  1. For the same reason they didn't upgrade the...

    For the same reason they didn't upgrade the thermostat I'm guessing;)
  2. There are more than one way to identify the...

    There are more than one way to identify the guilty component. If his detector fails he can try dye in the system. The 3 manufacturers that I deal with say that this will not impact on warranties....
  3. The outdoor sensor is supposed to be run with an...

    The outdoor sensor is supposed to be run with an independent 2 conductor wire. Most contractors cheap out and use a multi conductor cable to do all of the functions of the outdoor section of the heat...
  4. Not for naught. You have grasped the concepts of...

    Not for naught. You have grasped the concepts of what should be. Now communicate with the powers that be at the company that sold your system to you. Some companies might consider you a pain in the...
  5. The 10/10/10 guy would have my attention for...

    The 10/10/10 guy would have my attention for sure, and I don't see your prices because they have magically disappeared as well they should have, we have great moderators who take that stuff...
  6. Replies
    15
    Views
    576

    We don't talk prices here, they fluctuate greatly...

    We don't talk prices here, they fluctuate greatly depending on market location. He's in the ball park for our location. As far as brand, not as important as how it's installed. I deal with Luxaire...
  7. It will.

    It will.
  8. Replies
    16
    Views
    924

    Fail. Would never pass inspection here for sure.

    Fail. Would never pass inspection here for sure.
  9. The flex needs to be fully extended to obtain the...

    The flex needs to be fully extended to obtain the listed air flow. Your return is undersized.
  10. What brand and model thermostat do you have?

    What brand and model thermostat do you have?
  11. I think that is an ICP product number it would be...

    I think that is an ICP product number it would be 3.5 ton capacity. Most likely will work with a 410a unit with a metering device change and a good flushing. You will need a competent HVAC company to...
  12. Replies
    34
    Views
    1,084

    I am aware of those issues but the problem is...

    I am aware of those issues but the problem is what the tech is telling the OP or more to the point, trying to sell to him.
  13. Replies
    34
    Views
    1,084

    Sounds like your tech is not all that confident...

    Sounds like your tech is not all that confident with his abilities to replace a compressor properly. Telling you that his work will fail in short order would scare me off. The warranty on the unit is...
  14. Stop with the factory tech said. If he did, he's...

    Stop with the factory tech said. If he did, he's an idiot. That stat will only work with a duel fuel set up when combined with the outdoor sensor and programmed to do so. You could upgrade and go...
  15. Replies
    14
    Views
    914

    York used to, those stupid blue Mexican coils...

    York used to, those stupid blue Mexican coils ended that:)
  16. Replies
    14
    Views
    914

    Luxaire/York for one.

    Luxaire/York for one.
  17. Replies
    45
    Views
    2,125

    Your call. Just because a company does all the...

    Your call. Just because a company does all the "right" things doesn't mean they do the right things right. Sounds like an old school guy who doesn't keep up with changes in the industry but he may be...
  18. Never had any problems with them.

    Never had any problems with them.
  19. Replies
    14
    Views
    498

    First off, we don't normally recommend using...

    First off, we don't normally recommend using night time set back on a heat pump, especially if you don't want your aux heat to stage on to help recover. Secondly, I suspect you have reached the...
  20. A BTU is a BTU. New or old, single, two stage or...

    A BTU is a BTU. New or old, single, two stage or mod. The actual output needs to be verified. As far as actual sizing, I would expect under normal conditions the first stage would be more than...
  21. Replies
    12
    Views
    358

    Well, after all, it's not rocket science. I...

    Well, after all, it's not rocket science. I appreciate your observations and understand the logic from your prospective. I do however find faults in some of your rationals. You are correct on one...
  22. Kinda thought that:)

    Kinda thought that:)
  23. Needs pre-charged pressure equal to the cold fill...

    Needs pre-charged pressure equal to the cold fill pressure of the reducing valve, 12-15psi. And I agree, better to call a hydronics contractor to check it out. If the boiler itself has a small leak,...
  24. Replies
    16
    Views
    575

    That'd be like putting radiator sealer in your...

    That'd be like putting radiator sealer in your new Beamer.
  25. Replies
    17
    Views
    647

    The hanger strap is visible in the first picture...

    The hanger strap is visible in the first picture and it looks like it's been cut