  1. Why dont you just run the drain out above a...

    Why dont you just run the drain out above a window or near a porch and the unit will still run but the homeowner can call you to let you know they have a problem. but you dont have to rush it...
  2. Replies
    14
    Views
    465

    The reverse adapter is why I got the yj. We...

    The reverse adapter is why I got the yj. We broke the ratchet part the other day j mart replaced no questions asked.

    Sent from my C811 4G using Tapatalk
  3. Thread: I need more!!

    by klee7013
    Replies
    16
    Views
    639

    x2

    x2
  4. My bad I mixed it up. True suction went in a...

    My bad I mixed it up. True suction went in a vacuum. It may not have cut out on head pressure. Because it got metered when it left the indoor coil then metered again at the outdoor.

    My bad...
  5. But instead of subcooled liquid going to the txv...

    But instead of subcooled liquid going to the txv you have discharge straight from the compressor through the bigger copper line backing up. Thats what happened when one of our guys did it. To...
  6. Your correct it will pass through it but not...

    Your correct it will pass through it but not right.
    For example TXV backwards in the AH. When it goes into heat the TXV will meter it at the AH. And the unit will cut off on high pressure...
  7. It can be done i have seen it. We had a guy put...

    It can be done i have seen it. We had a guy put a new txv in the AH and installed new 410a condenser. Pulled a vacuum. It was calling for heat. And head went crazy and no pressure back on the...
  8. Replies
    22
    Views
    1,256

    You want a 70 to 75 suction pressure in the AC...

    You want a 70 to 75 suction pressure in the AC and your good.
  9. Thats because it doesnt have a screen on it....

    Thats because it doesnt have a screen on it. :grin2:

    Great work/
  10. Replies
    38
    Views
    1,404

    We are currently working on one with green oil. ...

    We are currently working on one with green oil.

    Old AH so we are installing a new air handler. But condenser is still under warranty. Called the manufacturer they recommended pulling compressor....
  11. Replies
    8
    Views
    399

    I have discussed this with a couple people that...

    I have discussed this with a couple people that do work in NC. Alot of people opinions it does not save money. Due to heat pump running continuously not able to satisfy the house vs heat strips...
  12. I meant titan my bad. Thanks for correcting me...

    I meant titan my bad. Thanks for correcting me Mike.


    Sent from my C811 4G using Tapatalk
  13. You want the YJ brute 4 valve manifold. I...

    You want the YJ brute 4 valve manifold.

    I bought mine used on ebay. and re calibrated the heads that came with it and put them on my digicool manifold.

    Good luck. I can post a picture tomorrow...
  14. We had one we repaired. Was not that bad turned...

    We had one we repaired. Was not that bad turned it on. Blew embers down into the ductboard trunk and caught on fire. Our guys left and got a call a few minutes later. We where right down the...
  15. Replies
    7
    Views
    417

    i broke two while checking a compressor to ground...

    i broke two while checking a compressor to ground on a top of a roof. Was pissed had to go buy a new set and broke one of the new ones.

    They dont like getting stepped on.
  16. Yeah try it right to a pump first and see if it...

    Yeah try it right to a pump first and see if it pulls down & if it does pull down. It is prolly what iceman stated.

    If it doesnt pull down then it may be the bluvac
  17. I bet the bluvac is going bad. We had two out of...

    I bet the bluvac is going bad. We had two out of seven do this and it was with the same tech. Think what caused it was tightening down the gauge by turning the micron gauge itself rather than...
  18. Replies
    27
    Views
    1,788

    How have you like the regulator? Has it held up...

    How have you like the regulator? Has it held up to normal use?
  19. Replies
    10
    Views
    868

    https://www.johnstonesupply.com/storefront/product...

    https://www.johnstonesupply.com/storefront/product-view.ep?pID=H27-718
  20. Replies
    21
    Views
    941

    sometimes you can find a lightly used set on...

    sometimes you can find a lightly used set on ebay.
    Hell i bought one that had good gauge heads and ball valve hoses for 120
    Switched my AK900 to the 4 valve and put the gauge heads on the DC...
  21. Take temperatures at the hot vapor line near...

    Take temperatures at the hot vapor line near king valve. Then take temperature right before indoor coil on the same line. If close to the same go to next step.
    Take temp of liquid line coming...
  22. Replies
    18
    Views
    1,208

    Did that still with a recovery tank still did...

    Did that still with a recovery tank still did not work correctly. How i found he was having trouble pulling a complete system i switched the micron gauges and it read instant difference.

    Not...
  23. Replies
    18
    Views
    1,208

    Yeah Joey i want to say thanks for the great...

    Yeah Joey i want to say thanks for the great product you have. We got 3 blue vacs for work and 5 UEi 100s. Love them.

    One guy seems to be messing his up. Had to replace it twice. It wont...
  24. Replies
    25
    Views
    1,403

    HVACTALK IS THE PROMO CODE. for 5 % i thinl...

    HVACTALK IS THE PROMO CODE. for 5 % i thinl
    Then sometimes if you make a large order they will give you a coupon for $20 off i think i cannot remember
  25. Thread: DIGI AK900

    by klee7013
    Replies
    44
    Views
    2,225

    I agree with you that they are becoming more...

    I agree with you that they are becoming more standard. I bought one before UEI and bought clamps then i bought a UEI set.

    But many people and i use to be one of them that think of UEI as...