01-03-2009, 10:02 PM
Thread: Buderus GC124 aquastat
by masstech- Replies
- 0
- Views
- 531
Buderus GC124 aquastat
I recently installed my first buderus GC124 gas boiler. The aquastat is a honeywell L7148F. This aquastat doesn't have a low limit. I realize that this boiler is a cold start but wouldn't it make...
-
12-30-2008, 09:09 AM
- Replies
- 4
- Views
- 571
Grundfoss
One is a single speed which came with the boiler and the other is the 3 speed. I'm not sure which one is on the mono system. I have the speed set to "2" on the variable speed circ.
-
12-29-2008, 04:22 PM
- Replies
- 4
- Views
- 571
Changed circs.
I did replace the circulators with new Grundfoss circs. with built-in flow check
-
12-23-2008, 03:13 PM
- Replies
- 4
- Views
- 571
Venturi System Combined with Conventional System
I recently did an oil to gas conversion boiler changeout. The existing piping is as follows. Boiler is heating first floor only (1200 ft/2). 2 zones because addition had been done a few years...
-
12-18-2008, 01:10 PM
Thread: T-stat issue
by masstech- Replies
- 2
- Views
- 390
T-stat issue
I recently went to a call which the homeowner said that the furnace wasn't running long enough to satisfy the t-stat. I tested all safety controls and gas valve. Everything tested ok. At first,...
-
12-18-2008, 08:59 AM
Thread: Gas pipe inspection
by masstech- Replies
- 5
- Views
- 945
Gas pipe inspection
I recently did a boiler installation, conversion from oil to gas. The home had previously had gas but hadn't been used for quite some time. When I had the plumber come in to run the new gas lines...
-
12-18-2008, 08:48 AM
Thread: New England Ice Storm 2008
by masstech- Replies
- 6
- Views
- 465
New England Ice Storm 2008
It's amazing what homeowners will do to there heating systems trying to hook up to a generator when the power goes out. I'd like to hear some stories if anyone has any.
-
11-20-2008, 01:09 PM
Thread: Rheem Plus90 IFC circuit board
by masstech- Replies
- 6
- Views
- 1,535
pro forum
Thanks Baldloonie
-
11-19-2008, 12:31 PM
Thread: Rheem Plus90 IFC circuit board
by masstech- Replies
- 6
- Views
- 1,535
Pro membership
Hi Baldloonie,
I've been posting regularly in HVACTalk for 3+ years. I didn't realize that I was posting in the wrong forum. I've never been asked to apply for pro membership before. What does... -
11-19-2008, 12:21 PM
Thread: Rheem Plus90 IFC circuit board
by masstech- Replies
- 6
- Views
- 1,535
-
11-19-2008, 06:02 AM
Thread: Rheem Plus90 IFC circuit board
by masstech- Replies
- 6
- Views
- 1,535
Rheem Plus90 IFC circuit board
Anyone have experience with a Rheem plus 90 upright furnace with an IFC (integrated furnace control) board? The unit is 10 yrs. old. On a call for heat the inducer fan and pre-purge go thru they're...
-
02-11-2008, 07:49 AM
Thread: Adding zone controls to my rheem 90+
by masstech- Replies
- 4
- Views
- 428
Do you mean modular? No it isn't
Do you mean modular? No it isn't
-
02-09-2008, 09:15 PM
Thread: Adding zone controls to my rheem 90+
by masstech- Replies
- 4
- Views
- 428
Adding zone controls to my rheem 90+
I have a 2000ft/2 ranch witha Rheem 90+ (105k input/97k output) forced air system. I'd like to finish part of my basement, roughly 13x26 (338 ft/2) and add heat by tapping off of my existing supply...
-
10-16-2007, 07:31 PM
Thread: Buderus/Carlin issues
by masstech- Replies
- 4
- Views
- 780
Buderus/Carlin issues
I have a buderus boiler with carlin burner. It was installed two years ago. During summertime use (indirect water heater) it runs fine. The problem is when the colder weather begins. It fires up...
-
09-19-2005, 07:47 PM
Thread: Hi-Velocity System
by masstech- Replies
- 1
- Views
- 671
Hi everyone! I'm new at installing Energy Saver...
Hi everyone!
I'm new at installing Energy Saver Hi-Velocity Systems. Why does the manufacturer insist on putting the access ports & sightglass at the evaporator end of the system. I'm use to seeing... -
08-15-2005, 06:28 PM
Thread: compressor froze up
by masstech- Replies
- 7
- Views
- 802
Carrier 5 ton with scroll compressor. Suctionline...
Carrier 5 ton with scroll compressor. Suctionline pressure was 40 PSI, Liquid Line Pressure was 200 PSI. Superheat 4 deg. Subcool 2 deg.
-
08-15-2005, 09:37 AM
Thread: compressor froze up
by masstech- Replies
- 7
- Views
- 802
We recently did a service call for a local club...
We recently did a service call for a local club in our area.The call was for not enough cold air coming from the vents. We put our gauges on the system and they had no superheat or subcooling. We...
-
08-14-2005, 08:52 PM
Thread: Taco Zone Relay
by masstech- Replies
- 1
- Views
- 1,140
My question concerns using a Taco 1 zone...
My question concerns using a Taco 1 zone switching relay with a 8148 control on a 2 zone heating system. Is it possible to use these two controls together? It seems like when the zone that is being...
-
06-28-2005, 07:30 AM
Thread: Overhead Oil line
by masstech- Replies
- 10
- Views
- 1,105
My question for the day is why do you not see...
My question for the day is why do you not see more oil lines run overhead as opposed to being buried in concrete? Seems to me it would be easier and cheaper time wise to do it this way.
-
05-11-2005, 09:55 AM
Thread: Drip Leg's on gas furnaces
by masstech- Replies
- 13
- Views
- 1,653
This is for the H/O who asked what the drip leg...
This is for the H/O who asked what the drip leg is for. It's to keep any rocks, limbs, and Sunamis that may find their way to your appliance.
-
05-11-2005, 09:39 AM
Thread: Adding Steam Radiator
by masstech- Replies
- 4
- Views
- 788
I recently got a call from a customer who wants...
I recently got a call from a customer who wants to add an additional radiator to the 3rd floor of his home. The only way to do this in his situation is to tee off the 2nd floor radiator directly...
-
03-21-2005, 07:11 PM
Thread: Tankless with a super-stor
by masstech- Replies
- 12
- Views
- 1,838
Thanks for your imput. My initial feeling was to...
Thanks for your imput. My initial feeling was to go with the indirect.
-
03-21-2005, 08:06 AM
Thread: Tankless with a super-stor
by masstech- Replies
- 12
- Views
- 1,838
I'm currently quoting a boiler for a community...
I'm currently quoting a boiler for a community development block grant and the spec calls for a boiler with a tankless coil and a 30 gal. super-stor on the side. Is there a real cost savings or...
-
03-03-2005, 06:05 AM
Thread: oil tank code
by masstech- Replies
- 3
- Views
- 811
Does anybody know the state code for...
Does anybody know the state code for Massachusetts concerning oil tanks? Someone at FW Webb said that tanks with the oil line coming from the side of the tank is illegal in Mass, it has to be coming...
-
02-01-2005, 06:43 AM
Thread: Mixing valve
by masstech- Replies
- 6
- Views
- 1,213
I recently received a call from a customer...
I recently received a call from a customer complaining of having no mixing valve on her tankless coil. What I found was two boilers in this home with one having a mixing valve and the other piped...