Search:

Type: Posts; User: tom1843

Search: Search took 0.00 seconds.

  1. Replies
    7
    Views
    677

    Upgrades are coming

    I forgot to mention I also have a tar and gravel roof. I have new windows on order to replace leaky old ones. I have plenty of insulation in the roof. Power comapny paid for the insulation. All...
  2. Replies
    7
    Views
    677

    I currently have a home in SE Florida of 1100...

    I currently have a home in SE Florida of 1100 square feet. The tech did a load calc and said it would require about 3-3/4 tons to cool. I currenty have a 3.5 ton unit and it works good so feel the...
  3. Replies
    8
    Views
    1,212

    Looks like Unico??

    Thanks to all for your replies. After reading the posts for a few days I am wondering if Unico is the way to go. It is very expensive and is isn't that efficient. The contractor said he would install...
  4. Replies
    8
    Views
    1,212

    No one ??

    No one????
  5. Replies
    8
    Views
    1,212

    I currently have a Unico system and have added an...

    I currently have a Unico system and have added an addition requiring a larger unit and that it beinstalled in the living space per code.

    I looked at the specs for the Spacepak and I like the way...
  6. Replies
    17
    Views
    2,604

    Thank you all for the information. The unit is...

    Thank you all for the information. The unit is matched and working fine.
  7. Replies
    17
    Views
    2,604

    I did this installation in my own house I...

    I did this installation in my own house I wouldn't do this for a customer. I got rid of the 4 ton unit today. The system has the 3.5 ton condenser. The actual length of the lines are 45-50 feet (I...
  8. Replies
    17
    Views
    2,604

    3.5 it will be.

    I don't want problems. Thanks
  9. Replies
    17
    Views
    2,604

    I will step away from the condensing unit

    Thanks for the reply. One last thing. A local AC tech said it would work if you undercharged and that the long lines would help.

    I will stick with the 3.5.
  10. Replies
    17
    Views
    2,604

    I have a 3.5 ton Unico evaporator and want to use...

    I have a 3.5 ton Unico evaporator and want to use a 4 ton condensor. Is there anything really wrong with doing this.

    I know they should be matched. I happen to have a new unit and would like to...
Results 1 to 10 of 10
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event