Search:

Type: Posts; User: AllStateTech

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    13
    Views
    1,122

    Where is the lineset going? Is the condenser...

    Where is the lineset going? Is the condenser above or below the a/h


    Sent from my iPhone using Tapatalk
  2. Checkout elite software rhvac very good program...

    Checkout elite software rhvac very good program to use a bit price
  3. It's supposed to cool all the time;)

    It's supposed to cool all the time;)
  4. Replies
    47
    Views
    2,845

    Yeah like many things on cond unit....i mean for...

    Yeah like many things on cond unit....i mean for real cheap ypull get a 3 ton no safeties just barebone but youll end up paying down the road...thats what i hear on recips their good but not...
  5. Replies
    47
    Views
    2,845

    Yeah it makes sense on places that have funny...

    Yeah it makes sense on places that have funny voltage but i too am curious as to why...i know it helps overecome pressure after a system has equallized but do they really help? Is there any data or...
  6. Replies
    14
    Views
    1,196

    Im installing a tempstar unit and because of...

    Im installing a tempstar unit and because of space issues im mounting the txv outside the cabinet as well as the equalizing line. Im going to insulate it as always. On pipes smaller than 7/8 the bulb...
  7. Replies
    10
    Views
    530

    Use an aed much easier!

    Use an aed much easier!
  8. Replies
    19
    Views
    1,145

    It could hypothetically cause a large pressure...

    It could hypothetically cause a large pressure drop..i wouldnt just another place a restriction could occur
  9. Replies
    5
    Views
    428

    I guess i didnt mean converting just using a 410...

    I guess i didnt mean converting just using a 410 coil and a 22 txv
    Brcause the custome doesnt want to pay for a 410 system
  10. Replies
    5
    Views
    428

    Txv mounting

    Installing a tempstar a/h and converting it from 410 to 22. The issue is that after removing the piston to install the txv there isnt much room to braze in the txv. What are your guys thoughts on...
  11. Replies
    4
    Views
    370

    Meet me there at beer 30!

    Meet me there at beer 30!
  12. Replies
    11
    Views
    867

    Wow...customers do the darnest things

    Wow...customers do the darnest things
  13. Replies
    11
    Views
    867

    Ive seen this when i was in school...for all the...

    Ive seen this when i was in school...for all the super cheapies out there i guess aka hack jobs. The is a company that manufactures sheet metal that screws to the floor joists and creates a duct...
  14. Replies
    8
    Views
    533

    I doubt it would be that significant

    I doubt it would be that significant
  15. Replies
    8
    Views
    533

    When i see stuff like that or sometimes it...

    When i see stuff like that or sometimes it happens to me (whistle whislte ) i grab my adjustable and round it out best i can...that mighy just be considered a hack job trick!
  16. Replies
    4
    Views
    370

    Dawg you the best! Beers on me

    Dawg you the best! Beers on me
  17. Replies
    15
    Views
    1,037

    I woukd also sand the line vefore testing, you...

    I woukd also sand the line vefore testing, you would be surprised how much temp difference there is on a clean piece of copper. In ny we used to do and energy efficiency testing on units and we found...
  18. Replies
    4
    Views
    370

    First company a/h

    Have an a/h mn: 30vdxo-hp its a 2.5 ton r-22 coil. Its from a very old quote and i cant find the voltage on it, any help is appreciated. Is there any one site a tech can sign up for to have acess to...
  19. Thread: TXV???

    by AllStateTech
    Replies
    28
    Views
    3,214

    Rundawg can you send me that info as well please...

    Rundawg can you send me that info as well please

    Sent from my SCH-I545 using Tapatalk
  20. Replies
    6
    Views
    489

    I never clicked your profile to check but the...

    I never clicked your profile to check but the proper way would be a one room load calc. Whats the dimensions of the room, how many windows any doors?

    Sent from my SCH-I545 using Tapatalk
  21. Replies
    6
    Views
    489

    Do you know how to do installs? Are you a tech or...

    Do you know how to do installs? Are you a tech or a homeowner? You need to do a load calc

    Sent from my SCH-I545 using Tapatalk
  22. Thread: r22

    by AllStateTech
    Replies
    7
    Views
    709

    Sent from my SCH-I545 using Tapatalk

    Sent from my SCH-I545 using Tapatalk
  23. Replies
    3
    Views
    356

    Agreed nebeast.. cap tube isnt specific to...

    Agreed nebeast.. cap tube isnt specific to refrigerant bwd11 yet just the design temp and compressor....length of cap tube is impprtabt to achieve the design temp but ive also worked on some units...
  24. Thread: r22

    by AllStateTech
    Replies
    7
    Views
    709

    From what someone told me at the supple house...

    From what someone told me at the supple house their was so much excess they lowered the prices to sell it..people were having a lot of luck with mo99 and nu22 that they stopped buying r22 because it...
  25. Replies
    31
    Views
    3,060

    And the answer is...airflow, is it an ecm...

    And the answer is...airflow, is it an ecm motor....is the plastic still on the filter? Ive seen it before

    Sent from my SCH-I545 using Tapatalk
  26. Replies
    24
    Views
    1,503

    Yeah i assume it woulf be similar to a series a...

    Yeah i assume it woulf be similar to a series a brand sells such as luxaire acclimate etc.... almost anything from home depot is junk st ranger lol

    Sent from my SCH-I545 using Tapatalk
  27. Replies
    24
    Views
    1,503

    Builders Grade Equipment?

    Just thought id share, I was talking to a supply house for a price for a 3 ton temp star r-22 unit, dry charged obviously. The counter guy asked me if i wanted the builders grade condenser or the...
  28. Replies
    14
    Views
    1,142

    Yeah warrenty on the motor their cheap so theyll...

    Yeah warrenty on the motor their cheap so theyll get that...ill get thwm on the ductwork that shoukd fix the problem may add some returns in the room

    Sent from my SCH-I545 using Tapatalk
  29. Replies
    14
    Views
    1,142

    Yeah im going to return and install a 20in return...

    Yeah im going to return and install a 20in return my onky concern was whether or not to add a return in each room as the customer just installed a partition in the common hallway where the return was...
  30. Replies
    14
    Views
    1,142

    Yeah im not sure off hand i jist eyed it but id...

    Yeah im not sure off hand i jist eyed it but id have to run smaller returns to certian rooms im out of space in the common hallway

    Sent from my SCH-I545 using Tapatalk
  31. Replies
    14
    Views
    1,142

    Thats what i was thinking.... shouldnt 15 in be...

    Thats what i was thinking.... shouldnt 15 in be enough for 4 ton? I dont have my ductulator on me...wouldnt the return of the unit need to be made large because evwn of i add a return off the main...
  32. Replies
    14
    Views
    1,142

    What killed the motor long shot haha

    Working on a luxaire unit 3 years old with an ecm motor. Customer says no cooling check high voltage and control voltage and both were present so bad ecm motor....this is a 4 ton unit and the return...
  33. Replies
    25
    Views
    1,461

    Sorry wrong file sent, I would say it keeps a...

    Sorry wrong file sent, I would say it keeps a constant superheat


    Sent from my iPhone using Tapatalk - now Free
  34. Replies
    25
    Views
    1,461

    http://www.greenheck.com/media/pdf/otherinfo/DXCoo...

    http://www.greenheck.com/media/pdf/otherinfo/DXCooling_otherinfo.pdf


    Sent from my iPhone using Tapatalk - now Free
  35. Replies
    25
    Views
    1,461

    So what is your question how does it work? ...

    So what is your question how does it work?


    Sent from my iPhone using Tapatalk - now Free
  36. Replies
    25
    Views
    1,461

    Reversing valve or three way valve it's known by...

    Reversing valve or three way valve it's known by both names


    Sent from my iPhone using Tapatalk - now Free
  37. Replies
    25
    Views
    1,461

    Heat pump Sent from my iPhone using Tapatalk...

    Heat pump


    Sent from my iPhone using Tapatalk - now Free
  38. Replies
    59
    Views
    5,295

    2sac don't scare him out of the field what a pain...

    2sac don't scare him out of the field what a pain in the a** if he only knew


    Sent from my iPhone using Tapatalk - now Free
  39. Replies
    59
    Views
    5,295

    What will happen is called capillary action...

    What will happen is called capillary action google or youtube what it means


    Sent from my iPhone using Tapatalk - now Free
  40. Replies
    11
    Views
    824

    Is the Evap fan spinning the wrong way Sent...

    Is the Evap fan spinning the wrong way


    Sent from my iPhone using Tapatalk - now Free
  41. Replies
    59
    Views
    5,295

    C3 welcome to the real world Sent from my...

    C3 welcome to the real world


    Sent from my iPhone using Tapatalk - now Free
  42. Replies
    11
    Views
    824

    Is the box pulling to temp? Maybe your metering...

    Is the box pulling to temp? Maybe your metering device isn't feeding properly. Check bulb position and make sure copper is clean!


    Sent from my iPhone using Tapatalk - now Free
  43. Replies
    59
    Views
    5,295

    That's where the magnet comes in hand if you...

    That's where the magnet comes in hand if you notice copper isn't magnetic yet the steel stub is so as everyone stated that's where you can use the 45% brazen you can also use stay silver which is a...
  44. Replies
    59
    Views
    5,295

    As long as the wet rags are close enough to the...

    As long as the wet rags are close enough to the compressor you shouldn't have a problem with moisture


    Sent from my iPhone using Tapatalk - now Free
  45. Replies
    59
    Views
    5,295

    Do me a favor and take a magnet to the compressor...

    Do me a favor and take a magnet to the compressor discharge tell me what happens..


    Sent from my iPhone using Tapatalk - now Free
  46. Replies
    59
    Views
    5,295

    You can use wet rags which work great or cool gel...

    You can use wet rags which work great or cool gel as suggested just wrap near the joints and you'll be fine. Make sure your using a decent size Tip depending on the pipe size your brazing.


    Sent...
  47. Replies
    11
    Views
    824

    What type of metering device? Is the evaporator...

    What type of metering device? Is the evaporator clean all fans running?


    Sent from my iPhone using Tapatalk - now Free
  48. Replies
    6
    Views
    636

    So if a damper is power open spring closed that...

    So if a damper is power open spring closed that simply means that when power is applied the damper will open and when there is a loss of power a spring will close it. Now if it's power open power...
  49. Replies
    6
    Views
    636

    Zone dampers???!?!?

    What's up guys I've been trying to learn about some dampers for a while now but don't quite get them. I'm looking to become more proficient with them. I understand there is power open and power close...
  50. Replies
    55
    Views
    3,939

    I'd say its time for a new box, you could always...

    I'd say its time for a new box, you could always check for the basics if you'd think low charge. Check amp draw on startup and compare it to the nameplate. Even if it is low on gas as stated who...
Results 1 to 50 of 176
Page 1 of 4 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech365 Virtual Event