    I think the managers I laugh at the most... and...

    I think the managers I laugh at the most... and can be the most frustrating are the ones that "could do your job if they had the tools". I asked one why he was a grocery manager then. He didn't...
  2. Replies
    32
    Views
    1,017

    I use low loss on everything except evacuation...

    I use low loss on everything except evacuation and when charging racks. Refrigerant loss comes from the hoses, depending on the length of the hose it can have several ounces of refrigerant in them...
  3. Replies
    6
    Views
    366

    Shame this is in an open Forum... Why do...

    Shame this is in an open Forum...

    Why do think they are flooding back?

    WM is a beast all it's own the way they run things...
  4. Replies
    3
    Views
    352

    DREWBLUE, I have a source for Spectrum and Lingo....

    DREWBLUE, I have a source for Spectrum and Lingo. Email me.

    It is all Refurb, but have never had a problem with their stuff.
  5. Replies
    45
    Views
    3,900

    I used to use a Dial a Charge until I dropped it...

    I used to use a Dial a Charge until I dropped it :(

    But have been successful with putting a stubby hose with ball valve on the condenser, purging to the ball valve with vapor, then opening the...
  6. Replies
    54
    Views
    1,485

    Finding one would not be a problem, but after...

    Finding one would not be a problem, but after looking at what I personally could get and costs... (The Supco makes them that go to 240v, but a max of 10 mins On Delay), Might as well use the Paragon...
  7. Replies
    54
    Views
    1,485

    My diagram was for an all 240v system. ...

    My diagram was for an all 240v system. Contactor, RV, Switching relay and DOM are all 240 coils. (This is based on the "Fact" that was stated there is not 24v at the condenser) Most Heat Pumps check...
  8. Replies
    54
    Views
    1,485

    .

    .
  9. Replies
    54
    Views
    1,485

    Ok, the reversing valve energized is cool. ...

    Ok, the reversing valve energized is cool.

    This is assuming at the condenser, you have the following for the control circuit...

    240v common
    "Y" to bring compressor on
    "B" to energize the...
  10. We have a supplier here that sells the...

    We have a supplier here that sells the replacement baskets made of metal that work in most applications, and the motor can be changed later, but if the fan plenum is shallow, they do not work well.
  11. Yup. I usually roll about 4 together and put 2...

    Yup. I usually roll about 4 together and put 2 of the rolls in a shell. Wait a few hours or when you see a significant pressure drop. It is amazing the amount of moisture those things will absorb...
  12. Anyone used "sanitary napkins" for moisture...

    Anyone used "sanitary napkins" for moisture remove besides me?
  13. I just went through the same thing. Had the oil...

    I just went through the same thing. Had the oil in 2 Racks I was having issues with analyzed and the moisture content on both was well below 50ppm, within specs duPont said was "acceptable". I...
  14. Replies
    46
    Views
    2,696

    I have only worked on one cascade system down to...

    I have only worked on one cascade system down to -40 for a pharmaceutical manufacturer. Have always wanted to get more into it.
  15. Replies
    7
    Views
    304

    Ok, so I AssU-MeD that "freezing up" meant not...

    Ok, so I AssU-MeD that "freezing up" meant not harvesting, my bad. But if he does what he posed to does and begins and the beginning with the proper informations in his hand he mights can figger it...
  16. Replies
    9
    Views
    1,071

    Shhh... Don't tell him about the digital...

    Shhh... Don't tell him about the digital combiners.. :eek:
  17. Replies
    7
    Views
    304

    X2 "Freezing up" is a symptom of another...

    X2

    "Freezing up" is a symptom of another problem. Clear the ice, start the machine, and watch the seq of operation compared to the manufactures specs. Most Ice Machine manufactures publish the...
  18. Replies
    46
    Views
    2,696

    I have been in the HVAC-R industry for almost 21...

    I have been in the HVAC-R industry for almost 21 years. I actually started out as a helper for a guy that did mostly HAC installs in mobile/modular housing, but ONLY after the power was turned on...
  19. Replies
    21
    Views
    981

    This one was leaking so bad it would have flooded...

    This one was leaking so bad it would have flooded the compressor with liquid lol.


    Sent from my SCH-I605 using Tapatalk
  20. Replies
    21
    Views
    981

    This unit has 2 condenser fans. Factory setup. ...

    This unit has 2 condenser fans. Factory setup. The fan cycling cuts the fan farthest from the header off first.. then the headmaster kicks in if then pressure continues to drop. Its in the...
  21. Replies
    21
    Views
    981

    Headmasters....

    Interesting

    I have been in the business almost 20 years.

    When it comes to headmasters, If they fail, I always bypass them by removing the convenient little charging tube and temporarily...
  22. Replies
    3
    Views
    352

    Looking for a sales position? Except for Resi...

    Looking for a sales position? Except for Resi work, I do not know many contractors out here that use dedicated sales.
  23. And he found it.. Lol. Now, the question is.....

    And he found it.. Lol. Now, the question is.. does he regret it?!

    Sent from my SCH-I605 using Tapatalk
  24. Replies
    16
    Views
    2,478

    Ok. So I have seen the pic. Read all the...

    Ok.

    So I have seen the pic.

    Read all the replies.

    and am still laughing.

    Did i not see on of the ductopus lines go fro supply to return in there somewhere??
  25. Replies
    56
    Views
    10,259

    Man this reminds me why I don't do resi work...

    Man this reminds me why I don't do resi work anymore..


    Many.

    Many.

    Many years ago when I started as a helper for a guy that did installs in "Manufactured Housing"... I did an install in...