Search:

Type: Posts; User: bmc

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    32
    Views
    2,158

    Valve plate, had that very same situation two...

    Valve plate, had that very same situation two summers ago. Cylinder walls were untouched however pistons and valve plates had pieces of broken valves stuck into them. Put new plates, valves and...
  2. Replies
    14
    Views
    3,733

    4 flashes on the indoor unit means "outdoor...

    4 flashes on the indoor unit means "outdoor communication error(forward transfer signal error)" This error comes from a bad indoor board in my experience.
  3. Replies
    12
    Views
    4,793

    Wow this is an old thread brought back to...

    Wow this is an old thread brought back to life......anyways for anyone who's interested I have the Goodway one in the picture for several years now and it is not very powerful. You will not be happy...
  4. Replies
    16
    Views
    1,374

    Just for discussion purposes if you wanted a...

    Just for discussion purposes if you wanted a reliable, cost effective method of staging several units with a single controller check out honeywells line of T775 controllers I have used them in...
  5. Replies
    1
    Views
    428

    Some manufacturers not ready for 2010

    Tried to get prices and delivery dates for some upcoming 30 ton 2-circuit splits I need to change out. Trane and York told me they did not have them available in these configurations this year in...
  6. Replies
    4
    Views
    1,285

    SCR control works very well on older VAV boxes....

    SCR control works very well on older VAV boxes. In one site I do repairs at have found only draw back is expensive to replace the SCR components when they fail.
  7. Thread: Aaon coil leaks

    by bmc
    Replies
    24
    Views
    4,360

    I repaired a leak this past summer on an 4 year...

    I repaired a leak this past summer on an 4 year old 10-ton AAON unit. Leak was from a hairline crack on a 3/8" tubing line for HGB. Seems the quality of copper tubing is not up to par on these units.
  8. Replies
    12
    Views
    954

    I wouldn't buy either one, I'd invest in a Testo...

    I wouldn't buy either one, I'd invest in a Testo 330. That's what I have, best I've had yet by far. Just my opinion.
  9. Replies
    28
    Views
    1,801

    I've got a LockFormer. They are in my opinion the...

    I've got a LockFormer. They are in my opinion the most reliable. Cost doesn't matter to me as much when it lasts forever.
  10. Thread: RSES Members

    by bmc
    Replies
    27
    Views
    2,607

    New member this year..... magazine is pretty...

    New member this year..... magazine is pretty good, just recently purchased RSES training manual #3, good reading.
  11. Replies
    8
    Views
    652

    Sweet, I was having issues as well, that works...

    Sweet, I was having issues as well, that works for me too.
  12. Thread: ACR smartbutton

    by bmc
    Replies
    2
    Views
    522

    Ah no, don't think so. Could use one of those in...

    Ah no, don't think so. Could use one of those in my tool pouch though.
  13. Thread: ACR smartbutton

    by bmc
    Replies
    2
    Views
    522

    ACR smartbutton

    Anybody heard of or used one of these ACR smartbutton data loggers? They seem like a pretty good idea if they do what they claim. Any good?

    http://www.acrsystems.com/products/smartbutton
  14. Replies
    117
    Views
    8,058

    Oh my, I'm glad you're working with a journeyman....

    Oh my, I'm glad you're working with a journeyman. Seriously though, find a good picture of the basic refrigeration cycle and it will explain it to you. I'm sure somebody could provide you with a link...
  15. Thread: Nice & Straight

    by bmc
    Replies
    34
    Views
    5,047

    I'll see if I can dig up some of my job pics.

    I'll see if I can dig up some of my job pics.
  16. Thread: Nice & Straight

    by bmc
    Replies
    34
    Views
    5,047

    Nice job, if you want to improve on future...

    Nice job, if you want to improve on future installs use some curved reducers next time.
  17. Replies
    2
    Views
    493

    Rule of thumb is minimum 4 to 1 for proper...

    Rule of thumb is minimum 4 to 1 for proper airflow.
  18. Replies
    15
    Views
    1,204

    What about the Supco TA3, digital display,...

    What about the Supco TA3, digital display, audible alarm, extendable sensor up to 2000 feet. I've got a similar project underway to monitor 6-8 walk-in boxes and these are what I'm leaning towards...
  19. Replies
    61
    Views
    4,812

    Changed companies and was supplied with a...

    Changed companies and was supplied with a tek-mate now for about a year so far it's been great, always found the leak. Seems to be the best one I've used so far in it's price range. No complaints yet.
  20. Thread: WOP Worthy?

    by bmc
    Replies
    9
    Views
    1,903

    Sweet looking, installing late model Trans Am...

    Sweet looking, installing late model Trans Am seats in an 89 camaro!
  21. Thread: woodsball

    by bmc
    Replies
    6
    Views
    320

    Yes, great summertime stress reliever.

    Yes, great summertime stress reliever.
  22. Replies
    8
    Views
    1,266

    Do not increase manifold gas pressure from...

    Do not increase manifold gas pressure from manufacturers specs, check your meter clocking results again and verify them accurate. Size and count orfices again, seems like that's where your problem is.
  23. Replies
    88
    Views
    4,225

    -30 Celcius here, gas meter dials spinning round...

    -30 Celcius here, gas meter dials spinning round and round.
  24. Thread: Heil furnace age

    by bmc
    Replies
    1
    Views
    2,261

    Heil furnace age

    Did friend a favor tonite and inspected gas furnace in a house my buddy's about to purchase, wondering what age the furnace is.

    Heil Ultimate II mid-efficient
    Model# NUG5075BFB1
    Serial# ...
  25. Replies
    2
    Views
    496

    Thanks for the link mckim, good info there. I...

    Thanks for the link mckim, good info there. I also just realized I posted this in the wrong section by mistake, should be in commercial HVAC. Oh well.
Results 1 to 25 of 94
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event