Search:

Type: Posts; User: beenthere

Page 1 of 20 1 2 3 4

Search: Search took 0.88 seconds.

  1. Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  2. Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  3. Thread: AOP post

    by beenthere
    Replies
    4
    Views
    112

    That thread was originally in the General forum....

    That thread was originally in the General forum. I moved it to AOP. I failed to put a post in it that I moved it. You posted in it while it was still in the General forum. About an hour before I...
  4. Thread: AOP post

    by beenthere
    Replies
    4
    Views
    112

    That thread was originally in the General forum....

    That thread was originally in the General forum. I moved it to AOP. I failed to put a post in it that I moved it. You posted in it while it was still in the General forum. About an hour before I...
  5. Replies
    15
    Views
    217

    Stop trying to run the heat pump in heat mode...

    Stop trying to run the heat pump in heat mode when its hot outside. The safeties are doing their jo and protecting the compressor. But if the safety fails to shut it off, you WILL damage the...
  6. Thread: AOP post

    by beenthere
    Replies
    4
    Views
    112

    Not sure what you mean. If you have a reply...

    Not sure what you mean. If you have a reply posted in an AOP thread. Good chance it was moved to AOP after you posted.


    Got a link?
  7. Replies
    16
    Views
    343

    Install blower motor and new capacitor. Check...

    Install blower motor and new capacitor. Check voltage, amp draw, and that you have the rotation correct. Temp delta across the heat exchanger or indoor coil. Inform customer that you see no obvious...
  8. Replies
    9
    Views
    457

    Yep, GSCs have one in them from the factory.

    Yep, GSCs have one in them from the factory.
  9. Replies
    8
    Views
    205

    Gross over charge, and or a restricted LLFD can...

    Gross over charge, and or a restricted LLFD can cause the liquid line temp to be at, below or near the outdoor temp. GSCs come with a LLFD installed in the cabinet, and it is often over looked. And...
  10. Seen more then one unit where a tech decide air...

    Seen more then one unit where a tech decide air flow was adequate by holding their hand over a register and feeling a strong air flow. Or by holding their hand at the return, and commenting that its...
  11. Replies
    16
    Views
    343

    Only the thread starter, and Pro * members can...

    Only the thread starter, and Pro * members can reply to a thread in the AOP forums.



    So after 2 hours of not finding the reason. Do you bill them, or eat that time.
  12. When an over charged system freezes up. It is...

    When an over charged system freezes up. It is usually caused by a second problem, which is what caused someone to over charge it, and that problem is often low air flow.
  13. Replies
    12
    Views
    342

    Or they could have connected the coil's over flow...

    Or they could have connected the coil's over flow drain, and then the water would have over flowed through it. And not have gotten on the control board. Its a safety the manufacturer designed into...
  14. When you initially topped off the charge, you had...

    When you initially topped off the charge, you had it grossly over charged. Target SH was 17, and you had 4.5°.

    Leak was probably bigger then you thought.

    Model numbers would tell us what SEER...
  15. Replies
    8
    Views
    205

    With 32°F SC, your not flashing in the liquid...

    With 32°F SC, your not flashing in the liquid line with only a 10PSIG pressure drop to the evap coil(10 PSIG pressure drop is only a 3° loss of SC, 20 PSIG would only be 7°). Unless the LLFD is after...
  16. Replies
    22
    Views
    757

    Its explained in the open Tech to Tech forums, in...

    Its explained in the open Tech to Tech forums, in several threads.
  17. Efficiency is the only difference. However,...

    Efficiency is the only difference.

    However, its very common for someone to think they need a larger A/C when the real problem is the under sized duct work.

    The load calc numbers you posted, say...
  18. Best to have it connected to the HUM terminals.

    Best to have it connected to the HUM terminals.
  19. Replies
    7
    Views
    193

    1979.54 BTUS an hour at 80°F and 60% RH.

    1979.54 BTUS an hour at 80°F and 60% RH.
  20. What temp are you setting the thermostat to.

    What temp are you setting the thermostat to.
  21. Replies
    22
    Views
    757

    Need to check the super heat and sub cool to know...

    Need to check the super heat and sub cool to know what is going on with it.
  22. Replies
    22
    Views
    757

    Merged threads.

    Merged threads.
  23. Replies
    12
    Views
    342

    Make sure the door is on correctly.

    Make sure the door is on correctly.
  24. The model number doesn't contain any year...

    The model number doesn't contain any year information.
  25. Replies
    13
    Views
    648

    Yep. Ask the customer to put the dog in a room...

    Yep. Ask the customer to put the dog in a room that you/he won't be in. Explain to the customer that you/he doesn't get along well with dogs. And teh dogs sense the fear.
  26. As an Engineer, you should be able to read a...

    As an Engineer, you should be able to read a diagram. Look at the diagram, it will also have a legend.

    If you need help identifying the parts in that pic. You need to take HVAC courses, as you...
  27. Moved to Tech to Tech commercial forum. You...

    Moved to Tech to Tech commercial forum.

    You need to make 15 post of some technical substance, and then fill out the application. Follow the instructions in the below link.
    ...
  28. A static pressure test can be done.

    A static pressure test can be done.
  29. Carrier isn't using the Bristol compressor...

    Carrier isn't using the Bristol compressor anymore, so no compressor problems.

    2 stage is more for comfort then savings. Although by reducing the indoor humidity, many people can set their indoor...
  30. Replies
    6
    Views
    249

    Should be no problem for a contractor to find a...

    Should be no problem for a contractor to find a replacement coil.
  31. Replies
    15
    Views
    652

    Thanks for the update.

    Thanks for the update.
  32. If the duct ork is border line sized. It can...

    If the duct ork is border line sized. It can shorten the life of the VS blower motor's module.
  33. Closing off registers when you have a VS blower....

    Closing off registers when you have a VS blower. Increases the wattage use of the blower.
  34. Replies
    23
    Views
    636

    Since his liquid line temp is so close to the...

    Since his liquid line temp is so close to the ambient temp. Its probably more restricted then the temp difference is showing. And if the liquid line temp he posted is before the filter drier, then...
  35. Knowing the actual heat loss of your home. And...

    Knowing the actual heat loss of your home. And then plotting a balance point graph, would tell if dual fuel or electric aux heat is better for you.
  36. Used them a few times. They can save a customer...

    Used them a few times. They can save a customer some money. And a tech a lot of time not having to change out a compressor.
  37. Replies
    31
    Views
    922

    I'd want the thermostat to control staging.

    I'd want the thermostat to control staging.
  38. Replies
    31
    Views
    922

    Looks okay for the current configuration.

    Looks okay for the current configuration.
  39. Replies
    31
    Views
    922

    Sorry, your going too far into DIY territory. If...

    Sorry, your going too far into DIY territory. If I answer your question, I'll have to slap my own hands.
  40. Could be that its just going to take a while for...

    Could be that its just going to take a while for it to freeze up. Or that the TXV is not letting any refrigerant go through it now.
  41. Replies
    39
    Views
    1,545

    Click it.

    Click it.
  42. Replies
    17
    Views
    570

    Prices removed, as posting them is against site...

    Prices removed, as posting them is against site rules.
  43. Sounds like this tech knows what he is doing.

    Sounds like this tech knows what he is doing.
  44. Replies
    31
    Views
    922

    It is not disconnected.

    It is not disconnected.
  45. Replies
    7
    Views
    212

    Made this its own thread.

    Made this its own thread.
  46. Replies
    15
    Views
    652

    Yep, head is low. Goodman specs say it should...

    Yep, head is low. Goodman specs say it should have at least a 22°F delta across the coil. So sounds like a low air flow problem. So you are probably on the right track that the evap coil needs to be...
  47. Replies
    7
    Views
    450

    LOL, I hate when I do that. I'm lucky and can...

    LOL, I hate when I do that. I'm lucky and can delete my oops, hours, even years later. :grin2:
  48. In June you had: 5 days of temps over 100 4...

    In June you had:

    5 days of temps over 100
    4 days of temps of 96 plus
    11 days of temps between 90 and 95

    In July you had:

    4 days of 100 plus
    4 days of 96 plus
  49. Those electric bills don't look that high for the...

    Those electric bills don't look that high for the temps your area has.


    PS: The posting of electric, gas, or oil rates is allowed.
  50. Have you tried. O'Neill Bagwell Cooling &...

    Have you tried.

    O'Neill Bagwell Cooling & Heating
    913 8th Ave N
    Myrtle Beach, South Carolina 29577-3845
    913 8th Avenue North
    Myrtle Beach, SC 29577

    Phone: 843-385-2220
    Fax: 843-839-2220
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards