  1. Replies
    17
    Views
    2,630

    I like his vest , i have to get meone of those...

    I like his vest , i have to get meone of those lol j/k
  2. Replies
    6
    Views
    1,671

    Lol how did they pass inspection with it like...

    Lol how did they pass inspection with it like that?
  3. Replies
    29
    Views
    3,902

    I usually use grey Pookie it doesnt stand out as...

    I usually use grey Pookie it doesnt stand out as much , but any pookie is better than no pookie at all
  4. Personally I think thats a hack at work....No...

    Personally I think thats a hack at work....No pride in his work at all, but i must admit have seen other guys do the same thing, always in a hurry...That would be a fast way to lose a customer to...
  5. There is a difference betwen them so Ill make it...

    There is a difference betwen them so Ill make it an easy explanation,

    1st Suction stops are usually use with a t-stat or with an epr valve.

    2nd Having said that the suction stop will allow more...
  6. Well i guess he can say he insulated the kd pipe...

    Well i guess he can say he insulated the kd pipe to prevent sweating ....LOL I got a good laugh at that one
  7. Thread: Horses A@@

    by luvcldair
    Replies
    4
    Views
    1,643

    Somedays You Think Our Jobs Suck ...

    Somedays You Think Our Jobs Suck


    http://www.break.com/index/horsepoo11.html
  8. Replies
    2
    Views
    577

    Out here in So Calif its very busy...I have...

    Out here in So Calif its very busy...I have several friends that do ammonia work and they are never looking for hours, one down fall i see for them is they work AOLT of graveyard shifts when the...
  9. Replies
    9
    Views
    1,053

    Depends on where you live but out here in Calif,...

    Depends on where you live but out here in Calif, if you have a totally sealed house with double pane windows and gaskets around your doors, basically air tight...

    back in the late 80s this was a...
  10. Replies
    2
    Views
    905

    Ditto i got a good laugh too thanks for the post

    Ditto i got a good laugh too thanks for the post
  11. Replies
    28
    Views
    1,428

    Do The Crime, Play The Fine..........Enough Said

    Do The Crime, Play The Fine..........Enough Said
  12. Replies
    3
    Views
    946

    Rest In Peace Kirby

    Rest In Peace Kirby
  13. Thread: Hoshi Ice

    by luvcldair
    Replies
    8
    Views
    869

    What about the float switch sticking, Since you...

    What about the float switch sticking, Since you said you had alot a calcium build up....maybe staying in freexe too long

    Just A Thought
  14. Replies
    14
    Views
    1,396

    They all will have there plus and minus's, I...

    They all will have there plus and minus's, I personally would worry more about the warranty you will get with the equiptment and the quailty of the install...If the guy took the time to do a Manual J...
  15. Replies
    4
    Views
    2,247

    This is the only thing i could find .....hope it...

    This is the only thing i could find .....hope it helps





    http://www.sheetmetalequip.com/usedequip/shopmaster.htm
  16. Replies
    12
    Views
    1,622

    Very Clean Install, Whch Type Of Bender Did You...

    Very Clean Install, Whch Type Of Bender Did You Use?
    Ive Been Thinking Of Getting The Imperial 7/8 Lever Type Bender
  17. Replies
    16
    Views
    2,330

    Most Txv's feed plus or minus 50% of rated tonnage

    Most Txv's feed plus or minus 50% of rated tonnage
  18. Replies
    8
    Views
    2,125

    Can you run the romex under the ducts?

    Can you run the romex under the ducts?
  19. Replies
    8
    Views
    2,125

    Not sure on your codes but I personally wouldnt,...

    Not sure on your codes but I personally wouldnt, I would run them over and crossing the ducts with using the romex staples...Plus it will look better
  20. Replies
    11
    Views
    1,883

    Looks Very COLD there, but nice work and clean...

    Looks Very COLD there, but nice work and clean install
  21. Thread: new to site

    by luvcldair
    Replies
    26
    Views
    1,354

    Welcome aboard

    Welcome aboard
  22. Replies
    106
    Views
    5,028

    Im 35 and started doing installs at 17 then got...

    Im 35 and started doing installs at 17 then got into maintenanceat 19 then service from there on...mostly refrigeration, larger systems and racks...now attempting to get my lisence and do my own thing
  23. Replies
    26
    Views
    2,840

    Liquid lime a way on stainless evap i/m's

    Liquid lime a way on stainless evap i/m's
  24. Replies
    17
    Views
    1,895

    I would say moisture or non condensables

    I would say moisture or non condensables
  25. Just my openion but i dont like the freon line...

    Just my openion but i dont like the freon line going into the evap, there not straight, I would put in a trap or a secondary drain, why the gap under your pad,and what is the wire running across your...
  26. Replies
    13
    Views
    1,074

    Personally I wouldnt use the old duct work from...

    Personally I wouldnt use the old duct work from the evap system, if you are paying for a cmplete install, i would expect a new complete install..Furthermore I would get atleast a 12 seer and not even...
  27. Replies
    18
    Views
    3,303

    Not sure what exactly you are trying to due or...

    Not sure what exactly you are trying to due or why?
    But the only thing i have come across out here in Calif are ball valves that shut off in the event of an earth quake, or violent shaking. but they...
  28. Replies
    17
    Views
    1,169

    Well said..........

    Well said..........
  29. Replies
    38
    Views
    6,747

    Very clean install, Good job

    Very clean install, Good job
  30. Replies
    17
    Views
    1,169

    They will want to put the time and $$$$ into it...

    They will want to put the time and $$$$ into it once the compressor take a crap...be sure to let them know it will void warranty of the problem isnt resolved if the compressor does go bad...

    But...
  31. Replies
    9
    Views
    871

    There are alot openions on this i see, So I guess...

    There are alot openions on this i see, So I guess Ill ad mine. I wouldnt do it even tho ive seen it done n short runs i think its best to add txv and reciever..Not to mention it gunna be alot of work...
  32. Replies
    12
    Views
    1,418

    That was my point and that they had primary and...

    That was my point and that they had primary and secondary reversed
  33. Replies
    12
    Views
    1,418

    The 90 was facing up and there wasnt much or...

    The 90 was facing up and there wasnt much or enough fall...When we replaced it we lifted the furnace and coil up and got more fall..Then replaced the drains with new

    Probably would have been...
  34. I think the reason they put they unit close to...

    I think the reason they put they unit close to the stairs is because they want the fku gas to be a footwarmer during the cold months
  35. Replies
    12
    Views
    1,418

    Got this call from a friend of mine that just...

    Got this call from a friend of mine that just bought a house in an upscale area. He said that there was orange rust running dwn the side of his house, from the 2nd floor to the 1st floor..

    Got up...
  36. Replies
    24
    Views
    2,522

    Just my openion, a while back I work for a shop...

    Just my openion, a while back I work for a shop that leases alot of I/M's. We did alot of rebuilds on them and if you had done them before it was a good thing and not bad on costs....Better than a...
  37. Replies
    9
    Views
    1,756

    Very Clean , Good Job Man

    Very Clean , Good Job Man
  38. Replies
    9
    Views
    1,841

    Gas flexs are ok to use out here in calif,(i...

    Gas flexs are ok to use out here in calif,(i think it may be the earthquake factor) but those photos are just a hack at work..I like the rips in the armaflex the best
  39. Replies
    8
    Views
    774

    For my years in the trade, i gave up a long time...

    For my years in the trade, i gave up a long time a go to try to fix leaks in evap coils cause from fod products,ect..

    I cant tell you how many i tried to fix, thought it was good then had to go...
  40. Replies
    15
    Views
    2,886

    Refrigeration men cool every hott box........

    Refrigeration men cool every hott box........
  41. Replies
    8
    Views
    9,113

    We always charge them in the cool mode, or weigh...

    We always charge them in the cool mode, or weigh it in of course...But living in So Calif we dont get very cold very often...
  42. Replies
    9
    Views
    2,578

    What kind are they?

    What kind are they?
  43. Replies
    9
    Views
    3,937

    Thats a sure fore way to kill a compressor

    Thats a sure fore way to kill a compressor
  44. Replies
    4
    Views
    2,163

    Go To Los Angeles and you will find them on roofs...

    Go To Los Angeles and you will find them on roofs with them in rott iron cages with pad locks and then lagged down to the roof.

    I guess people were going on the roog blowing the gas and taking the...
  45. Thread: Access...

    by luvcldair
    Replies
    8
    Views
    2,014

    I would take a photo with a tme stamp and let the...

    I would take a photo with a tme stamp and let the homeowner know that if there are any warranty issues with the unit and they are blocking acess to it that they will be billed the (EXTRA) labor that...
  46. Replies
    5
    Views
    2,568

    Simply .......wow

    Simply .......wow
  47. Replies
    15
    Views
    3,166

    Very Impressive, Good Job.........

    Very Impressive, Good Job.........
  48. Replies
    4
    Views
    859

    Anyone know of a link to the american standard...

    Anyone know of a link to the american standard website for manuals on residentual Condensing units...

    Thanks For All The Help
  49. Replies
    17
    Views
    3,230

    Thats scary

    Thats scary
  50. Replies
    11
    Views
    855

    Speak for yourself i dont do slicers yet ....lol