08-13-2012, 09:53 PM
Thread: Inside a pipe brazed with nitrogen
by stopro1- Replies
- 16
- Views
- 3,971
300561
300561
-
08-13-2012, 09:20 PM
- Replies
- 22
- Views
- 1,293
furnace bonnet temp (before evap) should be...
furnace bonnet temp (before evap) should be limited to 88F max. This will prevent overloading the indoor coil, which is now in cooling mode, with too much heat. it also should keep discharge air no...
-
08-13-2012, 09:12 PM
Thread: Daikin Operation Question
by stopro1- Replies
- 9
- Views
- 1,386
The EEV in each evap maintains its own superheat,...
The EEV in each evap maintains its own superheat, typically 1-5F. As EEV's open to lower the superheat (when load increases), the suction pressure rises, which tells the compressor to speed up. The...
-
08-13-2012, 08:54 PM
Thread: what size would you do.
by stopro1- Replies
- 27
- Views
- 1,840
What you have is an oversized return and...
What you have is an oversized return and undersized supply for the 2.5-3T system you think is needed. With the oversized blower, and total static of the combined supply/return/registers there, you...
-
07-05-2012, 08:20 PM
Thread: Carrier Infinity Zoning
by stopro1- Replies
- 11
- Views
- 760
Wogpa, thanks. That sounds like a great idea and...
Wogpa, thanks. That sounds like a great idea and may get me close.....2 spd ODU is cooling only and I could connect it as non-communicating instead, but wouldn't dual fuel configuration want to run...
-
07-04-2012, 08:10 AM
Thread: Carrier Infinity Zoning
by stopro1- Replies
- 11
- Views
- 760
kfitman....I'm not sure that you are grasping the...
kfitman....I'm not sure that you are grasping the situation completely. I could very easily do what you describe if I had a conventional system with a 24V AC thermostat and W output connected to the...
-
06-29-2012, 11:06 AM
Thread: Carrier Infinity Zoning
by stopro1- Replies
- 11
- Views
- 760
Thanks for the replies but I'm not understanding...
Thanks for the replies but I'm not understanding completely....
The 4 wires to the smart sensors, zoning panel, furnace and condenser are (2)RS232 data + (1)24vH + (1)24vC. The 24v terminals in... -
06-24-2012, 09:41 PM
Thread: Carrier Infinity Zoning
by stopro1- Replies
- 11
- Views
- 760
Carrier Infinity Zoning
Ok guys, I've been out of the field since before these things came out and moved into commercial service management. Looking for some help from those of you that work with this stuff everyday.
... -
07-14-2011, 06:16 PM
Thread: Andover continuum 866-v vav controller
by stopro1- Replies
- 1
- Views
- 584
Andover continuum 866-v vav controller
Hey guys,
A little out of my league here but I think I may have a room sensor wiring issue.
This controller has a generic stat wired into smart sensor terminals. Seems that smart sensor... -
03-08-2011, 11:08 PM
Thread: AMANA HT WT BOILER INFO
by stopro1- Replies
- 15
- Views
- 2,889
here is the parts list for your model
Model#: ERGW00121A Mfg#: P6819106F
Part Number Description Substitution
A3326003 CLAMP, HOSE
A3326801 GROMMET OBSOLETE
A3335502 STRAP, EXPANSION TANK
A3414405 MANUAL, INSTALLATION... -
02-06-2009, 02:14 PM
Thread: carrier geothermal problem
by stopro1- Replies
- 11
- Views
- 3,104
Sounds like there might not be enough water flow....
Sounds like there might not be enough water flow. Normal water TD in the heating mode should be 10F, 15F max. 12 to 20max in cooling. Also, with 41F entering water, sounds like an open loop using...
-
01-27-2009, 03:46 PM
Thread: Ez Zone Missing zone
by stopro1- Replies
- 7
- Views
- 578
I may have the exact new EZ zone controller. What...
I may have the exact new EZ zone controller. What is your part#?
-
01-27-2009, 03:42 PM
Thread: Loop Water Controller
by stopro1- Replies
- 3
- Views
- 562
Loop Water Controller
Does anybody know who makes a generic LWC? Looking for an alternative to making our own 4H/4C temp ctrl panel with hi/lo alarm and pump lead/lag/flow fail rotation. No interface to WHSP's or external...
-
01-25-2008, 04:04 PM
Thread: tweaking thermostat settings
by stopro1- Replies
- 49
- Views
- 4,804
Hey Lou F
You'd better get that heater looked at. 110 degree rise is a clear indicator that something is wrong. Typically, gas furnaces are rated for 35min to 75 max temp rise through them. You may have an...
-
01-25-2008, 03:56 PM
Thread: Taco zone valve failures
by stopro1- Replies
- 7
- Views
- 7,408
maybe an A14 tip was used to solder the valves in...
maybe an A14 tip was used to solder the valves in without disassembling them first?
-
11-30-2007, 10:45 AM
Thread: Sanyo Split
by stopro1- Replies
- 2
- Views
- 589
a low ambient kit..
is what you may need, not just the board. If your unit requires, the kit may also contain a crankcase heater. Some don't need a heater, but best to check before putting in a board only. Yes, heat...
-
11-13-2007, 07:54 AM
Thread: Bryant Evolution - balance point help
by stopro1- Replies
- 32
- Views
- 2,346
Confusion
There is no reasonable economic balance point where the fossil fuel furnace is more efficient than the heat pump, until it's about -10F outside, when the heat pump's COP is at .95 (equal to the...
-
11-12-2007, 08:51 PM
Thread: Bryant Evolution - balance point help
by stopro1- Replies
- 32
- Views
- 2,346
software? spreadsheet?.....
Balance point is the point where the heat pump's output becomes equal to the heat loss of the structure. With a proper heat loss calc and performance ratings of the equipment, this can be plotted in...
-
10-08-2007, 11:42 AM
- Replies
- 2
- Views
- 642
A residential grade multisplit heat pump....
only has one compressor and one reversing valve. Therefore, there would be no way it can produce heating and cooling at the same time. Also, I believe most brands will require that all tstats be...
-
08-13-2007, 04:02 PM
Thread: Need help with Sanyo Ductless-Split!
by stopro1- Replies
- 12
- Views
- 1,424
The factory charge amount is for 100' (one way)...
that means the length of just one of the tubes. The full factory charge amount must be in the system, not half of it. If single tube length is over 100', then additional refrigerant is needed
The... -
05-07-2007, 05:20 PM
Thread: What's your minimum temperature for A/C?
by stopro1- Replies
- 20
- Views
- 1,797
Wow!- saturated would be the little temperature...
Wow!- saturated would be the little temperature scale thingy on the inside of your gauges or maybe even the temperature on a p/t chart. Scary
-
04-03-2007, 12:56 PM
Thread: Sanyo Eco-G Gas heatpump
by stopro1- Replies
- 1
- Views
- 364
You won't get much response here...
as the Eco-G is not yet available in the U.S. It is a gas engine driven VRF heat pump powered by a precision Nissan engine. Great stuff- can't wait til it's available here.
-
02-07-2007, 09:25 AM
Thread: Dual Side Returns
by stopro1- Replies
- 23
- Views
- 1,289
2000 cfm for heating?
is this a heat pump? It does not sound that way from some things in your posts. If it is a gas or oil furnace as it sounds, it is unlikely that your system needs to move 2000 cfm in heating. Probably...
-
01-28-2007, 11:03 PM
Thread: Poor performance with brand new Trane
by stopro1- Replies
- 74
- Views
- 7,765
won't satisfy last two degrees, compressor cycles....
sounds like the hp may be going off on high head from when it was run to cure mud sanding. have you checked the filter and indoor coil?
as for the sizing, 800 sf/ton is plenty for a home insulated... -
01-21-2007, 12:45 PM
Thread: Old Steam Radiators
by stopro1- Replies
- 4
- Views
- 1,761
check with these guys
http://www.antiqueplumbingandradiators.com/
Results 1 to 25 of 54