Search:

Type: Posts; User: jciengineer

Search: Search took 0.00 seconds.

  1. Replies
    6
    Views
    1,970

    Changing the system clock was a good idea. I'm...

    Changing the system clock was a good idea. I'm wondering did that work?
  2. Replies
    7
    Views
    2,089

    RTD vs Thermisitor

    What do I do if my controller accepts a 10K thermisitor, but the spec is demanding RTD??? Any thoughts?
  3. Replies
    5
    Views
    836

    Thank you gentlemen, that information helps a lot.

    Thank you gentlemen, that information helps a lot.
  4. Replies
    6
    Views
    1,146

    I agree with amigo, that company out of Canada is...

    I agree with amigo, that company out of Canada is extremely knowledgeable when it comes to N2. I have spoke with them before and they are very nice to deal with. Other then that, I wish you good...
  5. Replies
    5
    Views
    836

    Thank you for the reply. I did try that and I...

    Thank you for the reply. I did try that and I got nothing using VT100, 9600 8-N-1 and I also tried auto detect with no luck.
  6. Replies
    5
    Views
    836

    Siemens Question

    Here is what I got. I'm looking to integrate a Siemens system into a FX-40 aka Jace. I have the "jar" file needed in the jace but I'm confused on how to hook it to the Siemens panel. The Siemens...
  7. Replies
    12
    Views
    1,346

    what's your email, I would be glad to send you...

    what's your email, I would be glad to send you some literature, glad to help
  8. Replies
    1
    Views
    656

    Optp22 Integration

    I am working on a integration from Opto22 to LON on the FX40. I'm using a device called a Field Server. I was wondering if anyone has either integrated from Opto22 or did something similar with a...
  9. Replies
    9
    Views
    1,061

    Honeywell is the only one that I know about. I...

    Honeywell is the only one that I know about. I think the model numbers that jayhawker listed are accurate.
  10. Replies
    5
    Views
    1,043

    The only idea that I have is to use the...

    The only idea that I have is to use the compatibility feature within XP. To do this, find the .exe file for GX9100 and right click it. Select either compatibility and run as windows 2000 or you may...
  11. Replies
    17
    Views
    3,750

    The -6 is the upgrade version, however it will...

    The -6 is the upgrade version, however it will install the full version even if you never had MTOOLS installed before. I have done this about a hundred times and I never had any problems.
  12. Replies
    17
    Views
    3,750

    http://www.energyequipment.com Ask for Dan...

    http://www.energyequipment.com

    Ask for Dan Jones, the part you want to ask for to get HVACPRO is

    MW-MTOOL-6

    (Trust Me)
  13. Replies
    8
    Views
    1,018

    Hey call 717-273-3021 they are an authorized...

    Hey call 717-273-3021 they are an authorized circon dealer. Ask for Terry.
  14. Replies
    8
    Views
    2,107

    First of all you can not hook a modem up to a JCI...

    First of all you can not hook a modem up to a JCI controller, UNT, VMA, DX, etc. The modem can only be placed on an N30 or another type of JCI front end. JCI also has two other front ends, the NCM...
  15. Replies
    8
    Views
    985

    one other thing, do you have the N30 port set for...

    one other thing, do you have the N30 port set for 9600? What is your retries set to. I know I had mine set for 3.
  16. Replies
    8
    Views
    985

    I'm sorry I didn't get a chance to look at my...

    I'm sorry I didn't get a chance to look at my database like I said I was going to. I recently moved into a new place and I'm still getting things in order. I'll try my best to look at it tonight. ...
  17. Replies
    8
    Views
    985

    That is weird. what does the message say when...

    That is weird. what does the message say when the device goes offline? What alarm or alarms do you have set up that are not working, give me one or two examples. Have you tried setting up an alarm...
  18. Replies
    8
    Views
    985

    I have been in your shoes before and not that...

    I have been in your shoes before and not that long ago either. I had a lot of problems as well. The good news is I got it to work, now here comes the bad news, I forget what I did to make it work. ...
  19. JCI's T600, much cheaper then H/W, about half the...

    JCI's T600, much cheaper then H/W, about half the price, mainly because you don't need a subbase with JCI's
  20. Replies
    10
    Views
    1,260

    I tried being cheap with this issue and none of...

    I tried being cheap with this issue and none of them will work. The only one that I seen work and also heard from others to work is the one from s2innovations.

    Good Luck
  21. With the contact of the relay tied into the hot...

    With the contact of the relay tied into the hot leg it's called switching the hot or sometimes called hi. Put the contact of the relay on the common leg and it's called switching low. Everyone does...
  22. Replies
    7
    Views
    1,035

    The T7350 is not replacing the T7300 there will...

    The T7350 is not replacing the T7300 there will still be both lines. I forget what is special about the T7350, I think it has something to o with modulating a damper, or economizer, I forget. The...
  23. Replies
    6
    Views
    937

    I have 2 possibilities for the communicating...

    I have 2 possibilities for the communicating t-stats, I'm not sure about the gateway. For the T-stats look into Johnson Controls T-600 line or Honeywells T7300 or T7350. Honeywells new vision pro...
  24. Replies
    9
    Views
    948

    How does the saying go, if you can't beat them...

    How does the saying go, if you can't beat them copy off them :)
  25. Replies
    9
    Views
    948

    I was wondering how people felt about the whole...

    I was wondering how people felt about the whole JCI and York thing. Lets hear what everyone thinks.
  26. Replies
    4
    Views
    1,101

    I'm sorry to hear that you were one of the many...

    I'm sorry to hear that you were one of the many to get the axe. Seimens is very good for techs.
  27. Replies
    22
    Views
    2,407

    FYI: Xp will work fine, I have sceen minimal...

    FYI:

    Xp will work fine, I have sceen minimal problems but there is a way to get around it. If there is a piece of JCI software giving problems, find the .exe file for that software and right...
  28. Replies
    2
    Views
    709

    Try this one: In the window where you have the...

    Try this one:

    In the window where you have the following folder:

    N2
    programs
    schedule
    etc...
  29. Replies
    25
    Views
    3,319

    I'm not sure where to start. First of all I love...

    I'm not sure where to start. First of all I love JCI but that doesn't mean I agree with everything they do and nor do I understand the reasons why they do the things they do.

    Every single person...
  30. Replies
    6
    Views
    1,659

    Well this is simple ohm's law. VA + VA = Total...

    Well this is simple ohm's law.

    VA + VA = Total VA

    VA / 24V (or whatever your voltage is) = amperage

    Remember VA is nothing but wattage. If you have a 120 wall light bulb in your home @ 120V...
  31. Replies
    14
    Views
    2,809

    Hey bud, hopefully I can steer you in the right...

    Hey bud, hopefully I can steer you in the right direction. Kele is great don't get me wrong but in this situation I would go else where. Try one of the following, i suggest the first one:

    1...
  32. Replies
    11
    Views
    1,759

    Yea I saw the web cast, It all looks good now JCI...

    Yea I saw the web cast, It all looks good now JCI just has to deliver what they talk about. They can talk the talk but can they walk the walk? I talked to a service guy who has run into equipment...
  33. Replies
    11
    Views
    1,759

    I do know for a fact that both the Branch and...

    I do know for a fact that both the Branch and ABCS's will still continue to carry Metasys. Their will be 2 new lines, one dedicated to the Branch which will be BACNET and another for the ABCS's...
  34. Replies
    11
    Views
    1,759

    I'm a little bit confused. Can you explain what...

    I'm a little bit confused. Can you explain what you mean by threats?
  35. Replies
    25
    Views
    10,310

    Try http://www.isa.org the company I work for...

    Try http://www.isa.org the company I work for gives training for a very low price but it's not going to work if your located in Canada. Check out the website I listed above, this maybe a saource...
  36. Replies
    11
    Views
    1,759

    Has anyone heard about the release date for the...

    Has anyone heard about the release date for the new Johnson Controls FX products? JCI originally said April 2005, but there is only a few days left this month, you do the math. If anyone has heard...
  37. Replies
    13
    Views
    3,016

    hey, integrationx I don't have answers for all...

    hey, integrationx

    I don't have answers for all of your questions but I do have some.

    Carrier bought automated logic just so they can be competive in the unit manufactuer controls market. Trane...
  38. Replies
    10
    Views
    1,906

    It sounds like it might be on Mcquays end. I...

    It sounds like it might be on Mcquays end. I thought Johnson hads a technical cutsheet about intergrating with McQuay. Check their website or else call tech support. I wish I could give you a...
  39. Replies
    5
    Views
    1,440

    control_noob hit the nail on the head, he is...

    control_noob hit the nail on the head, he is absolutly correct with his diagnose.
  40. Replies
    10
    Views
    1,906

    I beat you are using a JCI TEC controller??? If...

    I beat you are using a JCI TEC controller??? If so I know what your problem is I just had the same problem. I would have to look again to see what I did. Their is a point that needs to be overrode...
  41. Replies
    1
    Views
    1,641

    Honeywell Pro Stat Info

    Goto this website and search for what you need.

    http://www.asc.honeywell.com

    If you have any more problems, I work for a HVAC Controls Distributor. Call 1-800-360-3324 or visit
    ...
Results 1 to 41 of 41