Trans TXV
This is the third time recently that I've heard or dealt w this Trane coil issue. What is your superheat at vs. Where it's supposed to be? If you have a high superheat, it's for sure your TXV is not...
-
09-12-2011, 05:38 PM
Thread: air handler in garage,dripping?
by Chief FFS- Replies
- 11
- Views
- 469
No, it is not normal to have a unit drip from the...
No, it is not normal to have a unit drip from the underbelly. I've seen units undercharged that have formed ice on the air handler cabinet and when it thawed out, dripped like that...but in my...
-
09-12-2011, 01:38 PM
Thread: air handler in garage,dripping?
by Chief FFS- Replies
- 11
- Views
- 469
Condensation
Your unit either wasn't installed level or there is a crack in the built in drain pan. Put a level on it and see if it's level. If not, that would explain the condensation dripping to a side as...
-
09-12-2011, 12:23 PM
Thread: air handler in garage,dripping?
by Chief FFS- Replies
- 11
- Views
- 469
Not so normal. Any pictures?
Not so normal. Any pictures?
-
09-12-2011, 11:52 AM
Thread: air handler in garage,dripping?
by Chief FFS- Replies
- 11
- Views
- 469
Condensate
It is normal to get condensation coming from the coil. What's not normal is dripping that condensation into the garage. Yes you should have a secondary drip pan under the coil. Also, I am curious...
-
Stat Wire
There is not point operationg the 2 stage Rheem furnace without the proper thermostat. If you don't have enough thermostat wire, you can have them run a addawire kit or re-run T-stat wire. If you...
-
09-12-2011, 11:43 AM
- Replies
- 11
- Views
- 857
R-22
Technically, you can't get R-22 units. What you would be receiving is a Nitrogen charged unit that will need to be charged according to lineset length. Energy Star recommends replacing your equipment...
-
05-02-2011, 07:33 PM
- Replies
- 25
- Views
- 5,035
Where I come from, this doesn't count as a Wall...
Where I come from, this doesn't count as a Wall of Pride photo. What's with the wood support under the air handler?
-
03-02-2011, 11:23 PM
Thread: UV Lights for HVAC System
by Chief FFS- Replies
- 45
- Views
- 17,595
In my opinion, UV lights are best installed by...
In my opinion, UV lights are best installed by the coil. Unless you have a variable speed blower motor that can run on circulate, the air travels too fast across the light to be effective on a whole...