  1. Siemens TEC resetting itself every 30-40 seconds

    I have a newly installed Siemens TEC, application 2050 that is resetting itself every 30 to 40 seconds on average.....it loses connection with insight and physically powers itself off and then back...
  2. Replies
    8
    Views
    936

    Siemens TEC Application 2050

    I've got a few of these that I suspect are wired on opposite DO's from where they should be and it's causing the control to be reversed. Can anyone email me the guide for 2050 that would tell me...
  3. AB Powerflex VFD comm. to Siemens P1 FLN @ 9600 baud

    I have had hit and miss success hooking up trunks consisiting of one to six Allen-Bradley Powerflex 400 VFD's to FLN trunks in our Siemens control panels. Sometimes I hook them up and configure the...
  4. USB connection to PXC100 modular for config

    I'm trying to perform initial addressing, BLN naming, etc. type tasks on a brand new Siemens PXC100.96a controller for our apogee system. I have one of those printer type USB cables with the type...
  5. Replies
    5
    Views
    1,077

    That some interesting info in regards to the...

    That some interesting info in regards to the "true bacnet" vs. P2 loaded with bacnet drivers. I wonder if there is any visual way to tell by looking? I'm guessing its the latter but it was put in...
  6. Replies
    5
    Views
    1,077

    BACnet Raypack to Siemens PXC modular

    We have a Siemens panel that already has the BACnet drivers in it and is currently talking to 3 BACnet capable York Chillers. I'd like to also add 2 Raypack Hybrid + boiler controllers onto the FLN...
  7. Replies
    0
    Views
    677

    Danfoss Turbocor Remote Monitoring

    I believe the equipment we have is capable of handling remote communications to the two turbocor compressors we have in another building over tcp/ip.

    There is a 4 port serial device server (Moxa...
  8. Replies
    7
    Views
    1,183

    How would one go about checking for "dead JNL"...

    How would one go about checking for "dead JNL" files? Our server based Insight is also slow, not hours slow though.
  9. Replies
    7
    Views
    1,196

    Alright, I got into the SCT using the second...

    Alright, I got into the SCT using the second method, and am currently synchronizing the archive. Hopefully this is the right thing to do.
  10. Replies
    7
    Views
    1,196

    I'm sorry, but what is SCT? This Metasys system...

    I'm sorry, but what is SCT? This Metasys system is all new to me, since we use Insight at our other buildings. The person who normally does this here is out on extended mecical leave so I am trying...
  11. Replies
    7
    Views
    1,196

    Metasys graphics backup

    The techs at one of our sites that I'm not familiar with have reported one of their graphics is missing. It was a summary page with key info from each of the buildings AHU's on it. The system has...
  12. Replies
    3
    Views
    595

    JCI NAE alarm clearing

    Does anyone know how to clear several or all of the alarms on an NAE in one batch? There are tons of them that would take forever to go through and clear one at a time as they "pop up".
  13. Replies
    18
    Views
    4,057

    Thanks for putting this up, I downloaded the file...

    Thanks for putting this up, I downloaded the file and it looks like a pretty slick interface for setting up AEM's. Is there a way to upload the configuration that's already in an existing one to see...
  14. Replies
    18
    Views
    4,057

    Figured this one out by trial and error. I had...

    Figured this one out by trial and error. I had the baud rates set right but the Modem (Enable/Disable) parameter in the field panel needs to be set to "disabled" when connected to an AEM. Seems...
  15. Replies
    18
    Views
    4,057

    I figured out the default password....it is...

    I figured out the default password....it is "system" for future reference.

    Now for the rest of my problem...

    What I've got is a remote BLN that's been functioning okay for at least a few years...
  16. Replies
    18
    Views
    4,057

    Does anyone know the default password for an AEM...

    Does anyone know the default password for an AEM 2100?
  17. Replies
    7
    Views
    1,150

    I didn't have the "original" configuration file...

    I didn't have the "original" configuration file but I was able to upload the configuration from the controller. I then printed out the Q/A section of it and then created a brand new program with the...
  18. Replies
    7
    Views
    1,150

    VAV100-0 trouble

    I've got a JCI VAV controller that is behaving weird by locking almost all of its values at 0. It is tied into a Siemens Apogee Insight workstation and I have attached the screen display. Other...
  19. Report for points currently in OPER priority?

    I'm trying to find a way to see just the points on the system (Siemens Apogee with Insight 3.10) that are currently in the OPER priority level but can't seem to figure out how. Anyone know?
  20. Ah, I get it now. I never knew that virtual...

    Ah, I get it now. I never knew that virtual points could be assigned an address until I clicked on the three periods next to the empty box where a conventional address would go. Then I also created...
  21. I'm not sure that that means exactly. My command...

    I'm not sure that that means exactly. My command point it "AB.CTWR1.SS". Triggering that point on will start my fan.
  22. For example I was trying to set it up like this:...

    For example I was trying to set it up like this:

    01151 C PROOF STATUS FOR FANS¶
    01152 IF ("AB.FAN1.CURRENT" .GT. 0.00) THEN ON("AB.CTWR1.SS#2")
  23. Siemens - L2SL point set up as virtual proof

    I'm trying to set up an L2SL point to use a virtual proof point instead of a hard wired input from a current sensor. I was then going to set up a logic statement in PPCL to trigger this virtual...
  24. Replies
    4
    Views
    1,024

    I haven't tried running it at 60 Hz in hand as of...

    I haven't tried running it at 60 Hz in hand as of yet. It will run there in auto but only for about 12 minutes or so. Everything looks okay in the settings as far as I can tell. The drive has been...
  25. Replies
    4
    Views
    1,024

    F64 - Drive Overload Fault

    I've got an Allen-Bradley VFD (Powerflex 400) that's been having overload faults for no clear reason. It is driving a single cooling tower fan. I can run it in hand at around 42 Hz and it does...