04-17-2012, 09:33 PM
Thread: manitowoc q454
by electricblue- Replies
- 19
- Views
- 1,157
Very happy to reply. After a cleaning. It seems...
Very happy to reply. After a cleaning. It seems to have fixed it self. Not sure how. Even after the cleaning when the bin would close it took 1.5 mins. after drop to go back to freeze. Now 1.5...
-
04-16-2012, 09:08 PM
Thread: manitowoc q454
by electricblue- Replies
- 19
- Views
- 1,157
Harvest is too long. Cleaned. Ice drops at 1.5....
Harvest is too long. Cleaned. Ice drops at 1.5. Doesn't go back to freeze till around 3.4. Is that right?
-
04-15-2012, 05:08 PM
Thread: manitowoc q454
by electricblue- Replies
- 19
- Views
- 1,157
Thanks surenuff... How is one ever to learn at...
Thanks surenuff... How is one ever to learn at anything with out asking ?'s . Ok, at this point it's an over harvest code. (2 blinks). Now just trying to run down the cause.
-
04-14-2012, 10:30 PM
Thread: manitowoc q454
by electricblue- Replies
- 19
- Views
- 1,157
?
?
-
04-14-2012, 06:28 PM
Thread: manitowoc q454
by electricblue- Replies
- 19
- Views
- 1,157
manitowoc q454
New problem. When I leave I come back machine is off. Open cover harvest light is blinking and no water in tray. So, I reset. I stand around for 3 cycles so far. Done this 3 times so far. Every...
-
04-12-2012, 07:13 PM
Thread: Fill valve not energizing
by electricblue- Replies
- 4
- Views
- 675
OK. I got it. It's the fill valve. When I bench...
OK. I got it. It's the fill valve. When I bench tested, I couldn't blow air through it. Watching start up voltage I can see it supposed to open on voltage applied. When 120 drops out it still...
-
04-12-2012, 06:37 PM
Thread: Fill valve not energizing
by electricblue- Replies
- 4
- Views
- 675
Normally open. Closes on power applied. Bench...
Normally open. Closes on power applied. Bench tested solenoid. It works.
-
04-12-2012, 05:13 PM
Thread: Fill valve not energizing
by electricblue- Replies
- 4
- Views
- 675
Fill valve not energizing
Manitowic q454. The fill valve is not energizing. It just keeps filling with water. The sensor works, light comes on and goes off with level. Any ideas?
-
01-23-2012, 08:41 AM
Thread: Themostat/dehumid ?
by electricblue- Replies
- 8
- Views
- 446
Thanks for your reply
Thanks for your reply
-
01-22-2012, 10:22 PM
Thread: Themostat/dehumid ?
by electricblue- Replies
- 8
- Views
- 446
btt
btt
-
01-22-2012, 10:15 PM
Thread: Themostat/dehumid ?
by electricblue- Replies
- 8
- Views
- 446
Does it benefit to have the outdoor sensor? My...
Does it benefit to have the outdoor sensor? My HP is single stage ssz14
-
01-21-2012, 11:01 PM
Thread: Themostat/dehumid ?
by electricblue- Replies
- 8
- Views
- 446
Themostat/dehumid ?
Can you guys recommend a good stat with dehumid? Got a new Goodman AVPTC variable with a single stage 14 seer HP. I'm in Florida with heavy humidity. I was looking at the Visionpro. But which...
-
01-15-2012, 08:32 PM
Thread: new Goodman install ?
by electricblue- Replies
- 10
- Views
- 490
Looks like defrost winding...
Looks like defrost winding...
-
01-15-2012, 08:09 PM
Thread: new Goodman install ?
by electricblue- Replies
- 10
- Views
- 490
Understand... I'll call Goodman
Understand... I'll call Goodman
-
01-15-2012, 08:03 PM
Thread: new Goodman install ?
by electricblue- Replies
- 10
- Views
- 490
You're killing me.... I'd rather post on a...
You're killing me.... I'd rather post on a message board and get the easy answer. These message boards rock..
-
01-15-2012, 07:56 PM
Thread: new Goodman install ?
by electricblue- Replies
- 10
- Views
- 490
That's not a nice reply..... I'm a sparky here. ...
That's not a nice reply..... I'm a sparky here. Cut me some slack. Don't want to bother my buddy for this. He is really busy.
-
01-15-2012, 07:40 PM
Thread: new Goodman install ?
by electricblue- Replies
- 10
- Views
- 490
new Goodman install ?
I bought a Goodman avptc variable speed AH and a single stage ssz14 heatpump. I noticed when it ramps down the condenser fan runs slow for a bit. Is this right? or ok?
-
10-12-2011, 09:30 PM
Thread: run time of current system
by electricblue- Replies
- 6
- Views
- 373
run time of current system
Manual J says I need a 2.5 ton. I currently have 4 ton. Is there a way to time the cycle of my current system with a set point and outside temp to tell if I am currently over sized?
-
10-10-2011, 08:03 PM
Thread: System size
by electricblue- Replies
- 3
- Views
- 246
75/91 70/40
75/91 70/40
-
10-10-2011, 07:52 PM
Thread: System size
by electricblue- Replies
- 3
- Views
- 246
System size
I did a manual J for my home and it calls for 2.5 ton. I currently have 4 tons. I talked with one of the HVAC contractors that I work with from time to time and he said definitely 4 ton over the...
-
09-14-2011, 08:37 PM
Thread: square duct size?
by electricblue- Replies
- 14
- Views
- 682
:cheers:
:cheers:
-
09-14-2011, 05:34 PM
Thread: square duct size?
by electricblue- Replies
- 14
- Views
- 682
I am doing the the d work. I'm an electrical...
I am doing the the d work. I'm an electrical contractor. I work with a/c guys all the time. I've asked one that I work with alot if he can charge my lineset and exac my old one. I'm just doing...
-
09-14-2011, 12:29 PM
Thread: square duct size?
by electricblue- Replies
- 14
- Views
- 682
Any reason you wouldn't do 24x16? 24 being the...
Any reason you wouldn't do 24x16? 24 being the depth of the unit.
-
09-14-2011, 11:01 AM
Thread: square duct size?
by electricblue- Replies
- 14
- Views
- 682
How hard is it to do a tight install? I could...
How hard is it to do a tight install? I could build a closet...Why not just do a good job at sealing up the db?
-
09-14-2011, 09:00 AM
Thread: square duct size?
by electricblue- Replies
- 14
- Views
- 682
1 Just the plenum 2 Idn 3 I think ahu in attic...
1 Just the plenum
2 Idn
3 I think ahu in attic sucks. Florida building code now requires carbon monoxide detectors if there is an attached garage. (good thing)
4 Idn