Search:

Type: Posts; User: control distributor

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Thank you for the reply. The problem is they are...

    Thank you for the reply. The problem is they are 6 weeks out.
  2. WBT900

    We need a WBT900. The factory has a 5 week back order. Do you have any spares to sell?
  3. Replies
    23
    Views
    6,552

    Time to upgrade. Part number MW-MTOOL-6 find a...

    Time to upgrade. Part number MW-MTOOL-6 find a JCI ABCS (try M&M in VA) the upgrade is not as expensive as the initial purchase price.
  4. Replies
    23
    Views
    6,552

    The HVACpro soft ware can be reloaded on Win8.1. ...

    The HVACpro soft ware can be reloaded on Win8.1. If you have an XP disk go to a windows store (if available in your area) and they can load just what you need to run HVACpro.

    We use the S...
  5. Replies
    21
    Views
    7,559

    GCM driver

    We now use a Niagara AX driver made by www.csicubed.com
  6. Replies
    0
    Views
    407

    Richards-Zeta

    Looking to buy new/used VAV box controllers.
  7. Replies
    2
    Views
    548

    Upgrade to Iconics FacilityWorx

    Upgrade to Iconics FacilityWorx
  8. FEC vs. FX-PC

    We are now selling FX-PC. We don't have the UL smoke rating that many of the branch products have. Our FX60 front-end now is ARRA compliant.
  9. Replies
    3
    Views
    917

    I agree with NewportNic

    I agree with NewportNic
  10. Replies
    4
    Views
    657

    Check out Honeywell's HVI. I think it sould work...

    Check out Honeywell's HVI. I think it sould work in the daily on/off mode.
    http://customer.honeywell.com/techlit/pdf/69-0000s/69-2316EFS.pdf
  11. Replies
    149
    Views
    21,409

    No kool-aid here my friend. If JCI, HNY,...

    No kool-aid here my friend. If JCI, HNY, Siemens, ect.. want to put a FREE Sedona chip in their control, they can. How sweet would it be if your library of applications was all written in Sedona...
  12. Replies
    149
    Views
    21,409

    Sedona is the natural evolution toward true...

    Sedona is the natural evolution toward true openness. The Sedona framework is free and open. You can write an application with Sedona and download it into brand A's controller. You can take that...
  13. Replies
    149
    Views
    21,409

    I will send you an email.

    I will send you an email.
  14. Replies
    36
    Views
    6,585

    Also known as "bit flips." When the conversion...

    Also known as "bit flips." When the conversion is taking place the binary code occasionally flips a 0 for a 1, or a 0 for a 1. This will cause the program to lock up. Not a big deal, if you are...
  15. Replies
    11
    Views
    1,767

    The server is in a safe place and costs $$$. ...

    The server is in a safe place and costs $$$. TheXXXXXXX comparison was referring to the wall stats.
  16. Replies
    11
    Views
    1,767

    I have heard from schools that are unhappy with...

    I have heard from schools that are unhappy with Cypress.
    The main two reasons are/were cypress needs a stand-alone server before any integration can be done & that when kids knock them off the walls...
  17. Replies
    8
    Views
    1,750

    FYI- This is JCI's official stance on Win7 "To...

    FYI- This is JCI's official stance on Win7

    "To run HVACPro in WIN 7 you will need to install it in virtual WinXP environment."
  18. Replies
    8
    Views
    847

    Try Triacta http://www.triacta.com/

    Try Triacta

    http://www.triacta.com/
  19. Replies
    36
    Views
    6,585

    data flips

    Kevin,
    We use the Contemporary Controls BACnet router (JCI’s is the same thing with a different part#). Be aware and prepared for data flip.
  20. Replies
    19
    Views
    4,031

    The VMAs count as 2.3 devices. I suggest you...

    The VMAs count as 2.3 devices. I suggest you break up the bus, if possible.
  21. Ask Sam ...

    Ask Sam http://hvac-talk.com/vbb/member.php?u=32606
    His stuff should do it. We use his peripherals to diagnose the N2 bus.
  22. Replies
    7
    Views
    1,534

    there are a variety of AI to DO sequencer boards...

    there are a variety of AI to DO sequencer boards on the market. For $50 you should be able to get 4 solid state relays that can be energized by the desired AO voltage.
  23. Replies
    6
    Views
    1,069

    We are JCI distributors in the North East. If...

    We are JCI distributors in the North East. If the problem continues we will help you try to warranty it. The control carries a three year warranty. Now that the N30s are obsolete the warranty...
  24. Replies
    5
    Views
    643

    Try cleaning out your PCs temporary internet...

    Try cleaning out your PCs temporary internet files.
    Free up some RAM in the FX40 by deleating trends and unused points.
  25. Check out ICMs Simple Comfort line. They are...

    Check out ICMs Simple Comfort line. They are made in the USA!
  26. The official word from JCI is that they do not...

    The official word from JCI is that they do not support running HVACpro on Windows 7's XP mode. That said they do report that they are told it work. We have been sucessful with it.
  27. Replies
    5
    Views
    643

    If the FX40 is less than 3 years old, make a deal...

    If the FX40 is less than 3 years old, make a deal with the installer to return it under warranty and use an FX60.
  28. Replies
    11
    Views
    1,055

    Herman, I appreciate your comments. I am not...

    Herman,
    I appreciate your comments. I am not trying to be deceptive; my name is "Control Distributor" it should be pretty clear that I sell controls. Most likely if you buy FacilityWorx we will...
  29. Replies
    11
    Views
    1,055

    We sell Facility Worx. We love it! I do talk...

    We sell Facility Worx. We love it! I do talk about it b/c there is finally an affordable upgrade. We are running into jobsites that were forced to rip out and replace entire systems b/c JCI told...
  30. Replies
    8
    Views
    1,655

    Here is Siemens chart

    Here is Siemens chart
  31. Replies
    11
    Views
    1,055

    M3 has become obsolete. Fortunately for you the...

    M3 has become obsolete. Fortunately for you the company who developed the product is still selling it. If you choose to upgrade your M3 the process is painless. To learn more go to...
  32. Replies
    3
    Views
    1,158

    I am staying up late tonight trying to find a...

    I am staying up late tonight trying to find a deal on ski boots. Whats wrong with me?
  33. Replies
    0
    Views
    389

    Sedona Control $300

    reply if you want details
  34. Replies
    1
    Views
    1,319

    sold

    sold
  35. Replies
    4
    Views
    2,089

    I can help, if you are still stuck.

    I can help, if you are still stuck.
  36. Replies
    3
    Views
    1,158

    My buddy is a Novar guy. Email me and I'll hook...

    My buddy is a Novar guy. Email me and I'll hook you two up.
  37. This is what the JCI branches use to go from USB...

    This is what the JCI branches use to go from USB to N2

    http://www.interstatecontrols.com/featured_product/downloads/S2USB485%20Technical%20Summary%20Rev%201_5.pdf
  38. Replies
    11
    Views
    1,055

    The N30s are really fussy. We offer for our...

    The N30s are really fussy. We offer for our customers them to watch us plug-in to them. Cover your butt, and warn the customer before you touch any of them. They are obsolete, however many...
  39. Replies
    19
    Views
    3,608

    Hungry Tech, Are you in Colorado? I think we...

    Hungry Tech,
    Are you in Colorado? I think we spoke on the phone.

    Whats up Joey :)
  40. Replies
    4
    Views
    907

    Denise Richards I/Os have been used up.

    Denise Richards I/Os have been used up.
  41. Replies
    15
    Views
    2,577

    I agree with Super Duper Tech. When the NCM...

    I agree with Super Duper Tech. When the NCM fails the FX60 is the easiest replacement. It speaks N2 flawlessly and it can export data via BACnet, Lon, or Fox protocol.
  42. Replies
    15
    Views
    2,577

    What makes these jobs tricky is that the NCMs...

    What makes these jobs tricky is that the NCMs talk on an N1 bus. The N1 bus can be Arcnet or wired differently. The most common problem people have is that when one NCM fails there is not a good...
  43. Replies
    15
    Views
    2,577

    I will expand on the FacilityWorx solution. This...

    I will expand on the FacilityWorx solution. This software is a direct, updated version of Johnson's M3 or M5. It will automatically suck up the old data and spit out the same graphics with very...
  44. Replies
    1
    Views
    1,319

    Novar VAV-4020

    3) VAV-4020 w/ connector. We want to get these off the shelf. Please make an offer. Also have 2) WTS-10 sensors
  45. Replies
    3
    Views
    627

    Just so you know there is a software upgrade for...

    Just so you know there is a software upgrade for PMI. Check out FacilityWorx by Iconics.
  46. Replies
    15
    Views
    2,577

    The JCI software can be upgraded and used on a...

    The JCI software can be upgraded and used on a new Windows 7 PC. The software is called FacilityWorx and it is sold by Linda Perez at Iconics in Foxboro, MA.
  47. Replies
    4
    Views
    907

    You mention a hand held tool. Are you working on...

    You mention a hand held tool. Are you working on the RZ-VAVs. If so the mstat is really all you need.
  48. Replies
    149
    Views
    21,409

    We have been playing with a Sedona control and we...

    We have been playing with a Sedona control and we really like it. It programs easily & the cost is 1/2 of a JCI equal. I'll send you a spec sheet if you are curious.
  49. Replies
    4
    Views
    950

    We do have some software. I could not find your...

    We do have some software. I could not find your email address. Send me a note.

    Jeff@InterstateControls.com
  50. Replies
    77
    Views
    12,648

    Steve, Send me an email tomorrow-...

    Steve,
    Send me an email tomorrow- jeff@interstatecontrols.com
Results 1 to 50 of 139