  1. Thread: 20T Carlyle

    by bodhisatva
    Replies
    6
    Views
    845

    There's a trap at the low point in the tubing,...

    There's a trap at the low point in the tubing, about two feet long before it turns up. And I added a reverse P-trap at the high point in the vertical rise on the roof. The oil is getting back, I...
  2. Replies
    10
    Views
    981

    It's worth a shot. That being said, if you need a...

    It's worth a shot. That being said, if you need a hard start you're probably going to need a compressor before long. Do your client a favor, recommend a professional, cause you obviously need to be...
  3. Replies
    13
    Views
    2,173

    Are you sure that's the reset button you're...

    Are you sure that's the reset button you're holding in to make it work?

    Here's a thought,... what's the voltage when you measure it after the board and before the motor?

    And,... what was the...
  4. Replies
    29
    Views
    3,312

    yeah, I think your Leon must've all freaked out ...

    yeah, I think your Leon must've all freaked out

    ...sorry,I had to steal it,... just too funny
  5. Thread: 20T Carlyle

    by bodhisatva
    Replies
    6
    Views
    845

    20T Carlyle

    Just replaced compressor in Carrier split system for the second time in six years (well, someone else replaced it the first time). It's a 38AKS024-511 and the compressor is model #06ET250-360. A...
  6. Replies
    10
    Views
    4,679

    I was told at a class by an ice machine company...

    I was told at a class by an ice machine company that pink mold means yeast (like in a bakery app) and black indicates sugar. They sell a chemical pack to mount inside the machines to kill or at least...
  7. Replies
    9
    Views
    966

    use a wet switch http://www.wetswitch.com/

    use a wet switch http://www.wetswitch.com/
  8. Replies
    32
    Views
    3,431

    So the longer run times in cold weather is what...

    So the longer run times in cold weather is what brings the rads up to temp? You set the flow by delta T(temp rise) through the boiler? Is there a certain starting point with the throttling valve,...
  9. Replies
    8
    Views
    734

    I recently removed 15 lbs of refrigerant from a...

    I recently removed 15 lbs of refrigerant from a heat pump that listed it's factory charge as 5 lb 6 oz. It was shutting off on high head. The maintenace guy from the condo assoc said it ran fine in...
  10. Replies
    32
    Views
    3,431

    How do you explain to the HO when they say the...

    How do you explain to the HO when they say the rads don't get as hot as they used to?
  11. Replies
    32
    Views
    3,431

    http://img222.imageshack.us/img222/774/thecontrols...

    http://img222.imageshack.us/img222/774/thecontrolsow8.jpg
  12. Replies
    32
    Views
    3,431

    [imghttp://img222.imageshack.us/img222/774/thecont...

    [imghttp://img222.imageshack.us/img222/774/thecontrolsow8.jpg/img]
    I don't know if I got this hosting stuff down yet but here's another try. This shows the return piping. I would have to take it all...
  13. Replies
    1
    Views
    446

    When it runs in heat mode it's trying to absorb...

    When it runs in heat mode it's trying to absorb heat from the atmosphere and the pressure in the coil is much lower. Did it used to change speeds or has it always done this? Could be it's supposed to...
  14. Replies
    10
    Views
    915

    What's the venting like? Could be a pressure...

    What's the venting like?
    Could be a pressure switch opening? Can you monitor the draft with the pressure switch jumped out?
    It's a package unit? So it's outside with no chimney? Or just a short...
  15. Replies
    32
    Views
    3,431

    No

    No dielectrics, no.

    I wondered about that draw-off too. The guy who drew up the piping schematic said it was code now. That's what I heard anyway (second-hand). I...
  16. Replies
    32
    Views
    3,431

    I like the Spirovent too but when I started...

    I like the Spirovent too but when I started pumping away I figured I didn't need as effective (or expensive) air elimination. I got cheap, I guess. Not that it's my decision always. Some commercial...
  17. Replies
    32
    Views
    3,431

    So no throttling valves? The bypass pipe the same...

    So no throttling valves? The bypass pipe the same size as the supply and return mains? You'd want to regulate flow somehow, right? I've put bypass loops on boilers before, this one didn't get one...
  18. Replies
    32
    Views
    3,431

    Actually I don't have the manual. Crap! I can...

    Actually I don't have the manual. Crap! I can probably get it though. I wanted to put the bleedin' bypass in and got talked out of it! Now I'm pissed!
  19. Replies
    32
    Views
    3,431

    No it isn't that simple. The circulators are on...

    No it isn't that simple. The circulators are on the supply, pumping away. A bypass would have to be on the discharge side of the circulators for it to work. It said so in the installation manual.
    I...
  20. Replies
    35
    Views
    2,039

    Re: Re: heatinghelp.com

    You're right it doesn't guarantee you won't get butchered but most butchers don't bother to advertise on the internet. That and the professionalism of Dan and the people who hang out there tends to...
  21. Replies
    32
    Views
    3,431

    bypass

    Yup, I know. No bypass. That was the first thing I said when I got to the job. There just wasn't any good way to do it with multiple zones. No excuse, I know. We talked it over and made a conscious...
  22. Replies
    32
    Views
    3,431

    thanks rich

    for fixing that. I tried to delete the whole thing when I couldn't get it to work but I couldn't even do that.
  23. Replies
    32
    Views
    3,431

    Oops!

    Oops!
  24. Replies
    32
    Views
    3,431

    Okay, take your best...

    Okay, take your best shot.[http://img135.imageshack.us/img135/5686/curryaftervu2.jpg]
    [http://img141.imageshack.us/img141/5743/currybeforekw3.jpg]
    Oh, I know, I posted the after before the...
  25. Replies
    29
    Views
    3,635

    circulator

    I hesitate to point this out considering how you seem to feel about criticism but,... isn't that circulator mounted wrong? The instructions say it's ok to go vertical if the motor is on top but...