Search:

Type: Posts; User: MaxBurn

Page 1 of 14 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    6
    Views
    258

    FYI, your link at the bottom goes to the default...

    FYI, your link at the bottom goes to the default IIS7 page for an unconfigured site.
  2. Replies
    19
    Views
    1,352

    Not getting any BACnet data when using the...

    Not getting any BACnet data when using the default IP is a problem, the stuff might be legacy CMnet. If you don't have the cable or software you need to call Liebert.
  3. Replies
    19
    Views
    1,352

    The name of the module pictured doesn't match the...

    The name of the module pictured doesn't match the thread it's posted in so disregard the advice. For the SiteGate you need a special cable to plug into the access port and depending on how the...
  4. Replies
    19
    Views
    1,352

    The default IP is 192.168.168.x where x is...

    The default IP is 192.168.168.x where x is whatever the rotary switch number is.

    Assuming this is a SiteLink-E dip switch 1 must be set to enhanced access to get the terminal menu to get IP...
  5. Replies
    5
    Views
    324

    Those modules are OEMCtrl modules programed and...

    Those modules are OEMCtrl modules programed and sold by the chiller manufacturer.

    Only recently (end of 14) has there been any inroads to trying to join up ALC dealers and reps to be able to...
  6. Replies
    23
    Views
    915

    Bacnet quick test is pretty nice to have, I use...

    Bacnet quick test is pretty nice to have, I use it now and again to simplify troubleshooting.
  7. Replies
    11
    Views
    417

    A trick we use to schedule/automate reports: On...

    A trick we use to schedule/automate reports: On the WebCTRL side we can trigger a reporting action for email that will in turn then run a report and attach it to the email, do you have the ability to...
  8. Replies
    14
    Views
    627

    Where are you? ...

    Where are you?

    http://www.automatedlogic.com/locations/northamerica/
  9. Replies
    5
    Views
    252

    At a minimum the Liebert tech that started it up...

    At a minimum the Liebert tech that started it up should have told you the comm details and which program is on which port of the SiteLink, things like LAM on port 2 or iCOM on port 5 etc. For the...
  10. DD-WRT or something similar? So you place a...

    DD-WRT or something similar? So you place a router on each remote sites and another with the front end to connect to?
  11. Replies
    8
    Views
    360

    Is it an iCOM DS unit with an intellislot option...

    Is it an iCOM DS unit with an intellislot option card in it? One of the manuals in here should have the points if so. ...
  12. Replies
    8
    Views
    360

    I think there might be something that has to be...

    I think there might be something that has to be refreshed every so often so it doesn't return to default. Seems I remember something like that, read the fine print.
  13. Some vendors document points differently, some...

    Some vendors document points differently, some start with 0 and some start with 1. Liebert seems to mostly start with 1 as the first point address it seems. Your BMS might like to start addressing...
  14. Can you bring it in as an analog and then call it...

    Can you bring it in as an analog and then call it an alarm if it matches a value or range or exceeds a threshold? I can tell you about the Liebert unit and Modbus but I don't know a thing about your...
  15. And the other points are likely unsigned integer...

    And the other points are likely unsigned integer 16 bit if it hasn't already been mentioned somewhere.
  16. 469, 10232(1), Unit Off 470, 10233(1), Unit On...

    469, 10232(1), Unit Off
    470, 10233(1), Unit On
    471, 10234(1), Unit Partial Shutdown
    472, 10235(1), Unit Shutdown
    473, 10236(1), High Power Shutdown
    474, 10237(1), Unit Standby

    These points...
  17. None of them will be float if I remember right....

    None of them will be float if I remember right. Try Uint16 for all analog points.
  18. Replies
    10
    Views
    1,137

    These units ship with the BACnet points disabled...

    These units ship with the BACnet points disabled (out of service), they must be enabled before you can write to them. That can be done through BACnet or through the BACnet setup tool.
  19. Your error illegal data address error sounds like...

    Your error illegal data address error sounds like somehow it already worked out the slave address somehow or it was the same as the default?

    For that unit I'm guessing you are plugged into an...
  20. A 30k register address is modbus function code 4...

    A 30k register address is modbus function code 4 so you could try splitting those up for your command line syntax, function 4 address 130 for return humidity for example.

    The info contained in...
  21. Replies
    38
    Views
    1,719

    Not an expert but the OA units I just worked with...

    Not an expert but the OA units I just worked with were two stage and the first stage had hot gas reheat with a variable DAT setpoint. The DAt setpoint and reset limit on ours was set with dip...
  22. Replies
    13
    Views
    732

    That x8160 is a pretty special board, not sure...

    That x8160 is a pretty special board, not sure I've even seen one, this an OEM board?

    You could pick up a x16160 ($1,725 on ebay) and drop it in with no changes. Or you could combine a x880 and a...
  23. Replies
    7
    Views
    363

    Is this legacy exec6 CMnet? If so then the LGE...

    Is this legacy exec6 CMnet? If so then the LGE needs to have the CEM driver loaded into it via direct connect before it will respond to CMnet/IP.

    If you need execB you might have a legacy...
  24. Replies
    1
    Views
    300

    Looks like a yes if you are referring to a Tracer...

    Looks like a yes if you are referring to a Tracer BCI-R ReliaTel in a Precedent, Voyager, or Odyssey.
  25. Replies
    9
    Views
    646

    The wheel might not care but the wipers should it...

    The wheel might not care but the wipers should it rubs against probably do.
  26. Replies
    6
    Views
    476

    Not really certain, again it depends on how they...

    Not really certain, again it depends on how they set up the SNMP agent in the device. I want to say Liebert did that. Hit up ireasoning.com and grab the MIB browser, there should be a way to walk a...
  27. Replies
    6
    Views
    476

    Well seems every SNMP device is a bit different...

    Well seems every SNMP device is a bit different but some of them do have status points that reflect the alarm conditions, I want to say the Liebert UPS have this. In that case it's the same as...
  28. Replies
    3
    Views
    600

    I've never done it but you are supposed to be...

    I've never done it but you are supposed to be able to do all the devices on a CMnet in one shot, assuming they are capable of execB. If you have a bunch that might be worth looking at.
  29. Replies
    6
    Views
    476

    SNMP alarms are traps that get sent from the UPS....

    SNMP alarms are traps that get sent from the UPS. Is the interface in the UPS set up to deliver traps to the Babel Buster device?
  30. Thread: MAC

    by MaxBurn
    Replies
    3
    Views
    298

    I have pushed ALC support a couple times for the...

    I have pushed ALC support a couple times for the ability to use WebCTRL on a Mac, I think it would make a good combination and alternate platform for servers and development. That's considering the...
  31. Replies
    5
    Views
    812

    Sometimes that's hard to get info, you need to...

    Sometimes that's hard to get info, you need to cultivate a contact in their IT group to help with things like that. If that doesn't work we have used our companies email server at some customers, but...
  32. Replies
    35
    Views
    3,221

    I'm not really a fan on needing the decoder ring...

    I'm not really a fan on needing the decoder ring to be able to read what they are saying and change settings on them. Not really friendly.
  33. Replies
    3
    Views
    275

    Advice from WebCTRL likely the same: Do the...

    Advice from WebCTRL likely the same: Do the latest cumulative patch, it contains all prior patches. If any patch was released after that cumulative you would have to apply that. In general you can't...
  34. Replies
    7
    Views
    582

    From what little I have seen I agree. Our senior...

    From what little I have seen I agree. Our senior integrator has poured a TON of time into these DBACS systems and it has not been a smooth road for our customers. We are also adding in a small point...
  35. Replies
    6
    Views
    672

    I don't work from scratch but I edit the heck out...

    I don't work from scratch but I edit the heck out of floorplan graphics with regular old mspaint as well, and use the floodfill and some random color for the color regions. Not sure how the pros do...
  36. Supervision works happily under windows 98 and...

    Supervision works happily under windows 98 and missing some features under windows XP, both which are EOL and shouldn't be allowed on a customer site. Also supervision was EOL something like eight...
  37. Replies
    6
    Views
    674

    You really need to know what you are doing and...

    You really need to know what you are doing and spend a decent amount of time if you want to manually handle BBMDs, which is great and all but SiteBuilder can do it for you. In this situation consider...
  38. Replies
    6
    Views
    674

    Could be you don't have bindings, hit the check...

    Could be you don't have bindings, hit the check bindings button on the driver page. If it doesn't say "alarms will be delivered" near the bottom than you don't have your BACnet bindings set up...
  39. Replies
    20
    Views
    989

    Sounds like 1800LIEBERT time.

    Sounds like 1800LIEBERT time.
  40. Thread: BBMD vs VPN

    by MaxBurn
    Replies
    43
    Views
    4,401

    This right here could save us some headaches with...

    This right here could save us some headaches with some customers fooling with their network all the time...
  41. Thread: BBMD vs VPN

    by MaxBurn
    Replies
    43
    Views
    4,401

    Cisco then sold Linksys to Belkin almost two...

    Cisco then sold Linksys to Belkin almost two years ago, another company I dont trust with the job. Who knows who is providing software updates for those now.
  42. Thread: BBMD vs VPN

    by MaxBurn
    Replies
    43
    Views
    4,401

    Excellent point, I've also been burned by cheap...

    Excellent point, I've also been burned by cheap consumer routers and I'll never get anything with the words Dlink or Linksys on them again. I'm thinking some of the better SOHO routers from the big...
  43. Thread: BBMD vs VPN

    by MaxBurn
    Replies
    43
    Views
    4,401

    That's an interesting comment on the speed...

    That's an interesting comment on the speed difference. I'm not sure why that might be.

    How are you all handling the tech training for these VPN devices deployment, repair and troubleshooting?
    ...
  44. Replies
    3
    Views
    515

    Planning the network layout for devices that need...

    Planning the network layout for devices that need to talk to each other is one that is starting to be an issue on some sites I've seen. Good mention kontrol.
  45. Replies
    20
    Views
    989

    I don't believe it is, all you are really doing...

    I don't believe it is, all you are really doing with he switches is changing the media type on the CMnet port. So if it's part of the same system that could be a concern. Can you download to the...
  46. Replies
    20
    Views
    989

    I guess the key question is does it still work on...

    I guess the key question is does it still work on ARCnet if you put it back? ;)

    Other random thoughts
    For MS/TP the other dip switches need to be left off. You don't want to wire to port A or...
  47. Replies
    20
    Views
    989

    Is this a SiteLink-12 2mb with no network port?...

    Is this a SiteLink-12 2mb with no network port? Or is it a SiteLink-12E with a network port?

    IF a SiteLink-12 2mb currently working on ARCnet you should be able to move the ARCnet/9600/38400 3 pin...
  48. Replies
    6
    Views
    592

    How difficult is it to get the right parts?

    How difficult is it to get the right parts?
  49. Replies
    32
    Views
    5,217

    Submit to wall of shame?

    Submit to wall of shame?
  50. Replies
    19
    Views
    1,352

    If I remember correctly to pull info out of the...

    If I remember correctly to pull info out of the SiteLink you want modbus function code 3 which results in a 4xxxx register request.

    I think the intellislot cards support both function code 3 and...
Results 1 to 50 of 697
Page 1 of 14 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards