Search:

Type: Posts; User: mwright

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    22
    Views
    1,236

    I can as long as the outside temp is low enough....

    I can as long as the outside temp is low enough. I can set it so that when the temp is lower than a certain temp the aux heat(oil) will kick in. Other wise the heat pump kicks in. Also have the...
  2. Replies
    22
    Views
    1,236

    I didn't think I would. I know a lot are put in...

    I didn't think I would. I know a lot are put in the fan box. I have my problem solved. Thanks for all the help everyone!!
  3. Replies
    22
    Views
    1,236

    OK I looked at this a little closer. I do have...

    OK I looked at this a little closer. I do have room in the A-Coil box to mount this electric coil. It will fit right above the A-Coil. The only concern I have is moisture when the AC is running in...
  4. Replies
    13
    Views
    3,763

    ECtofix Thanks for the list of things to check....

    ECtofix
    Thanks for the list of things to check. I don't work on these very often so I don't know of "all" the things that can effect these ovens. I'll look into these things.
  5. Replies
    13
    Views
    3,763

    Blodgett DFG1XL/AA

    OK now I have my own mystery. Had a complaint the oven was getting up to temp then they put cold food in and it would drop. Normally it would take a few minutes to come back up but now it's not...
  6. Replies
    22
    Views
    1,236

    Honeywell TB8220U1003 Visionpro 8000 Programmable...

    Honeywell TB8220U1003 Visionpro 8000 Programmable Thermostat
  7. Replies
    22
    Views
    1,236

    It's has snap discs on it. Wasn't thinking about...

    It's has snap discs on it. Wasn't thinking about that for safety over heating. Duhh!!

    As far as baseboard heat, that would defeat the purpose of what I have in place. I'm just looking for a...
  8. Replies
    22
    Views
    1,236

    Supplemental electric heat

    Thanks MontanaJon. I can't mount my strips above the furnace because I got my ACoil then above that I have a UV light so I don't have the room. I'm going to mount them in the plenum right where it...
  9. Replies
    22
    Views
    1,236

    Supplemental electric heat

    I have a oil burning furnace w/ heat pump. I want to add an electric coil to help with the heat pump. I know they design most as a plug in to certain model but I just bought one at random. They are...
  10. Replies
    13
    Views
    1,268

    When it first turns on it fills the holding pan...

    When it first turns on it fills the holding pan with water. The water in the pan is circulated over the evap coils. As the water in the holding pan freezes the water in the pan decreases. It stops to...
  11. Replies
    17
    Views
    2,327

    I use Heritage. Ask for Laura 800-458-5593...

    I use Heritage. Ask for Laura
    800-458-5593
    What kind of pizza oven?
  12. Replies
    30
    Views
    2,597

    Yes I have. The discharge pressure is too high....

    Yes I have. The discharge pressure is too high. There's too much water flow and no matter what I do to the valve it won't adjust. There is a ball valve on the inlet that I have valved almost off to...
  13. Replies
    30
    Views
    2,597

    I know that I can shut the water off and replace...

    I know that I can shut the water off and replace the water
    Pressure valve but what about the pressure side of it, the cap tube, that is brazed into the high side of the system? Are you saying...
  14. Replies
    30
    Views
    2,597

    The pressure regulator is bad. Doesn't matter how...

    The pressure regulator is bad. Doesn't matter how you adjust it it is wide open. So I need to replace it and don't want to evacuate it.
  15. Replies
    30
    Views
    2,597

    Another question on this issue. If the valve is...

    Another question on this issue. If the valve is bad, is there a way I can isolate the refrigerant in the system so I can change it without evacuating the whole system?
  16. Replies
    13
    Views
    3,763

    I think that this unit extinguishes its pilot...

    I think that this unit extinguishes its pilot when the door is opened (if memory serves me). So…you did THAT, which therefore reset the ignition module. You closed the door, it retrialed and worked...
  17. Replies
    30
    Views
    2,597

    When I wasn't high enough I was trying to set it...

    When I wasn't high enough I was trying to set it and no matter where I set it it was tripping out. That's why I was asking at what point in the sequence I needed to set it. Also that's why I'm...
  18. Replies
    30
    Views
    2,597

    It wasn't harvesting. It wasn't getting a high...

    It wasn't harvesting. It wasn't getting a high enough head pressure when the hot gas valve opened, hence not hot enough gas, to break the ice off the evaporator. I was trying to set the water...
  19. Replies
    30
    Views
    2,597

    Ice, Sorry it is water cooled. That's what I'm...

    Ice,

    Sorry it is water cooled. That's what I'm talking about is the regulator that adjusts the water pressure going through the condenser. The amount of water flow adjusts the head pressure. I...
  20. Replies
    30
    Views
    2,597

    Discharge pressure on ice machine?

    According to the maunal on my Scotsman 1356 the discharge pressure should be 245. Now is that all the time or when it going through a freeze or a harvest cycle? I've been trying to adjust it but it...
  21. Replies
    6
    Views
    2,769

    Yeah what model are you working on?

    Yeah what model are you working on?
  22. Replies
    24
    Views
    5,410

    No it does not.

    No it does not.
  23. Replies
    24
    Views
    5,410

    Actually we have a service contract with them. We...

    Actually we have a service contract with them. We pay for all the parts. So they don't care what we spend as long as we fix it. LOL
  24. Replies
    21
    Views
    3,048

    MOD# ICE1406FW2 SER# C420-00298-Z

    MOD# ICE1406FW2
    SER# C420-00298-Z
  25. Replies
    21
    Views
    3,048

    Spoke too soon. Not producing ice again. The...

    Spoke too soon. Not producing ice again. The breaker didn't trip but its not making ice. Any ideas here? Going to check it in the morning but was wondering if anyone had any advice as to what to look...