03-02-2005, 02:40 PM
Thread: Another discussion
by stef- Replies
- 6
- Views
- 727
I also post this post in the Residential. I kinda...
I also post this post in the Residential. I kinda think it is interesting to get feed back from you guys.
Filtering the dirt in the air using water. If we use our chilled water spraying and have... -
03-02-2005, 02:27 PM
Thread: electrostatic filters
by stef- Replies
- 55
- Views
- 5,074
How about this dirt trapping system. We treat...
How about this dirt trapping system.
We treat the water say like the chiller does. Spray the water and let our return air pass through it. Pretent the air is like a car passing through the car... -
03-02-2005, 01:45 PM
- Replies
- 6
- Views
- 1,751
Please find out, then let us help you.
Please find out, then let us help you.
-
03-02-2005, 12:24 PM
Thread: totaline cg1000
by stef- Replies
- 1
- Views
- 734
EAC the best if properly install, maintain, and...
EAC the best if properly install, maintain, and usage.
-
03-02-2005, 12:14 PM
- Replies
- 6
- Views
- 1,751
You should not have any problem with burning...
You should not have any problem with burning candles for your enjoyment. It is not like you just started it.
I recommend you to use 4 inches pleated filter to catch the soot a litle better. This... -
Miller2000, Let's go over all info you gave...
Miller2000,
Let's go over all info you gave us.
You have a heat pump?
What size (ton) unit is it?
The piston you pull is from the indoor or ourdoor unit? -
03-02-2005, 11:32 AM
- Replies
- 5
- Views
- 1,829
Dear cbkiteflyer, Keep your old unit, replace...
Dear cbkiteflyer,
Keep your old unit, replace the discharge temp sensor. If I am not correct, HS22 is the 12 SSER system.
Don't let the unknowledgeable tech, who came to your house, scare you.... -
03-02-2005, 11:10 AM
- Replies
- 17
- Views
- 1,382
Baldloonie, You are right on some HW...
Baldloonie,
You are right on some HW thermostat. But here he has a Chronotherm IV, which does not apply with your reasoning. -
03-02-2005, 11:07 AM
Thread: Using a larger condenser than called for?
by stef- Replies
- 17
- Views
- 1,959
Tom1843, It is best of course to install TXV in...
Tom1843,
It is best of course to install TXV in any system. Especially your mismatch sytem.
Migration of freon during the off cycle. Especially the fix flow rater type metering device. Freon will... -
03-02-2005, 09:49 AM
- Replies
- 17
- Views
- 1,382
Hey Beltbuckle, The answere is NO and Yes. ...
Hey Beltbuckle,
The answere is NO and Yes.
NO - because the Y (compressor) terminal will be energized on BOTH heat call and Cool call.
Yes - Unless you do ONE of the following:
Option 1:... -
Miller2000, I don't mean to be rude. If you...
Miller2000,
I don't mean to be rude. If you don't mind, tell us where exactly you put your gauge to read these number?
Have fun -
03-01-2005, 09:33 AM
Thread: Using a larger condenser than called for?
by stef- Replies
- 17
- Views
- 1,959
If you do this yourself for your own house, then...
If you do this yourself for your own house, then I say go for it. 4 tons outdoor with 3.5 tons indoor - NO Problem if you at least put in an expansion valve. As for 78 feet of freon line, my...
-
02-28-2005, 06:06 PM
Thread: freon converting
by stef- Replies
- 16
- Views
- 1,805
Dear hnil, I hope that you have worked on this...
Dear hnil,
I hope that you have worked on this compressor before and familiar with the components of this compressor.
As told by westcoast, It will not be an easy task. And no R22 will not... -
02-28-2005, 05:33 PM
Thread: help in undersanding energy efficient issues
by stef- Replies
- 60
- Views
- 3,334
Don't let the SEER fool you. don't forget to...
Don't let the SEER fool you. don't forget to consider your region of living.
Example: If you are living in Minisota, It is not wise to choose a very high SEER comparing to a guy like me living... -
SEER
SEER is of course stands for SEASONAL ENERGY EFFICIENCY RATING.
The simplest (but not an only formula ARI used) formula for SEER is:
Winter days usage
SEER = 1.2 x... -
02-26-2005, 11:28 AM
- Replies
- 2
- Views
- 688
contact your lennox dealer and ask for the...
contact your lennox dealer and ask for the conversion kit, which includes orifices, and springs.
Springs are to bereplaced for your gas valve since propane has higher pressure
Orifices, which... -
02-26-2005, 10:23 AM
Thread: Lennox 80 UHG
by stef- Replies
- 23
- Views
- 3,484
PARTS CHANGER. Since you are good at replacing...
PARTS CHANGER. Since you are good at replacing part after part. Might as well keep going to other part. Give us a step by step of problem you encounter so we can help man
-
02-26-2005, 09:56 AM
Thread: ohming out compressor
by stef- Replies
- 7
- Views
- 5,314
C and R - Lowest C and S - Low S and R -...
C and R - Lowest
C and S - Low
S and R - Highest and MUST be equal to the sum of the resistenace of C & R plus C & S -
02-25-2005, 03:12 PM
- Replies
- 12
- Views
- 2,332
If you want to call them burner, then I use that...
If you want to call them burner, then I use that same term.
Look at how they are close to each other. The burner is designed round and flat on each end. If you look at each one of them closely.
... -
02-24-2005, 03:00 PM
Thread: Trane gas furnace help, Keeps relighting
by stef- Replies
- 9
- Views
- 1,815
Steph, Too much information, no DIY, see forum...
Steph,
Too much information, no DIY, see forum rules.
Bob
ALL of this mus be done by a qualify technician. Please don't fix the heater by your self. -
02-24-2005, 02:43 PM
Thread: Trane high kwh usage
by stef- Replies
- 56
- Views
- 5,469
quote:...
quote:
--------------------------------------------------------------------------------
Originally posted by stef
High humidity out side has nothing to do with the service. ... -
02-24-2005, 02:28 PM
Thread: MP39 or 409a??
by stef- Replies
- 25
- Views
- 8,967
Dear Icehouse, Indeed R22 is used in low temp...
Dear Icehouse,
Indeed R22 is used in low temp application and I and no one else deny that. All I said is that R22 is not a friendly type of freon to use on low temp comparable to othe brand such... -
02-24-2005, 11:23 AM
Thread: single vrs 2 stage
by stef- Replies
- 7
- Views
- 838
The house has a lennox for 40 years, that serves...
The house has a lennox for 40 years, that serves him and previous owner well. Do you think he goes with other brand????
My question to Doc and IRA:
Wehave a complete match system. But whitout... -
02-24-2005, 11:03 AM
- Replies
- 19
- Views
- 1,870
It is best to have a qualified service technician...
It is best to have a qualified service technician out to check your heating system.
I always train my technician that "when you make a mistake with an air condition repair, you can go back and fix... -
02-24-2005, 10:59 AM
Thread: Trane high kwh usage
by stef- Replies
- 56
- Views
- 5,469
Dear sir, I hope you get this message before...
Dear sir,
I hope you get this message before the repair. Once again, remove all old charge. PULL DEEP VACUUM AT LEAST 500 MICRONS. and weight in the BRAND NEW freon. You are good to go on the...
Results 1 to 25 of 38