Search:

Type: Posts; User: morris-jenkins

Search: Search took 0.00 seconds.

  1. Replies
    8
    Views
    1,023

    windows are expensive but they let alot of heat...

    windows are expensive but they let alot of heat gain and loss from your house. insulate everything you can wall floors attic .if you cant afford to change the windows then look at storm windows if...
  2. Replies
    34
    Views
    2,986

    yes you can use a heating boiler to heat your...

    yes you can use a heating boiler to heat your domestic hot water.........its great if done right...i renovated 2 century old homes one in nc and one in clv,oh if you can hold out tighten up the house...
  3. has the job been permitted..........if so than...

    has the job been permitted..........if so than the inspector will let you know if you need to be concerned if it is single wall pipe then yes be concerned as for front cabinet clearences its always...
  4. Replies
    16
    Views
    1,905

    just a tip that alot of ppl seem to over look...

    just a tip that alot of ppl seem to over look when upping the tonnage of a system is the return duct work make sure they check out hte duct work and that its sized right for the unit you want if its...
  5. flex is a great product as long as it is...

    flex is a great product as long as it is installed correctly,as for ductboard its a horrible product and should be done away with. over time becomes a breeding ground for types of fungal growth and...
  6. Replies
    3
    Views
    1,118

    need help!bar owner buddy has a beverage air...

    need help!bar owner buddy has a beverage air reach in chest style cooler..short story is compressor locked,broke the suction line,loss all the refrigerant....the compressor is a tecumseh lpn 5545...
  7. Replies
    3
    Views
    670

    adding the 7th supply could actually help just...

    adding the 7th supply could actually help just remember that your furnace cant put out any more air than what it takes in meaning you cant get 1000 cfms out of your furnace if it only has 800 cfms...
  8. with gas prices on the rise ask about a 90%...

    with gas prices on the rise ask about a 90% efficiency furnace and have the cooling coil replaced. make sure you ask if your return duct system is large enough. if its not then you'll starve that new...
  9. Replies
    16
    Views
    2,275

    bubble wrap duct insullation? never seen it who...

    bubble wrap duct insullation?
    never seen it who makes it and is there a big diff in price?.........as for me i only deal with wrapped. liners if not installed correctly can fail and block air flow....
  10. Replies
    2
    Views
    791

    bought a beer cooler from a closed down bar it...

    bought a beer cooler from a closed down bar it cools but doesnt get down below 50 degrees uses 134a was just wandering if i can use the little 12oz cans to charge it and what kind of pressues should...
  11. Replies
    4
    Views
    953

    thanks for info guys

    thanks for info guys
  12. Replies
    4
    Views
    953

    im looking to relocate to the panama city area of...

    im looking to relocate to the panama city area of florida.and was looking at some job prospects when i thought i would ask here if any knows of or has worked for a company called Peaden heating and...
  13. Replies
    30
    Views
    3,209

    just wanted to say i work for a very good company...

    just wanted to say i work for a very good company that pays its installers comission i think its great. I split a 11 percent commision with my helper. We average close to 50 an hr thats dollars and...
  14. u said these are new construction dont they have...

    u said these are new construction dont they have inpectors there or atleast code enforcement
  15. Replies
    7
    Views
    1,499

    other thing you should have your hvac contractor...

    other thing you should have your hvac contractor do is look at your duct work and do a static pressure test on the hvac system to make sure your blower isnt working harder than it needs to to move...
  16. Replies
    7
    Views
    1,499

    me i would fix the basement problem and then i...

    me i would fix the basement problem and then i would look into a dual fuel system its a very efficient set up its a combination of a heat pump and a gas furnace pair a 14 seer heat pump with a 90%...
Results 1 to 16 of 21