  1. Replies
    14
    Views
    800

    Pull the access panel off the economiser hood and...

    Pull the access panel off the economiser hood and verify actuator operation. Also red service lite should be on on uem board. When putting in test mode and nothings working, disconnect the j6 plug on...
  2. Replies
    14
    Views
    800

    Supply air sensor is the problem.Get new SAS or...

    Supply air sensor is the problem.Get new SAS or pull OAS and use it.
  3. Just shut down ckt 1, to dang cold out with...

    Just shut down ckt 1, to dang cold out with windchill at -17* f. Will return at end of week to investigate. Customer happy and occupants in office below condenser happy with noise gone .
  4. OROAB 5-210 R407C on Liebert Remote Condenser.

    OAT 8*. head pressure control making a loud vibrating noise. Is this a sign of internal damage to the valve or diaphram or is it common at this low of ambients
  5. Replies
    2
    Views
    480

    Use existing back support under HE, use new bolt...

    Use existing back support under HE, use new bolt that comes with new unit. Most come with inducer and gas valve if ordered. 1 guy for 4 hours, 1 guy for 8 hours.No crane needed to remove and replace,...
  6. Replies
    2
    Views
    480

    2 guys, 1 for 4 hours and 1 for 8 .No crane...

    2 guys, 1 for 4 hours and 1 for 8 .No crane needed to install , maybe to get on the roof.
  7. Replies
    22
    Views
    1,457

    Does the pilot lite? then go out. IGnition...

    Does the pilot lite? then go out. IGnition control board
  8. Replies
    14
    Views
    1,274

    I wonder if the occupants getting headaches had...

    I wonder if the occupants getting headaches had anything to do with this stupid repair. Must not own any red tags
  9. Had same problem with a unit heater. Copper...

    Had same problem with a unit heater. Copper cleaned, still wouldnt take. Picked up some Silvabrite 100 solder and wahlah, 95% tin 5% silver, problem solved. Stay away from water based flux.
  10. Replies
    2
    Views
    778

    Pull the J7 plug off the UCP .Check your DC...

    Pull the J7 plug off the UCP .Check your DC voltage from J7-2 and J7-9.Apply power and jumper LTB -14 TO LTB -5. Should read 2.8 VDC for heat stage 1.LTB 14 TO LTB 3 HEAT 2 should be 3.71 VDC If the...
  11. Replies
    7
    Views
    761

    I dont know if you meant -.2 I.W.C. , but thats...

    I dont know if you meant -.2 I.W.C. , but thats the spec on that unit.
  12. Replies
    24
    Views
    1,742

    Use your recovery machine and weigh in . Works...

    Use your recovery machine and weigh in . Works every time
  13. Replies
    0
    Views
    212

    Rupp Temp Air MUA

    Anyone with info on where to get a IOM for MODEL CFA-220.
  14. Thread: pump

    by gwoner
    Replies
    6
    Views
    493

    The new impellers come off really easy . Just...

    The new impellers come off really easy . Just remove the dome nut. Most pull off .Havent had to use a puller yet
  15. Thread: coil cleaning

    by gwoner
    Replies
    17
    Views
    1,770

    Water and dirt makes mud. You have to separate...

    Water and dirt makes mud. You have to separate the split coils on the condensers.You will be surprised.What looks clean on the outside is most likely hiding enough cottonwood to knit grandma a...
  16. Looks to me like your insulation on the HE access...

    Looks to me like your insulation on the HE access panel is resting on that particular tube causing a hot spot.
  17. Replies
    45
    Views
    3,463

    What LED's are on when the failure occurs on...

    What LED's are on when the failure occurs on the flow sensor and also what color is the flow proving sensor.Also what is the position of the black dot on the flow sensor.All very important for...
  18. Replies
    45
    Views
    3,463

    If the system is tripping after a short while,...

    If the system is tripping after a short while, check the overloads on the compressor circuit breakers, they come from the factory set to zero, raise to 4 on all compressor c/b.'s, happened to me....
  19. Replies
    22
    Views
    1,678

    Why not just raise the cooling setpoint on the...

    Why not just raise the cooling setpoint on the individual vav box to please each zone thats an issue. This can be done in Tracer.
  20. hold the self terst button in on the bottom of...

    hold the self terst button in on the bottom of the sensor for 2-3 secs. t i think this action resets the sensor.
  21. Replies
    7
    Views
    887

    pull the j7 plug and check terminals j7-8 and 11...

    pull the j7 plug and check terminals j7-8 and 11 to ground for 5 vdc. if not the ucp board is bad
  22. Thread: RTAA

    by gwoner
    Replies
    4
    Views
    593

    i suggest testing the evap temp sensors, both in...

    i suggest testing the evap temp sensors, both in and out. Replace as a pair.
  23. Replies
    7
    Views
    1,537

    The AOP forums/Ask Our Pro's forums, are...

    The AOP forums/Ask Our Pro's forums, are restricted to only Pro members that have been vetted by the AOPC can post advise, questions or commentary in a thread created by someone else. You need to...
  24. Replies
    20
    Views
    1,539

    mini splits

    Did half a dozen of them. No problems in 5 years. Just do it. Better than going home without pay.
  25. Replies
    32
    Views
    2,560

    intellipak

    Never seen or heard of any charges other than R22 or R410A in an Intellipak