09-25-2010, 03:48 PM
Thread: Lennox combo??
by Joker- Replies
- 6
- Views
- 635
No its rated for 3 tons of cooling. Just make...
No its rated for 3 tons of cooling. Just make sure they give you the certificate showing tax credit certified before paying.
-
09-25-2010, 01:31 PM
Thread: Lennox combo??
by Joker- Replies
- 6
- Views
- 635
Are there any numbers after the XP16-036? ...
Are there any numbers after the XP16-036?
Something like a "XP16-036-230/05" or "XP16-036-230-05"
The last unit with a TXV added to the coil will get the tax credit.
The basic model will... -
09-25-2010, 01:23 PM
- Replies
- 10
- Views
- 1,446
I had an Amana do the same thing to me the other...
I had an Amana do the same thing to me the other day more or less.
-
09-25-2010, 01:15 PM
Thread: NEW TRANE AIR HANDLER SWEATING
by Joker- Replies
- 27
- Views
- 2,352
I told you on another post that they would need...
I told you on another post that they would need to come back and check the charge. 410A has super high head pressure and with a hot house and hot outside some guys are a bit timid about putting the...
-
09-25-2010, 12:51 AM
- Replies
- 66
- Views
- 3,305
Nope. Its hard enough to get the guys to mastic...
Nope. Its hard enough to get the guys to mastic the plenum duct joint. These guys work for many companies and do new construction. They thought I was BSing them when I ask them to seal the joint. I...
-
09-24-2010, 08:13 PM
- Replies
- 66
- Views
- 3,305
Are you joking! Most units are lucky to be...
Are you joking! Most units are lucky to be strapped let alone sealed.
Truth strap both inner and outer then mastic. Never have I ever seen someone mastic inner liner. I have done this by... -
09-24-2010, 11:18 AM
Thread: re: 4TEE3C05A damaged A coil
by Joker- Replies
- 7
- Views
- 426
If you or the installer have registered the units...
If you or the installer have registered the units with Trane it comes with a 10 year parts warranty. If not then it comes with a 5 year warrant.
-
09-23-2010, 11:54 PM
Thread: re: 4TEE3C05A damaged A coil
by Joker- Replies
- 7
- Views
- 426
How did you see the coil since its encased in the...
How did you see the coil since its encased in the air handler?
Sometimes if you have to remove a coil to get in up in the attic. It may get slightly damaged. If the damage is a small % of the coil... -
09-23-2010, 11:46 PM
Thread: NEW TRANE TODAY AND NOT COOLING
by Joker- Replies
- 14
- Views
- 869
If it was very hot in the house when they put it...
If it was very hot in the house when they put it in have them come by and check the system(charge). Hot humid houses are out of the range of design charts which we go by to charge a system. What...
-
09-23-2010, 06:20 PM
Thread: Trane XL 16i - Problem with Heating
by Joker- Replies
- 6
- Views
- 1,551
Whens the last time you had the unit serviced? It...
Whens the last time you had the unit serviced? It may just need to be serviced.
-
09-23-2010, 06:17 PM
Thread: NEW TRANE TODAY AND NOT COOLING
by Joker- Replies
- 14
- Views
- 869
Do you have a 2 stage cooling system? Do you...
Do you have a 2 stage cooling system?
Do you have the model # for the outside? -
09-13-2010, 08:27 PM
Thread: Does 3 Ton XR15 HAVE SOUND BLANKET?
by Joker- Replies
- 7
- Views
- 559
I just put in a 3.5 ton XR 15 today and it did...
I just put in a 3.5 ton XR 15 today and it did have the Jacket and it was very quiet. I explained the unit and all that we had done while standing next to the unit and we did not raise our voices nor...
-
09-13-2010, 12:18 AM
Thread: XR115 vs XL16I Dallas
by Joker- Replies
- 10
- Views
- 800
ARI # 3933740 Active Systems XL16I TRANE ...
ARI # 3933740 Active Systems XL16I TRANE
4TTX6060E1
4TXFH063CZ3
TUD2D120B9V5
Tonnage 55000
eer 13.00
seer 16.00 -
09-12-2010, 05:15 PM
Thread: Re: Concrete Slab Sizing
by Joker- Replies
- 10
- Views
- 1,140
Is the old slab poured in place attached to the...
Is the old slab poured in place attached to the house? That would be the only reason not to change it.
-
09-12-2010, 05:11 PM
- Replies
- 13
- Views
- 1,070
3485824 4TTX5024A1 ...
3485824 4TTX5024A1 4TXCC005CC3 *UD060R9V3** 25800 13.00 15.75
4171107 4TTX5024A1 4TXCC005CC3 *UD2B060A9V3 25800 13.00 15.75
4216920 4TTX5024A1 4TXCC006CC3 ************* ... -
09-12-2010, 04:52 PM
Thread: XR115 vs XL16I Dallas
by Joker- Replies
- 10
- Views
- 800
The XR 15 is a stripped down XLi16 with out 2...
The XR 15 is a stripped down XLi16 with out 2 stages. Be very happy.
As for the filters 4" filter last longer between changing. Its all I sell unless customer ask for 1".
The only down fall is... -
09-11-2010, 03:05 PM
Thread: old furnace replacement
by Joker- Replies
- 3
- Views
- 416
I have on occasions knocked out the back sheet...
I have on occasions knocked out the back sheet rock to get me 3 more inches to make the closet work. Some times you just have to rebuild the closet or move the furnace to the attic.
I don't know... -
09-11-2010, 02:57 PM
Thread: efficiency comparisons 14 vs 16 SEER
by Joker- Replies
- 14
- Views
- 25,897
Not sure if this is what you wanted but here it...
Not sure if this is what you wanted but here it is
[(new seer - old seer) div old seer ] * 100% equals the percentage of savings in cooling mode of energy consumed by a/c. This does not mean the... -
09-11-2010, 02:45 PM
Thread: Heat pump/duel fuel question
by Joker- Replies
- 42
- Views
- 1,589
Problem is during cooling the furnace heat...
Problem is during cooling the furnace heat exchanger is open to air from the other side of the blower conditioned air you breath. The open air opposite conditioned air will sweat and ruin your heat...
-
09-11-2010, 02:23 PM
Thread: Heat pump/duel fuel question
by Joker- Replies
- 42
- Views
- 1,589
:ditto:
:ditto:
-
08-31-2010, 01:27 PM
Thread: Low cfm fan for small attic space
by Joker- Replies
- 3
- Views
- 438
Just a cheap fart fan pumps about 65-100 CFM....
Just a cheap fart fan pumps about 65-100 CFM. Granger will have all you need.
-
08-30-2010, 10:53 PM
- Replies
- 7
- Views
- 2,089
To sweat in a TXV is no easy task. You can change...
To sweat in a TXV is no easy task. You can change just the TXV.
I had to replace a Trane evaporator coil once and the cost of the replacement evaporator coil was more expensive than buying the... -
08-30-2010, 12:10 AM
Thread: ?? about restrictions.
by Joker- Replies
- 7
- Views
- 402
:rules: I guess the first statement threw me...
:rules:
I guess the first statement threw me off! LOL
Sorry for not reading the whole thing before commenting. -
08-29-2010, 08:09 PM
Thread: ?? about restrictions.
by Joker- Replies
- 7
- Views
- 402
What if the restriction is in the condenser unit?...
What if the restriction is in the condenser unit?
Then it would cause the low pressure to back up giving a high low pressure.
I have seen this with my own eyes. Not very common problem. Most... -
08-29-2010, 06:31 PM
Thread: Fluorescent Dye or Sniffer?
by Joker- Replies
- 34
- Views
- 1,418
I had the H-10. It was ok. I have had probably 6...
I had the H-10. It was ok. I have had probably 6 really nice detectors in my life time as a tech. I could find leaks but not exactly. I am a stickler for wanting to see exactly where the leak is. "In...