10-24-2011, 03:08 PM
Thread: help with Honeywell TrueIAQ
by net_tech- Replies
- 4
- Views
- 733
No, I am not a pro, but got it installed and...
No, I am not a pro, but got it installed and working. The quotes I got for the installation from the PROs were jaw dropping, so I decided to do it myself. Just could not see spending over a $ for the...
-
10-19-2011, 01:28 PM
Thread: help with Honeywell TrueIAQ
by net_tech- Replies
- 4
- Views
- 733
help with Honeywell TrueIAQ
I want to replace a manual honeywell humidistat with a digital TrueIAQ model, and looking for some help with wiring.
Carrier furnace - 58MCB120-10120 has the following terminals:
===
G
COMM... -
10-17-2011, 08:52 AM
Thread: Pros - what filters do you use?
by net_tech- Replies
- 23
- Views
- 1,337
View Post
1” Polarized-Media Electronic Air Cleaners (http://www.dynamicaqs.com/air-cleaners/)
Combining ease of installation with low static pressure (for lower energy consumption and system wear), 1”... -
10-15-2011, 09:26 PM
Thread: Honeywell HE300 & DG115EZIAQ
by net_tech- Replies
- 0
- Views
- 794
Honeywell HE300 & DG115EZIAQ
I have a Honeywell HE300A1005 humidifier with a basic H8908 humidistat. I was wondering if I can switch my humidistat with a more advanced model DG115EZIAQ?
Mainly want to get the automatic... -
12-16-2010, 09:46 PM
Thread: Carrier HVAC short cycle question
by net_tech- Replies
- 7
- Views
- 751
this is a 2 stage furnace 58cva070-12, but wired...
this is a 2 stage furnace 58cva070-12, but wired as a single stage (according to the installer this is the default factory setting and is more efficient)
the house is 1680sq ft with two exterior... -
12-15-2010, 05:00 PM
Thread: Carrier HVAC short cycle question
by net_tech- Replies
- 7
- Views
- 751
it looks like i am only getting 1 cycle per hour...
it looks like i am only getting 1 cycle per hour (15 - 20 min of run time and 40-45 min resting)
-
12-15-2010, 03:06 PM
Thread: Carrier HVAC short cycle question
by net_tech- Replies
- 7
- Views
- 751
Carrier HVAC short cycle question
I have a newly installed HVAC (Carrier) and was wondering if 20min of run time is considered a short cycle for the furnace?
Thanks
See my log below
http://remontnetworks.com/log.jpg -
08-23-2010, 04:49 PM
- Replies
- 2
- Views
- 527
I need to get kW/h for my AC system to enter in...
I need to get kW/h for my AC system to enter in to my thermostat. (baycontrols)
With the existing value (3.432kW/h)and electricity rate of $0.15 it shows, that it costs me $4-$5 a day to run the... -
08-20-2010, 10:20 AM
- Replies
- 2
- Views
- 527
help calculating Cooling Rate (Units/Hour)
Rate = Voltage * Current / 1000
Example:
•With the A/C system running, the voltage is 223 VAC and the current is 21.3 Amps, the Cooling Rate is 4.75
Can someone tell me what voltage and... -
07-12-2010, 08:49 PM
Thread: air filter inside the return
by net_tech- Replies
- 5
- Views
- 475
will post a picture so you guys can criticize....
will post a picture so you guys can criticize. It’s hard to explain using word
-
07-12-2010, 06:51 PM
Thread: air filter inside the return
by net_tech- Replies
- 5
- Views
- 475
thanks for your quick responses
thanks for your quick responses
-
07-12-2010, 03:30 PM
Thread: air filter inside the return
by net_tech- Replies
- 5
- Views
- 475
air filter inside the return
Several years ago I had my HVAC system replaced and a contractor decided to make a custom (diagonal) opening in the return, right before it enters the system cabinet, so I can slide in air filters...
-
07-09-2010, 02:01 PM
Thread: evaparator coil question
by net_tech- Replies
- 2
- Views
- 375
Got it. Will stay away from ASPEN Can you tell...
Got it. Will stay away from ASPEN
Can you tell if this system would qualify for a gov. rebate?
Outdoor - 4TTB4030
Coil - 4TXCB05
Indoor - TUD080R9V4K
There is also a possible rebate ($300)... -
07-09-2010, 11:38 AM
Thread: Carrier Rebates
by net_tech- Replies
- 2
- Views
- 327
I would think so. Just got a quote on a Carrier...
I would think so. Just got a quote on a Carrier system with $100 rebate from Carrier, $300 from PECO and $1500 Gov.
-
07-09-2010, 09:16 AM
Thread: evaparator coil question
by net_tech- Replies
- 2
- Views
- 375
evaparator coil question
Can someone post or point me to the tech spec of 2 coils listed below?
Aspen - 36D44+TDR / Trane - 4TXC037
Would you go with Aspen over Trane?
Thanks -
07-08-2010, 09:46 PM
Thread: Replace or Repair
by net_tech- Replies
- 12
- Views
- 1,116
View Post
I didn’t know what the designed temperature was 85. I also didn’t know that you can’t get more than 20 degree difference in 100° heat. Yeah today it’s back at 72° inside with 90° outside.
I am... -
07-08-2010, 09:02 PM
Thread: Replace or Repair
by net_tech- Replies
- 12
- Views
- 1,116
System 1 - Carrier Outdoor - 24ABC630 Coil -...
System 1 - Carrier
Outdoor - 24ABC630
Coil - CNPVP4217
Indoor - 58CVA090-16
System 2 - Trane
Outdoor - 4TTB4030
Coil - 4TXCB05
Indoor - TUD080R9V4K -
07-08-2010, 02:15 PM
Thread: Replace or Repair
by net_tech- Replies
- 12
- Views
- 1,116
I also got a quote on Trane and still waiting on...
I also got a quote on Trane and still waiting on Carrier.
I saw a lot of posts saying you can have the best system in the world, but if you have a crappy install, you system will be junk.
Let's... -
07-08-2010, 02:08 PM
Thread: Replace or Repair
by net_tech- Replies
- 12
- Views
- 1,116
I will try to answer everything I can. what...
I will try to answer everything I can.
what kind of insulation do you have?
this is a townhouse so I technically have 2 exterior walls and 10 windows. The house is 14 years old, so whatever... -
07-07-2010, 03:09 PM
Thread: network thermostat
by net_tech- Replies
- 7
- Views
- 1,129
Found 2 more myself. Intwine Energy IECT-210...
Found 2 more myself.
Intwine Energy IECT-210 Wi-Fi Communicating Thermostat
Bay Controls BW-WT2-BG BAYweb Advanced Internet Thermostat
Is there anything else? -
07-07-2010, 02:51 PM
Thread: network thermostat
by net_tech- Replies
- 7
- Views
- 1,129
network thermostat
As I mentioned in my previous post, I may end up replacing my existing HVAC system. So I am wondering if there is a thermostat I can connect to my PoE network switch and get the ability to control...
-
07-07-2010, 02:32 PM
Thread: Replace or Repair
by net_tech- Replies
- 12
- Views
- 1,116
Got a quote on a XC14-03-230-03 system, which I...
Got a quote on a XC14-03-230-03 system, which I was told can bing a house my size down to 72° in a 100° heat.
-
07-07-2010, 09:22 AM
Thread: Replace or Repair
by net_tech- Replies
- 12
- Views
- 1,116
a contractor came out and said that my AC can't...
a contractor came out and said that my AC can't handle a 100° heat, 76° is the best i can get out of my unit in a 1,676 sq ft house.
here is a pic of the outside unit
... -
07-06-2010, 12:57 PM
Thread: Replace or Repair
by net_tech- Replies
- 12
- Views
- 1,116
Replace or Repair
My current AC system (Carrier 15 years old) is about to give up on me. Yesterday it worked all day non-stop, but could not bring the temperature below 76°. I checked temperature at the return and...