Search:
Type: Posts; User: cobradb
Search: Search took 0.01 seconds.
-
11-04-2011, 09:46 PM
Thread: trane question
by cobradb- Replies
- 9
- Views
- 642
thanks for the reply's the new house builder...
thanks for the reply's
the new house builder got it fixed and told us that the thermostat was for a gas pack unit vs HP and a lot of other made up crap. -
11-02-2011, 08:48 PM
Thread: heat pump Temp rise vs SEER
by cobradb- Replies
- 3
- Views
- 309
yes i kn, but that doesnt ans my question
yes i kn, but that doesnt ans my question
-
11-02-2011, 08:17 PM
Thread: heat pump Temp rise vs SEER
by cobradb- Replies
- 3
- Views
- 309
heat pump Temp rise vs SEER
anyone have access to a chart that shows; (heat mode)
Temp rise VS SEER numbers -
10-22-2011, 08:01 PM
Thread: Heat pump and strip heat questions
by cobradb- Replies
- 28
- Views
- 2,143
Like Gross said for ex my house is well...
Like Gross said
for ex my house is well insulated and tight,, i feel comfortable without aux heat until 12 deg or so,,(and my rheam produces high 70's temp at that oat)
i have added a sw on my... -
10-18-2011, 02:21 PM
Thread: Obama's union bribes
by cobradb- Replies
- 2
- Views
- 3,079
every leader in washington needs to understand...
every leader in washington needs to understand what it takes to make a payroll week after week before getting elected.
-
10-17-2011, 08:30 PM
Thread: trane question
by cobradb- Replies
- 9
- Views
- 642
trane question
new trane 2.5 ton heat pump
a friend as me to look at a new house they were to buy,,walked in (oat 80 deg) and the house was so hot we could not breathe,, thermo said cool but it was heating and i... -
09-03-2011, 10:42 PM
Thread: york split question,subcool response
by cobradb- Replies
- 4
- Views
- 452
should have said liquid line temp and saturation...
should have said liquid line temp and saturation temp abt the same. 105
-
09-03-2011, 08:35 PM
Thread: york split question,subcool response
by cobradb- Replies
- 4
- Views
- 452
york split question,subcool response
2ton 15 yr old york split HP; txv; accumulator
cooling look good but i decided to check my unit white the september heat was hot.
Out amb 95, humidity 40
press; 77, 225
saturation temp 105 ... -
06-30-2011, 05:01 PM
Thread: Is an attic vent fan beneficial?
by cobradb- Replies
- 20
- Views
- 1,863
I sat thru a dept of energy program on attic...
I sat thru a dept of energy program on attic ventilation,, some i agreed with and some i didnt
anyway they have data (and i dont have my hands on it now) that shows moisture is more important than... -
06-05-2011, 08:52 PM
Thread: Goodman stuck in Defrost
by cobradb- Replies
- 21
- Views
- 683
dont feel rejected,, it makes some feel better...
dont feel rejected,, it makes some feel better when they can vent,,, but the rules are there for a reason,,, i give you an A for effort.
-
06-05-2011, 11:05 AM
Thread: Problem diagnosing Heat pump
by cobradb- Replies
- 17
- Views
- 2,261
not trying to be a smart ass but --if i were a...
not trying to be a smart ass but --if i were a home owner and saw this diagnostic trail i would ask if i needed a new comp?
-
04-17-2011, 10:54 AM
Thread: Mitsubishi City Multi
by cobradb- Replies
- 48
- Views
- 16,337
what is cost vs PTAC,,,20% more?
what is cost vs PTAC,,,20% more?
-
02-25-2011, 06:48 PM
Thread: Heat pumps
by cobradb- Replies
- 30
- Views
- 2,161
never understood why people dont let the pump and...
never understood why people dont let the pump and thermostat work,, my 13 seer balance point is about 12 deg F, then it runs all the time,, but my house is well insulated and sealed by me. AT 12-15 f...
-
02-12-2011, 09:09 AM
Thread: Heat Pump Charging in the Winter
by cobradb- Replies
- 15
- Views
- 5,485
charging charts, experience, a little common sense
charging charts, experience, a little common sense
-
02-10-2011, 10:17 AM
Thread: Flame sensors
by cobradb- Replies
- 28
- Views
- 1,776
Flame sensors
as i understand it- most flame sensors use the flame to send a signal to ground for the board to process the sequence.
is this signal a DC pulse produced from the flame?
thanks -
02-10-2011, 08:58 AM
- Replies
- 2
- Views
- 1,053
propane (LP) produces (H20) water during...
propane (LP) produces (H20) water during combustion, hopefully most is vented out,, dont kn the gas u are using
-
02-04-2011, 08:10 PM
Thread: coil corrosion protection
by cobradb- Replies
- 0
- Views
- 283
coil corrosion protection
what are the exp and opinions on using chem on evaporators for corr protection? Any sig efficiency change?
thanks
db -
02-02-2011, 05:39 PM
Thread: our leaders
by cobradb- Replies
- 1
- Views
- 266
our leaders
When i heard on the new about congress talking about their pay i thought of this
one of our founding fathers said
" when people find they can vote themselves money it will herald the end of the... -
01-31-2011, 09:02 PM
- Replies
- 176
- Views
- 5,512
rumor has it that Elvis has obama's B Certificate
rumor has it that Elvis has obama's B Certificate
-
01-21-2011, 10:07 PM
Thread: Filter selection
by cobradb- Replies
- 10
- Views
- 849
Filters
have done some building i can tell you that one of the big mistakes is cutting the filter opening too small and then have the owner put in a closed/tight filter.
as stated before on here this is... -
01-21-2011, 09:40 AM
Thread: Rheem delta t
by cobradb- Replies
- 0
- Views
- 228
Rheem delta t
Calling Rheem meisters
does any one know the delta t (ambient vs coil temp) for Rheem.
3 ton 13 seer R22 package 72f indoor
i have changed defrost board (seems to work fine until hi... -
01-10-2011, 09:52 AM
Thread: Disable aux heat?
by cobradb- Replies
- 22
- Views
- 3,608
jfx see the pict,, if you kn what you're doing...
jfx
see the pict,, if you kn what you're doing you can add a sw in series with the aux wire,, assuming the control board controls the aux heat during defrost.. and you sw it to aux when it gets ...... -
01-08-2011, 10:44 AM
Thread: 1 or 2 filters?
by cobradb- Replies
- 11
- Views
- 624
if you dont have anyway to measure air...
if you dont have anyway to measure air flow,,comparing filters this is what i would do
for years i have used the cheap see thru filters and sprayed with end dust,, spray couple of times,,i do have... -
01-06-2011, 04:41 PM
Thread: One brand over another..
by cobradb- Replies
- 13
- Views
- 801
Like Ball said plus they all have cost...
Like Ball said
plus they all have cost reductions and process changes along the way that can effect quality -
01-05-2011, 09:08 PM
Thread: Min intake temp recommedation
by cobradb- Replies
- 5
- Views
- 287
thanks to all who responded this unit is for...
thanks to all who responded
this unit is for the upstairs which is not occupied and has been set at 63. yes my old school books stated 65 is the min for heat pump intake,, but that book is 15 yrs...
Results 1 to 25 of 52