  1. Replies
    32
    Views
    1,999

    I pulled the seal and this is what I found. ...

    I pulled the seal and this is what I found. There appears to be discolouration of the stationary seal face and some possible debris. Also, the brass bushing on the shaft appears to have a build-up....
  2. Replies
    32
    Views
    1,999

    I did not see any pitting on the impeller during...

    I did not see any pitting on the impeller during previous repairs but I will inspect closer to rule it out next during next repair.
  3. Replies
    32
    Views
    1,999

    Is there a way to test for this?

    Is there a way to test for this?
  4. Replies
    32
    Views
    1,999

    piping is vertical as in second row. Thanks...

    piping is vertical as in second row.

    Thanks for your help but my pump is not in the orientation of the last three images.
  5. Replies
    32
    Views
    1,999

    5thRoot,, you are right, the vertical set-up is...

    5thRoot,, you are right, the vertical set-up is permitted, yet the motor is not supported, except by the bolts mounting to the bearing assembly. I do not see in the literature where it states it must...
  6. Replies
    32
    Views
    1,999

    Qwerty,, no, in this application I have not...

    Qwerty,, no, in this application I have not tried the maintenance free pump set-up and don't see the need to go down that road at this point.
  7. Replies
    32
    Views
    1,999

    Not sure why TDS is at this level but I have seen...

    Not sure why TDS is at this level but I have seen the reports from the past and the numbers average under 1000 typically. My understanding is that under 2000 ppm is the target. No signs of corrosion...
  8. Replies
    32
    Views
    1,999

    it is verticle orientation. We have had...

    it is verticle orientation. We have had sportatic failures but this is the only repeated failure.
  9. Replies
    32
    Views
    1,999

    Correction of the pump: The current pump is a...

    Correction of the pump:

    The current pump is a Bell and Gossett LD3 iron body three piece 1/4 HP pump.
  10. Replies
    32
    Views
    1,999

    I seem to recall 38 psi.

    I seem to recall 38 psi.
  11. Replies
    32
    Views
    1,999

    Circ Pump Seal Failures

    I have a building with a that has given me a lot of grief due to repeated circulation pump seal failures.

    I have tried going with different seal types, changing out the seal bearing assembly, the...
  12. Replies
    5
    Views
    731

    Thanks guys but I figured it out today after...

    Thanks guys but I figured it out today after going back with a meter that measures Hz.
    After pre-purge the combustion motor should ramp down to 19 Hz. Regardless of adjustments made to pot on board...
  13. Replies
    5
    Views
    731

    ENG A Make up air ignition

    I have a Engineered air DJ 100-0 with a DJM 3.4 controller that has been giving me problems.

    The problem I am having is during light off the pilot wont light unless I block the venter damper and...
  14. Replies
    0
    Views
    338

    Lennox wire diag needed

    Does anyone have access to a Lennox wire diagram?
    Model: GCC16 060 120 4J
    S/N 5602 G 08158
  15. Replies
    2
    Views
    1,292

    Sorry,,, I was actually looking for the slimzone...

    Sorry,,, I was actually looking for the slimzone Premier Manual.
  16. Replies
    2
    Views
    1,292

    Robertshaw Slimzone Deluxe

    Does anyone have a link to the manual for this system?
  17. Replies
    0
    Views
    382

    Dehumidifier Help

    Anyone have any info or links for a dehimidifyiing air handler going under the name Chinook.

    Model: Phi Beta DH25


    There are two Actuating valves on seperate condenser water outlets....
  18. Replies
    4
    Views
    495

    Pulled the heads off compressor #2 today. It was...

    Pulled the heads off compressor #2 today. It was nasty nasty. Top of pistons were pitted really bad. Copper plating around discharge valve seat. One head had a missing spring plate behind the discus...
  19. Replies
    4
    Views
    495

    The oil was good - no metal flakes. It was darker...

    The oil was good - no metal flakes. It was darker than the other circuit yet that was what I was trying to clean up. It has a history of dark oil on this circuit which is getting better yet still...
  20. Replies
    4
    Views
    495

    35 tone Copland Discharge Valves

    I was changing out the drier cores in a Mcquay Alp 150 and found chunks of valve plate inside the drier shell.

    There are two circuits 75 tons aside.

    Each circuit has two 35 ton coplemetics (6D...
  21. Replies
    14
    Views
    1,309

    ??? Check my contact info then send me an EMAIL....

    ???
    Check my contact info then send me an EMAIL. Then I will send you the PDF file. Try Again.


    By the way unit is operable now. It was the sensor!!
  22. Replies
    14
    Views
    1,309

    Send me an email and I will forward it to you.

    Send me an email and I will forward it to you.
  23. Replies
    14
    Views
    1,309

    I have an issue with this unit occasionally...

    I have an issue with this unit occasionally tripping on low water temp fault. I now know the leaving water temp sensor is a 10,000 ohm thermister and I can check its resistance at a given temp to...
  24. Replies
    14
    Views
    1,309

    Thank You! This will help a lot and is greatly...

    Thank You!

    This will help a lot and is greatly appreciated. Not even my trane supplier could provide this to me.

    You Da Man!
  25. Replies
    14
    Views
    1,309

    Thanks Willf650 . The model is GEHB03032H0120RLC.

    Thanks Willf650 . The model is GEHB03032H0120RLC.