    Did you guys ever se the episode of Duck Dynasty...

    Did you guys ever se the episode of Duck Dynasty when they had Mountain Man work on the A/C at the shop. ???

    It's about like this video.
  2. Replies
    30
    Views
    2,136

    How about de-rating with smaller orifices ????

    How about de-rating with smaller orifices ????
  3. Replies
    14
    Views
    781

    better check with furnace manufacturer to see how...

    better check with furnace manufacturer to see how much cold air can be brought into unit without damaging heat exchanger. 0 degree air hitting a hot heat exchanger could cause cracking.
    Possibly...
  4. Replies
    21
    Views
    2,647

    This high heat has exposed many dirty condenser...

    This high heat has exposed many dirty condenser coils in my area. Units that can't keep up but once cleaned are running just great.
  5. Replies
    34
    Views
    3,555

    Gotta make hay while the sun shines.

    Gotta make hay while the sun shines.
  6. Replies
    11
    Views
    1,225

    I have used strap on aquastats, hooked up to the...

    I have used strap on aquastats, hooked up to the incoming boiler water pipe. Break the white wire, if thewater temp is above your set point, the call for heat goes to green for fan. If water temp...
  7. If they made a baseboard that would cool, then...

    If they made a baseboard that would cool, then all house flippers would use them.
  8. Replies
    71
    Views
    5,206

    I would be a rich man if i could get people to...

    I would be a rich man if i could get people to replace thier 10 year old systems. Thats just gettin broke in. But, here in michigan, our cooling system is not terribly long. I could maybe see a...
  9. How much heat gain does this place have that he...

    How much heat gain does this place have that he notices it not cooling for couple hours in middle of night.
  10. Replies
    6
    Views
    887

    Maybe start with the flex duct manufacturer??? ...

    Maybe start with the flex duct manufacturer??? They may have the info u r looking for.
  11. Replies
    106
    Views
    7,060

    I think what u were trying to ask was, for...

    I think what u were trying to ask was, for example if u had a pinhole in a solder joint and that hole was plugged with crud or wrapped with insulation or something, the hole could be plugged while...
  12. Replies
    85
    Views
    5,450

    But the thing I hear the most, is actually...

    But the thing I hear the most, is actually silence...... when I ask if the filter is clean.
  13. Replies
    85
    Views
    5,450

    When people call, then ask " what do you think is...

    When people call, then ask " what do you think is wrong with it" like I want to walk them through the operation sequence of the unit.
  14. Replies
    19
    Views
    2,396

    Mobile homes suck, I've seen 3 tons in 1000 sq ft...

    Mobile homes suck, I've seen 3 tons in 1000 sq ft doublewides run nonstop to keep up. That one had a west facing slider door that I think was made from a magnifying glass lol. Anyway, I have no...
  15. Replies
    15
    Views
    1,529

    I pretty sure Bryant/ Payne 40,000, 90% are 14"...

    I pretty sure Bryant/ Payne 40,000, 90% are 14" cabinet width. 12.5" Plenum width.
  16. Replies
    13
    Views
    1,078

    I considered the blower tripping out after time,...

    I considered the blower tripping out after time, but I see no evidence of coil freezing. And homeowner says still blowing good at registers.
  17. Replies
    13
    Views
    1,078

    The TXV systems I install give me a target...

    The TXV systems I install give me a target subcool temp on the label. I will check it when out today tho.
  18. Replies
    13
    Views
    1,078

    Suction line was cold & condensating at the...

    Suction line was cold & condensating at the service valve tho.
  19. Replies
    13
    Views
    1,078

    didnt check SH. Usually dont on TXV system.

    didnt check SH. Usually dont on TXV system.
  20. I think the carrier 100,00 has a 4 ton blower,...

    I think the carrier 100,00 has a 4 ton blower, unless ordered with a 5 ton. I have run into the same situation u r thinking with the right side of N coil being blocked off slightly.
    Took some time,...
  21. Replies
    13
    Views
    1,078

    need some help

    I have been working on a 2 ton trane system, installed in '01, 410a unit, and cant seem to get it right.
    I went out first call, found head press low, suction press low. added freon, couldnt get...
  22. Replies
    14
    Views
    1,116

    Sounds like a " lil Popper" with a voltage...

    Sounds like a " lil Popper" with a voltage readout.
  23. Replies
    8
    Views
    863

    Gotta make hay while the sun shines.

    Gotta make hay while the sun shines.
  24. Replies
    13
    Views
    1,523

    Around here, that would have to be engineered and...

    Around here, that would have to be engineered and stamped to even get a permit. With that occopancy load, you will need a lot of fresh air. Then the correct amount of heat/cooling to overcome the...
  25. Replies
    12
    Views
    939

    Good u got it going. Odd stat pwr is run thru...

    Good u got it going. Odd stat pwr is run thru limits. State powered thru furnace, no battery backup. ??