    hi guys; I have a cuestion,If I put charcoal...

    hi guys; I have a cuestion,If I put charcoal activated in a AHU I can have problems. I whant to do this because,I have problems with the smoke of some fires in the mountain. the smoke goes to...
  2. Thread: york oil

    by clavej2
    Replies
    7
    Views
    1,228

    your you can find fine and heavy oils.EXAMPLE. In...

    your you can find fine and heavy oils.EXAMPLE. In a screw compressor use "L" oil because is more FINE tha "C" C is more heavy and you need to move that oil a pump oil. In the screw comp it does not...
  3. Thread: THERMISTORS

    by clavej2
    Replies
    11
    Views
    1,213

    HI Guys; in a 100 ton york screw compressor....

    HI Guys; in a 100 ton york screw compressor. When the compressor is off,and you put the meter in ohm to read C to S1 or C to S2 or C to S3 the meter should show the lecture ohm or nothing....
  4. Replies
    4
    Views
    631

    EXCUSE ME----- COOLING COIL

    EXCUSE ME----- COOLING COIL
  5. Replies
    4
    Views
    631

    HI; Friends What you think about the cooling...

    HI; Friends What you think about the cooling coli water,I can drink or not. Desire you opinion thanks
  6. Replies
    6
    Views
    842

    what is the display fault?

    what is the display fault?
  7. Replies
    18
    Views
    1,870

    OF ALL WAY CHECK INSIDE OF THE CONTACTOR MAYBE...

    OF ALL WAY CHECK INSIDE OF THE CONTACTOR MAYBE YOU HAS OTHER PROBLEM THERE CHECK VERY CLOSE.
  8. Thread: QUESTION!!!!!!

    by clavej2
    Replies
    4
    Views
    1,196

    good maintenance; example (take first decivel...

    good maintenance; example (take first decivel noise) example. it marks 20dec-noise the first time. you go the next month and marks 28dec then you put grease slowly to reduce the noise to 20dec...
  9. Thread: delta t

    by clavej2
    Replies
    6
    Views
    1,103

    I talking about cooling coil water/degee...

    I talking about cooling coil water/degee setpoint,example cooling coil is 55deg) and you change to 50 or 60deg the fan and dampers feel changes too? THANKS
  10. Thread: delta t

    by clavej2
    Replies
    6
    Views
    1,103

    hello guys;some one explains me the...

    hello guys;some one explains me the meaning,example if I change a cooling coil setpoint),(the fan motor change too in hz or rpm? I talking about ahu cooling coil set-p (no about return set-point) If...
  11. Replies
    9
    Views
    1,081

    hello friend;if example no has ice in the...

    hello friend;if example no has ice in the freezer, check the damper. Maybe some child closed,put your hand and check too for some paper.
  12. Replies
    2
    Views
    715

    hi friends; OK Iam confused on which is the...

    hi friends; OK Iam confused on which is the funsion of the fresh-air. To control that in l specify. thank,
  13. Replies
    5
    Views
    1,841

    not used pump oil.and (fla 66)

    not used pump oil.and (fla 66)
  14. Replies
    5
    Views
    1,841

    HELLO GUYS; Remember the comp,problem last week....

    HELLO GUYS; Remember the comp,problem last week. OK now york serviceman come the next week to pick-up the comp, OK the comp,has a noise as bearing. OK look at this the comp in this moment has this...
  15. Replies
    10
    Views
    1,858

    more inf, (S.P) (D.P)THE YOU CHANGE THE COMP,THE...

    more inf, (S.P) (D.P)THE YOU CHANGE THE COMP,THE YOU BRAZE ON CAP TUBE (AMP)
  16. Replies
    382
    Views
    21,392

    I LIKE TO GO THERE THE NEXT YEAR, I DONT SPEEK...

    I LIKE TO GO THERE THE NEXT YEAR, I DONT SPEEK TOO MUCH ENGLISH,BUT I TRY. I LIVE IN PUERTO RICO BUT I HAVE A LITTLE BOAT,10 FOOT I BE THERE,WAIT FOR ME; CHAWWW
  17. Replies
    6
    Views
    1,951

    LRA (38.2)7=5.4amp

    LRA (38.2)7=5.4amp
  18. Replies
    20
    Views
    3,378

    hello friend; maybe you has problem between (exp...

    hello friend; maybe you has problem between (exp val, some sensor or board) do a visual check in wires loose by some vibration.
  19. Replies
    20
    Views
    3,378

    hello friend; the valve that you tell me,use or...

    hello friend; the valve that you tell me,use or not use voltage.
  20. Replies
    20
    Views
    3,378

    hello friend; you better be sure,about the ...

    hello friend; you better be sure,about the liq-valve is worlking,(that valve receive volt dc or ac) example 120volt 220volt or 0 to 10volt,dc
  21. Replies
    20
    Views
    3,378

    hello friend; you said the suction be back in 2...

    hello friend; you said the suction be back in 2 min, ok what time take to be in 35psig
  22. Replies
    10
    Views
    1,715

    hello friend; flush the cap-tube, to much liquid.

    hello friend; flush the cap-tube, to much liquid.
  23. Replies
    8
    Views
    5,711

    hello friend ;the you take (low,and high...

    hello friend ;the you take (low,and high pressures,do you do the (efficient prove) to the compressor.
  24. Replies
    8
    Views
    5,711

    hello friend; CODGY has reason put 3n1 start kit...

    hello friend; CODGY has reason put 3n1 start kit and check if the has a fan between compressor for some paper in the fan. clean the condenser too.
  25. Replies
    12
    Views
    1,385

    hello, friend Put the suction pr.11psig in cap...

    hello, friend Put the suction pr.11psig in cap tube) or 31psig in txv system, And them look,and take the superheat and disc-pressure. (this only in a short distance between,comp. and evap. And...