  1. Replies
    6
    Views
    353

    Lost a compressor on this unit and was looking...

    Lost a compressor on this unit and was looking for added safety.
  2. Replies
    6
    Views
    353

    Delay llsv or contactor

    Wanting to install a delay on walk in cooler condensor. 3 phase unit on a pump down circuit. I am thinkin delay on solenoid? What are you guys doing out there? Thanks!
  3. Replies
    11
    Views
    1,059

    They would be for a little bit of everything....

    They would be for a little bit of everything. Refrigeration, air conditioning, ice makers, deli cases. Are they better for one or the other?
  4. Replies
    11
    Views
    1,059

    Digital guages?

    I know this has been beat to death on here. But what's everyone's opinion on the best digital guages? As of now I'm between testo 557 and sman 3. Thoughts?
  5. Replies
    18
    Views
    1,039

    ^same

    ^same
  6. Replies
    11
    Views
    753

    Had a bad control board. Thanks for the help.

    Had a bad control board. Thanks for the help.
  7. Replies
    11
    Views
    753

    I was wondering about a transformer myself. Was...

    I was wondering about a transformer myself. Was hoping someone would bring it up. It looks like the transformer would be part of the board? This is a pretty new model ,haven't had much experience...
  8. Replies
    11
    Views
    753

    I should add that this fuse is popping pretty...

    I should add that this fuse is popping pretty loud. It sounds like a dead short. It blew one of the fuses half out of its retainer.
  9. Replies
    11
    Views
    753

    It blows the fuse as soon as I switch the breaker...

    It blows the fuse as soon as I switch the breaker on. Went thru three fuses. Started looking for short, can't find anything so far.
  10. Replies
    11
    Views
    753

    Manitowoc IY0894N-261

    This machine is fairly new. Blows fuse on control board. Is there a common problem with this model that anyone is aware of? I have done the common sense stuff (looked for bare wires etc) hard to...
  11. Replies
    3
    Views
    359

    Ice maker water filter

    What are you guys using to keep rust out of ice makers? I am working on an ice o matic model ICE1806HR2. This is at a gas station and on a well. The distribution tubes loaded with a paste like rust....
  12. Replies
    13
    Views
    1,268

    Yes sir. I would also make sure your dump valve...

    Yes sir. I would also make sure your dump valve is working properly. You should be starting with fresh water for every cycle.
  13. Replies
    4
    Views
    377

    16 to 18 minutes don't sound bad to me. I would...

    16 to 18 minutes don't sound bad to me. I would be making sure condensor is clean and condensor fan is working.
  14. Replies
    13
    Views
    1,268

    The slush you are seeing is prolly in the...

    The slush you are seeing is prolly in the distribution tube and blocking flow. I have had luck installing new water filters.
  15. Replies
    16
    Views
    1,542

    I would look at when this unit goes into defrost....

    I would look at when this unit goes into defrost. Try to determine if it is overnite. Could have defrost wires intermitantly shorting out. Just a thought.
  16. Replies
    16
    Views
    1,366

    I have had two trane RTU's and one Goodman RTU...

    I have had two trane RTU's and one Goodman RTU blow their 410A charge just this summer. All brand new units.
  17. Replies
    6
    Views
    555

    Small world! I work for a company that owns...

    Small world! I work for a company that owns multiple gas stations and leased locations. From Eastern Iowa to the illinois wisconsin border down to Galesburg illinois.
  18. Replies
    6
    Views
    555

    I am In Ottawa Illinois. We are about an hour...

    I am In Ottawa Illinois. We are about an hour south of Chicago.
  19. Replies
    34
    Views
    2,031

    I have had several of these newer manitowoc units...

    I have had several of these newer manitowoc units have a single cube hold the bin door open, and the display show the machine is full of ice. I agree with the bridge thickness adjustment , Also I...
  20. Replies
    3
    Views
    466

    It was pretty consistent, I got one good drop out...

    It was pretty consistent, I got one good drop out of 5 try's. The control board was showing curtain closed. which made me think the bin switch was working fine. I changed the bin switch and got 3...
  21. Replies
    3
    Views
    466

    Manitowoc QD0492n

    Got a manitowoc ice maker makes ice fine goes into harvest fine. But about 10 or 15 seconds into harvest the red light goes off and system switches back to make ice. During this time the curtain...
  22. Replies
    6
    Views
    555

    Hello from central illinois

    Just wanted to say hi to everyone. I have been in the business with the same company for 20 years. I found this site about a year ago. I would like to thank everyone ahead of time for sharing they're...