module

    Is anybody can send me globalUser.jar? I have an old project that I want to open on my laptop and this module is missing.
    The email is in my profile.
  31. Replies
    6
    Views
    1,110

    There are 21 controllers total with mix firmware...

    There are 21 controllers total with mix firmware revisions.
  32. Replies
    6
    Views
    1,110

    We had one integration. It works good with new...

    We had one integration. It works good with new firmware, but not old one. Infocon promised us to update the driver in a month. Looks like you have the same issue/
  33. Replies
    20
    Views
    3,893

    If I'm sitting in a classroom, what is the...

    If I'm sitting in a classroom, what is the difference for me if OA CO2 is higher or lower? The comfortable space CO2 level should be around 800-900 ppm. If for some reason OA CO2 (which is typically...
  34. Replies
    20
    Views
    3,893

    Here is a sequence: The classroom CO2 level set...

    Here is a sequence:
    The classroom CO2 level set point should 700 ppm higher then outside air CO2 level. It doesn't make to much sense to me, but I have to submit and program exactly this way.
  35. Replies
    20
    Views
    3,893

    ACI and Telaire don't offer outside CO2 sensor....

    ACI and Telaire don't offer outside CO2 sensor. Senva looks good. Thank you.
  36. Replies
    20
    Views
    3,893

    Outside Air CO2 Sensor

    I have to monitor outside air CO2 level in my project. What could be a good sensor and who is a manufacturer?
  37. It depends. If you talking about connecting...

    It depends. If you talking about connecting blocks, I agree. But if you need to do something more advanced like writing a program block or module, it's better to teach programmer HVAC.
  38. Replies
    12
    Views
    919

    Looks like I found the problem spot. As soon as I...

    Looks like I found the problem spot. As soon as I reset the controller 300, I get communication to 500, 600 and 700. The only problem that after resetting 300 it requires reconfiguration (small...
  39. Replies
    12
    Views
    919

    Thanks, I'll try it tomorrow.

    Thanks, I'll try it tomorrow.
  40. Replies
    12
    Views
    919

    I created new user account for myself with top...

    I created new user account for myself with top level privileges and no restrictions. Obviously I can't check SUA in the controller that I can not communicate.
    I'll be on the site tomorrow and check...
  41. Replies
    12
    Views
    919

    Actually I already checked all NET object....

    Actually I already checked all NET object. Everything is set correctly there.
  42. Replies
    1
    Views
    977

    Never worked with Apogee, but in general instead...

    Never worked with Apogee, but in general instead of discovering schedule in Apogee server you can push it on JACE level. Use BACnet schedule export manager.
  43. Replies
    1
    Views
    491

    My understanding you are talking about Siemens...

    My understanding you are talking about Siemens branded Tridium JACE and/or Workstation. Different license, features and price.
  44. Replies
    12
    Views
    919

    I'm not a Delta dealer and all my access only...

    I'm not a Delta dealer and all my access only through the customer's ORCAview (that eventually goes away as a front end) .
  45. Replies
    12
    Views
    919

    I connect two through IP using ORCAview and...

    I connect two through IP using ORCAview and Niagara. In both cases the result is the same. I can't communicate to 500, 600 and 700 (see attachment), but I can see all three NET2 subnet from these...
  46. Replies
    12
    Views
    919

    Delta network problem

    We have to integrate building with Delta installation. There are 3 system level controllers (BACnet over Ehtenet) and 3 system controllers MS/TP that connected to NET1 on one of Ethernet controllers....
  47. Replies
    4
    Views
    2,008

    Thanks for replays!

    Thanks for replays!
  48. Replies
    4
    Views
    2,008

    Trane damper actuators

    We have to control Trane unit ventilators that came with actuators
    X13611407-01 and X13611005-04.
    I couldn't find any cuts for these actuators. Is anybody can help me with documentation or just...
  49. Thread: Staefa Talon

    by eparizher
    Replies
    4
    Views
    1,240

    You can configure everything in AX. To be more...

    You can configure everything in AX. To be more productive you need Staefa templates. The templates allow to configure everything through the graphic interface.
  50. Replies
    7
    Views
    1,062

    I've sent you animations.

    I've sent you animations.
Results 1 to 50 of 181