    OP has already replaced induced and getting the...

    OP has already replaced induced and getting the same results.
  2. Replies
    43
    Views
    1,272

    You can cut it and glue a coupling back in place,...

    You can cut it and glue a coupling back in place, or just pull it out of the inducer if that is possible. You not looking to run for 10 - 20 mins. Your troubleshooting by removing variables. This...
  3. Replies
    43
    Views
    1,272

    Just like I worked with a guy who said, "Its a...

    Just like I worked with a guy who said, "Its a factory defect that it doesn't get enough combustion air and therefore not my problem. I "fixed it" by taking out a knockout."
  4. Replies
    43
    Views
    1,272

    If you put in the lower switch without calling...

    If you put in the lower switch without calling the factory to verify altitude reasoning for a lower setting you might as well stamp "Parts Changer" on your forehead!
    Have you tried running the...
  5. Replies
    43
    Views
    1,272

    You should be close to 1" w.c. over rated. Check...

    You should be close to 1" w.c. over rated. Check secondary for restriction. Is this on propane?
  6. Replies
    11
    Views
    317

    I have worked with Jackson zone boards, they are...

    I have worked with Jackson zone boards, they are ok. I prefer Honeywell and never worked on Zone First.
  7. Thread: CO2

    by MontanaJon
    Replies
    23
    Views
    599

    That's the best thing I have seen this year.

    That's the best thing I have seen this year.
  8. Replies
    45
    Views
    1,298

    I was just about to say that. It would be...

    I was just about to say that. It would be strange but maybe it has to have a load to work. To drain it so to speak.
  9. Replies
    18
    Views
    676

    I only use a universal pressure switch to get by...

    I only use a universal pressure switch to get by until I get factory one. But I also don't feildpiece's machine that can pressurize the switch so you can get the correct cut-in. Also I prefer the...
  10. Replies
    45
    Views
    1,298

    2 and 3 are 24 v, hot and common, 2 sends 24 to 1...

    2 and 3 are 24 v, hot and common, 2 sends 24 to 1 so when LPS opens 1 has 24 output to contactor. Wire 1 on outlet of LPS to control board and 2 to hot and 3 to common.
  11. Replies
    45
    Views
    1,298

    That's used to bypass the LPS, it's a delay on...

    That's used to bypass the LPS, it's a delay on break so when you start the compressor and it hits below LPS it still runs. However after your selected time it allows the LPS to operate normally. If...
  12. Replies
    18
    Views
    676

    White Rodgers universal ignitors, honeywell...

    White Rodgers universal ignitors, honeywell ignition modules, rescue motors, turbo 200 and 200x, universal potential relays, 3-n-1 caps for reach ins, etc
  13. Replies
    11
    Views
    399

    Vtp99... I heare ya. Side note, true r/i going...

    Vtp99... I heare ya. Side note, true r/i going propane on new line? Had a college tell me this.
  14. Replies
    11
    Views
    399

    Mediums temp r12 replacement, r416a. Runs lower...

    Mediums temp r12 replacement, r416a. Runs lower discharge and cooler condensor. Also can charge to 100% of name plate. Compatiable with all oils.
  15. Replies
    54
    Views
    3,378

    I also believe the new trap design and z tube are...

    I also believe the new trap design and z tube are an issue. We started only draining out the right and installing a vent on the drain line.
  16. Upright or horizontal? Propane or natural?

    Upright or horizontal? Propane or natural?
  17. Replies
    54
    Views
    3,378

    I put in a MN7 in my house last year before...

    I put in a MN7 in my house last year before Christmas. I have not had single issue and it was negative temps a few weeks ago.
    I have had the water droplet issue on many of the new carrier furnaces....
  18. Replies
    12
    Views
    797

    Looks like head pressure controls (A8L). The...

    Looks like head pressure controls (A8L). The reason I say this is because of the copper tube that is most likely going to the liquid line, so the valve can open and close to the differential it is...
  19. Thread: Travel Pay

    by MontanaJon
    Replies
    19
    Views
    720

    No GPS. Like I said earlier I think I am more...

    No GPS. Like I said earlier I think I am more upset by not being notified that he was going to change his methods.
  20. Replies
    6
    Views
    359

    I don't have the answer for that. But I would...

    I don't have the answer for that. But I would assume they would be the same 10k at 77. Why make two or three boards when one can work in all applications.
  21. Thread: Travel Pay

    by MontanaJon
    Replies
    19
    Views
    720

    Rider. Or bathroom breaks too. Lol. I look at...

    Rider. Or bathroom breaks too. Lol. I look at it the same as you, just trying not to fire off an angry email and really start a storm.

    I have "heard" that if the employer "charges" travel at...
  22. Replies
    6
    Views
    359

    I believe all CXM boards have the same error...

    I believe all CXM boards have the same error codes. Do you know how to retrieve the error code? Your FP1 is for a water only system and FP2 for antifreeze system which can get down to I think 25...
  23. Thread: Travel Pay

    by MontanaJon
    Replies
    19
    Views
    720

    Rider77.. It appeared on any travel. Some jobs...

    Rider77.. It appeared on any travel. Some jobs are 2 hrs away 1 way. I was also posting in town travel. Being the good employee and all. My previous employer paid all the travel even if I was in...
  24. Thread: Travel Pay

    by MontanaJon
    Replies
    19
    Views
    720

    Travel Pay

    Just curious about the way others get paid for travel. My boss recently asked us to separate travel and work time because some customer dispute their bills and he needed help backing up the bill. ...
  25. Replies
    14
    Views
    819

    The E2 says I can set split a few different ways....

    The E2 says I can set split a few different ways. It can control a valve, shut off fans, either odd or even or first half or last half. Without being in front of controller I don't know if I can...
  26. Replies
    14
    Views
    819

    Not a micro channel coil and it is 507, which I...

    Not a micro channel coil and it is 507, which I haven't used yet either.

    I found in the e2 book that I can set it up as a "split" condenser which should allow at least 1 fan on all the time. Like...
  27. Replies
    14
    Views
    819

    Stopped by tonight and borrowed the e2 book. ...

    Stopped by tonight and borrowed the e2 book. Going to read up and try to understand it's logic.
  28. Replies
    69
    Views
    2,212

    Cap tube plugged

    Cap tube plugged
  29. Replies
    14
    Views
    819

    Rack Winter Charging Issue

    Am at a loss and afraid I might be over thinking as well. I have a rack system that was installed in July and not set up for winter, I am not the installer btw they are out of towners. It got down...
  30. Replies
    10
    Views
    278

    Agree with Circus, 62 is too high. Where did you...

    Agree with Circus, 62 is too high. Where did you take suction reading, on liquid line or suction port? Also you are not checking subcooling. Is it fixed orifice outside or txv? Need some more...
  31. Replies
    11
    Views
    590

    If your tripping the "high limit" then what is...

    If your tripping the "high limit" then what is your delta T? Is the filter plugged? Is it the "flame rollout" tripping? Are all the returns and supplies open? Static pressure across furnace?
  32. Replies
    20
    Views
    3,228

    About 6 months ago the porlan guy came by and was...

    About 6 months ago the porlan guy came by and was talking about these.

    http://sporlanonline.com/smart/
  33. Replies
    2
    Views
    452

    Zone 1 works fine on its own, when I was there...

    Zone 1 works fine on its own, when I was there testing. No power drop that I saw. Did not duplicate error because of customer pushing me out the door @ 5.

    I will be heading back tomorrow.
  34. Replies
    2
    Views
    452

    honeywell zone controls

    I have a honeywell truezone and 1 add-a-zone panel for an office. They are using 6 zones. The customer complains about the lobby (zone 1) not staying a consistent temp. All zone set the same...
  35. Replies
    22
    Views
    1,494

    All heat strips are mounted above the evap...

    All heat strips are mounted above the evap coil...I don't think u will have any issues.
  36. Replies
    14
    Views
    1,309

    Where is the ignitor in relation to the burners?

    Where is the ignitor in relation to the burners?
  37. Replies
    14
    Views
    1,309

    Did you tey wideing the crossover or swapping...

    Did you tey wideing the crossover or swapping burners around? I take it you looked at the orifice. Try pulling the manifold off and see if there is debris?

    Did you get the burner to ignite...
  38. Replies
    24
    Views
    2,017

    I like to be a tech, make me feel good fixing...

    I like to be a tech, make me feel good fixing things. I don't push on sales just try to educate customer about better systems. At the company I work for we give the leads to a salesman and they go...
  39. Replies
    22
    Views
    1,494

    I worked an oil furnace with electric heat strips...

    I worked an oil furnace with electric heat strips and the customer had the electric heat strips mounted in the supply over the furnace. Where he lived the electric rate was cheaper than oil...had a...
  40. Replies
    10
    Views
    893

    Install a taco zone valve after the coil, the...

    Install a taco zone valve after the coil, the taco is orange not green power head. Then on the inlet of the coil install a gate valve and a sight glass flow meter, something that tells you gpm. ...
  41. Replies
    140
    Views
    10,626

    How many shut the pump off while it is in a...

    How many shut the pump off while it is in a vacuum? They say of you do you could seize the vains and need a new pump.
  42. Replies
    9
    Views
    826

    Don't forget to make sure a bleed resistor is on...

    Don't forget to make sure a bleed resistor is on the start cap.
  43. Replies
    9
    Views
    826

    Relay

    Relay
  44. Thread: Aspen 416

    by MontanaJon
    Replies
    10
    Views
    1,361

    I use 416 on all my r12 conversions at med temp. ...

    I use 416 on all my r12 conversions at med temp. Dont have to derate 20% of charge. Also look it in reach ins, do have afew larger systems (10+#'s) and they work just fine. 416a is not designed...
  45. Thread: gauges

    by MontanaJon
    Replies
    26
    Views
    2,577

    I have 4 sets of gauges and just ordered an...

    I have 4 sets of gauges and just ordered an ak-900, really curious if I will like them. Now one of mine are stubies for ice machines andreach-ins. And my old 3 port for checking oil...
  46. Thread: rant

    by MontanaJon
    Replies
    8
    Views
    739

    Omg...r u f*n serious....I was at the parts house...

    Omg...r u f*n serious....I was at the parts house and this guys aske me, "how the hell do u fix one of those Carrier pick-n-hold furnaces". I laughed and said, "you find a crack in the heqt...
  47. Thread: Beer cooler

    by MontanaJon
    Replies
    3
    Views
    440

    Lol...so I was there at 10pm to 1230am and today...

    Lol...so I was there at 10pm to 1230am and today I walked around and found another cooler with freezer inside...hmmm..only one low temp and med temp condensor outside. Cases ran together in...
  48. Thread: Beer cooler

    by MontanaJon
    Replies
    3
    Views
    440

    Oh yea ran 40 yesterday.

    Oh yea ran 40 yesterday.
  49. Thread: Beer cooler

    by MontanaJon
    Replies
    3
    Views
    440

    Beer cooler

    Customer called me friday night coolcooler above 50. Arrived on site unit cycling on hp switch. One condensor fan down. Replacedfan and ran system. Pumped down system and poping hp switch. ...
  50. Put in water cooled condensor...lol

    Put in water cooled condensor...lol
Results 1 to 50 of 105
Page 1 of 3 1 2 3

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine