  1. Replies
    20
    Views
    1,172

    Problem solved! Internal filter drier was...

    Problem solved!

    Internal filter drier was restricting flow. You know the ones i'm talking about, those POS copper FD's that trane put inside the unit. The mesh had actually come apart and the...
  2. Replies
    57
    Views
    2,398

    tech rep or salesman...?

    tech rep or salesman...?
  3. Replies
    57
    Views
    2,398

    I wouldnt hold it against him, he doesn't NEED to...

    I wouldnt hold it against him, he doesn't NEED to know, and is confused.

    Truth is, i didnt even know until earlier today...
  4. Replies
    57
    Views
    2,398

    If you read the article i posted, it would be...

    If you read the article i posted, it would be more aptly named a "rectified current sensor".
  5. Replies
    57
    Views
    2,398

    http://www.wardburner.com/flamerectification.html

    http://www.wardburner.com/flamerectification.html
  6. Replies
    27
    Views
    1,969

    actually, they just gave me a new 3/8" ratchet,...

    actually, they just gave me a new 3/8" ratchet, no questions asked.

    but i did have one question "can i keep the broken ratchet?" ... "no."

    "but it has sentimental value..."
  7. Replies
    18
    Views
    1,662

    i have two sets of brute II gauges... expensive,...

    i have two sets of brute II gauges... expensive, but i think they're bad ass. one for 410, the other for 22. also, get the ballvalves on the end. i love 'em.

    one tech told me, you should get some...
  8. Replies
    15
    Views
    1,631

    just bought a klein backpack, haven't used it...

    just bought a klein backpack, haven't used it yet, but looks like it will work very well. i'm gonna use it for diagnostics mainly, and try not to overload...

    i really like the rubber on the...
  9. Replies
    20
    Views
    1,172

    i don't think it is the fan cycle so much as the...

    i don't think it is the fan cycle so much as the pressure issue. the fan cycle is detecting the liquid pressure (which is too low), and isn't cycling the fan on soon enough, by the time it does, the...
  10. Replies
    20
    Views
    1,172

    the thing is, i was hoping to save time by...

    the thing is, i was hoping to save time by pumping all the refrigerant into the condenser and essentially do the same thing... there is a cheap copper FD that was in the unit, then another filter...
  11. Thread: capacitor

    by wdshea
    Replies
    30
    Views
    1,751

    cant you damage a cap by shorting across the...

    cant you damage a cap by shorting across the terminals? thats why i suggest the "voltage test" across the terminals...
  12. Replies
    57
    Views
    2,398

    you can check your ground by checking continuity...

    you can check your ground by checking continuity between neutral and ground. Ground and neutral are electrically connected (bonded) inside the breaker box. though i don't know if the unit cares about...
  13. Thread: capacitor

    by wdshea
    Replies
    30
    Views
    1,751

    i always just check the mF against the rating......

    i always just check the mF against the rating... you can discharge a cap by setting your meter to VAC and stick it across its terminals.
  14. Replies
    20
    Views
    1,172

    ... first of all, i don't want to sell them...

    ...


    first of all, i don't want to sell them something they don't need, second i want to know why this system is acting the way it is.

    third, i assume you are kidding
  15. Replies
    20
    Views
    1,172

    if it were air, could i pump down the system, and...

    if it were air, could i pump down the system, and check the pressure against my PT chart? i realize that the LL Schraeder Valve would be blocked by the LL Service valve (when closed), but there is a...
  16. Replies
    20
    Views
    1,172

    sorry, it had been a long day. the 100 psig was...

    sorry, it had been a long day. the 100 psig was after i bypassed the fan cycle control so the unit would run. the 500/250 was what i was getting, but since the fan cycle control cut in was too high,...
  17. Replies
    20
    Views
    1,172

    500 psig at discharge, 250 at LLSV

    likely restriction, or is this possible?

    5 ton trane split system, condenser is on the roof. system cools a server room. at 55* ambient, i have ~100psig liquid pressure, close to zero subcooling,...
  18. Replies
    14
    Views
    1,224

    whats the subcooling? whats the temp. diff across...

    whats the subcooling? whats the temp. diff across the filter drier? whats the temp. diff. across the king valve? if you think there is a restriction there, i would check for refrigeration effect.
    ...
  19. Replies
    13
    Views
    1,043

    that's rather convenient, because i found a leak...

    that's rather convenient, because i found a leak at the fitting from the outlet of the indoor TXV to the distributor.

    what bunged up the check valve? not that i would try to clean it out and put...
  20. Replies
    13
    Views
    1,043

    How did you deduce that it was the indoor check...

    How did you deduce that it was the indoor check valve?
  21. Replies
    15
    Views
    1,206

    are there tools used to check the piston and...

    are there tools used to check the piston and bore, or is this simply a visual inspection? if air cooled, how do i check the wrist pin?
  22. Replies
    13
    Views
    1,043

    also, i've been told to only charge a heat pump...

    also, i've been told to only charge a heat pump in cool mode... is it possible to charge the unit in heat without a charging chart?
  23. Replies
    13
    Views
    1,043

    if properly charged, wouldn't my subcooling be...

    if properly charged, wouldn't my subcooling be higher than normal with low ambient and IAT at normal temp?
  24. Replies
    13
    Views
    1,043

    air to air heat pump, it's not literally water...

    air to air heat pump, it's not literally water hammer, but it sounds like it. the liquid line bangs like water does when it "hammers". I don't know SH... lineset is 3/8 and 7/8 by about 60'. the...
  25. Replies
    13
    Views
    1,043

    132 views and no one has any theories, at least?

    132 views and no one has any theories, at least?