Search:

Type: Posts; User: Furnaceguy85

Page 1 of 3 1 2 3

Search: Search took 0.05 seconds.

  1. Replies
    2
    Views
    231

    Thank you that was my mistake I need to get eyes...

    Thank you that was my mistake I need to get eyes checked lol
  2. Replies
    2
    Views
    231

    Fieldpiece SRH3

    Just received my new srh3. Was playing with it and noticed a possible problem. In normal mode you can cycle through 3 different readings dry bulb, wet bulb, and %rh. Which is displayed on the top...
  3. Replies
    10
    Views
    779

    We installed a new boiler next day

    We installed a new boiler next day
  4. Replies
    10
    Views
    779

    I never got a date code of of it. They said it...

    I never got a date code of of it. They said it was original I think the house was built in the 60s.the rust was from my guess spillage from burners.boiler was non operable never tried to fire it when...
  5. Replies
    12
    Views
    784

    It is a makeshift 6-4 reducer out of some sort of...

    It is a makeshift 6-4 reducer out of some sort of scrap metal
  6. Replies
    10
    Views
    779

    Boiler fun

    Customer called for a pump coupler. Asked her when she wanted new boiler installed353301
  7. Replies
    12
    Views
    784

    80% venting scary

    Single wall dryer vent. Lol customer didn't see the danger here.353151
  8. Replies
    13
    Views
    1,163

    Sheet metal special

    These Wonderful pics taken by a co worker customer paid over 3300 for this side job install. Sad353121353131353141
  9. Replies
    342
    Views
    45,115

    Last service call I ran yesterday. Lady says...

    Last service call I ran yesterday. Lady says furnace making a real bad vibration. I turn it on sounds like a off balance blower. I said ok easy fix probably something stuck in wheel sinse there was...
  10. Replies
    34
    Views
    2,632

    got my tools stolen 3 years ago. i forgot to put...

    got my tools stolen 3 years ago. i forgot to put my puck lock on one night in front of my own house. woke up in the morning and everything was gone. i probally lost over 2000 worth. i still get...
  11. Replies
    4
    Views
    446

    looks like that guy wrote alot of detail about...

    looks like that guy wrote alot of detail about that to get $15 lol.i guess my customers installed rusty one is worthless
  12. Replies
    4
    Views
    446

    Duct music

    Has anyone ever seen this before. Seen it mounted on duct on a service call. Asked customer about it and he had no idea said it was there when he bought the house277711
  13. Replies
    35
    Views
    4,512

    they pulled the drain plug out so condensate...

    they pulled the drain plug out so condensate would run straight down over controls.

    the house is about 1200 sq ft. the return drop wasnt even secured to furnace.the lady bought the house last year...
  14. Replies
    35
    Views
    4,512

    Perfect match system

    277381150000 btu furnace matched up with a 2.5 ton a-coil. Customer called because sheet metal tape blew off. Needless to say the idiot contractor who put this in can't be found.
  15. Replies
    10
    Views
    1,853

    Dog damage

    277001customer said her dog just started urinating on it this year. She was shocked when I told her there was no refrigerant left in system
  16. Replies
    9
    Views
    551

    check humidifier on plenum. had a customer that...

    check humidifier on plenum. had a customer that never changed his humidifier pad. the pad turned all black and moldy and chunks fell onto acoil and drain pan.
  17. Replies
    23
    Views
    952

    i eat while driving between calls. carry a cooler...

    i eat while driving between calls. carry a cooler of mainly water. sometimes vitaminn water if they are on sale. i do have a real bad habbit of not packing a lunch and i usually just stop anywhere...
  18. i tried asking our installers to note the...

    i tried asking our installers to note the metering device.needless to say it does not get done very often. thankfully most new installs have a cased acoil which has a easy to remove panel and...
  19. Replies
    18
    Views
    1,453

    All the supply houses I go to sell it. It should...

    All the supply houses I go to sell it. It should be able to handle the high pressures of 410A or I'd hope they wouldn't sell it. It is cheaper cause of less silver content than 15% sil fos. It has a...
  20. Replies
    8
    Views
    541

    found a leak yesterday on a unit another tech put...

    found a leak yesterday on a unit another tech put dye in end of last year. was easy to spot the A-coil drain pan was stained a bright yellow from all the condensation draining out.
  21. Replies
    10
    Views
    678

    I think you can but I'd check installation...

    I think you can but I'd check installation manual. Do you have a water tank next to furnace that also needs combustion air? It might be better to run a fresh air vent for whole furnace/utility room.
  22. I have. Had the hs35 for 2 years now. I have the...

    I have. Had the hs35 for 2 years now. I have the phschrometer head attachment and the vacuum gauge attachment. Both work well. Haven't used vacuum gauge since I bought the sman3. I don't think you...
  23. Replies
    14
    Views
    1,250

    i use mine for both r22 and 410a. i also bleed...

    i use mine for both r22 and 410a. i also bleed liquid back into low side. if hoses are left with excess amounts of oil i will flush them.
  24. Replies
    20
    Views
    1,457

    I didn't know they make a hard case were can you...

    I didn't know they make a hard case were can you get that?can you keep hoses and temp clamps on meter while in hard case?
  25. Replies
    20
    Views
    1,457

    Mine cracked the same way on left side vertical...

    Mine cracked the same way on left side vertical from bottom up. Gauge still works fine.I always put mine back in the pouch and am careful with it.
Results 1 to 25 of 51
Page 1 of 3 1 2 3